Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Retrograde Cholangiopancreatography AI Assisted System Validation on Effectiveness and Safety

20 de janeiro de 2021 atualizado por: Renmin Hospital of Wuhan University

A Multicentric Validation Study on the Effectiveness and Safety of Artificial Intelligence Assisted System in Clinical Application of Retrograde Cholangiopancreatography

In this study, the investigators proposed a prospective study about the effectiveness of artificial intelligence system for Retrograde cholangiopancreatography. The subjects would be include in an analyses groups. The AI-assisted system helps endoscopic physicians estimate the difficulty of Endoscopic retrograde cholangiopancreatography for choledocholithiasis and make recommendations based on guidelines and difficulty scores. The investigators used the stone removal times, success rate of stone extraction and Operating time to reflect the difficulty of the operation, and evaluated whether the results of the AI system were correct.

Visão geral do estudo

Descrição detalhada

Endoscopy is a routine and reliable method for the diagnosis of digestive tract diseases.Common endoscopy are gastroscopy, colonoscopy, capsule endoscopy and enteroscopy, ultrasonic gastroscopy, after ercp and other related technology, can be used in early gastric cancer and peptic ulcer, esophageal varices, the stomach before lesion, intestinal polyps and adenomas and colorectal lesions, inflammatory bowel disease, pancreas disease, biliary tract disease diagnosis and follow-up.At present, digestive endoscopy almost covers the diagnosis of the vast majority of diseases of the digestive tract, and diseases of the digestive system that cannot be directly seen by endoscopy can also be realized through endoscopic-based technologies such as endoscopy and ERCP (here the investigators collectively refer to endoscopy), so as to achieve the coverage of the whole digestive system.It can be seen that digestive endoscopy is of great significance for the diagnosis of digestive diseases and the development of digestive field.

With the popularization of these related technologies, the number of endoscopy increased rapidly, which further increased the workload of endoscopists. The operation of endoscopy by high-load endoscopists would reduce the quality of endoscopy, which is prone to problems such as incomplete examination coverage and incomplete detection of lesions.In digestive endoscopy, there are some problems in China, such as lack of endoscopic physicians and uneven distribution, and the quality of endoscopy is not up to standard. These problems need to be solved urgently in order to relieve the pain of patients, save medical resources, save the time and money of patients, and ensure the quality of patients' medical treatment.

In 2015, the proposal of deep learning brought great changes to the field of artificial intelligence, which made the development of artificial intelligence leap to a new level.Computer vision is a science that studies how to make machines "see". Through deep learning, camera and computer can replace human eyes to carry out machine vision such as target recognition, tracking and measurement.Interdisciplinary cooperation in the field of medical imaging and computer vision is also one of the research hotspots in recent years. At present, it is mainly applied to the automatic identification and detection of lesions and quality control, and has achieved good results. It can assist doctors to find lesions, make disease diagnosis and standardize doctors' operations, so as to improve the quality of doctors' operations.With mature technical support, it has a good prospect and application value to develop endoscopic operating system for lesion detection and quality control based on artificial intelligence methods such as deep learning.

In this study, the investigators proposed a prospective study about the effectiveness of artificial intelligence system for Retrograde cholangiopancreatography. The subjects would be include in an analyses groups. The AI-assisted system helps endoscopic physicians estimate the difficulty of Endoscopic retrograde cholangiopancreatography for choledocholithiasis and make recommendations based on guidelines and difficulty scores. The investigators used the stone removal times, success rate of stone extraction and Operating time to reflect the difficulty of the operation, and evaluated whether the results of the AI system were correct.

Tipo de estudo

Observacional

Inscrição (Antecipado)

150

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Hubei
      • Wuhan, Hubei, China, 430000
        • Renmin Hospital
    • Shanghai
      • Shanghai, Shanghai, China, 200433
        • Changhai Hospital
      • Shanghai, Shanghai, China, 200072
        • People'S Hospital

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos e mais velhos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Método de amostragem

Amostra Não Probabilística

População do estudo

Patients who meet the admission criteria for endoscopic examination.

Descrição

Inclusion Criteria:

  • Who needs ERCP and its related tests are needed to further define the characteristics of digestive tract diseases
  • Able to read, understand and sign informed consent
  • The investigator believes that the subject can understand the process of the clinical study, is willing and able to complete all the study procedures and follow-up visits, and cooperate with the study procedures
  • Patients with a natural duodenal papilla

Exclusion Criteria:

  • Has participated in other clinical trials, signed informed consent and is in the follow-up period of other clinical trials
  • Has drug or alcohol abuse or mental disorder in the last 5 years
  • Women who are pregnant or lactating
  • Subjects with previous biliary sphincterotomy
  • The investigator determined that subjects were not suitable for ERCP and related tests
  • A high-risk disease or other special condition that the investigator considers inappropriate for the subject to participate in a clinical trial
  • Patients with known more severe pancreatic head carcinoma
  • Patients with acute pancreatitis within 3 days
  • Biliary stent replacement or removal did not occur after pancreatic angiography as expected
  • Acute cardiovascular and cerebrovascular diseases

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Modelos de observação: Outro
  • Perspectivas de Tempo: Prospectivo

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Number of stone removal operations
Prazo: A year
The number of times that the stoning balloon and the stoning net were pulled out of the lumen during the stoning process.
A year

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
the accuracy of the measurement
Prazo: A year
The diameter of the stone (or the width of the lower end of the bile duct) measured by the machine is consistent with the doctor's degree.Accurate DuDu = | machine measurement results - the doctor gold standard measurement results | / doctor gold standard measurements.
A year
Stone clearance success rate
Prazo: A year
Whether the stones have been removed successfully
A year
the sensitivity of the prediction of the stone
Prazo: A year
That is, the sensitivity of the machine to predict the number of stones.Sensitivity = the number of calculi correctly predicted by the machine/the number of actual calculi.
A year
the operate time
Prazo: During surgery
Refers to the time from the successful intubation of the duodenal papilla guide wire to the beginning of endoscopic withdrawal.
During surgery
the removal stone time
Prazo: During surgery
Refers to the time from the successful intubation of the duodenal papilla guide wire to the beginning of endoscopic withdrawal.
During surgery

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Investigadores

  • Investigador principal: Honggang Yu, Doctor, Wuhan University Renmin Hospital

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

1 de setembro de 2020

Conclusão Primária (Antecipado)

1 de julho de 2021

Conclusão do estudo (Antecipado)

31 de dezembro de 2021

Datas de inscrição no estudo

Enviado pela primeira vez

15 de janeiro de 2021

Enviado pela primeira vez que atendeu aos critérios de CQ

20 de janeiro de 2021

Primeira postagem (Real)

22 de janeiro de 2021

Atualizações de registro de estudo

Última Atualização Postada (Real)

22 de janeiro de 2021

Última atualização enviada que atendeu aos critérios de controle de qualidade

20 de janeiro de 2021

Última verificação

1 de janeiro de 2021

Mais Informações

Termos relacionados a este estudo

Palavras-chave

Outros números de identificação do estudo

  • EA-19-006-08

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever