Peritoneal Transport With a New Bicarbonate-based Peritoneal Dialysis Solution Compared to Conventional Solution.

2 de junho de 2026 atualizado por: Olof Heimburger, Karolinska Institutet
Cross-over study. Patients treated with peritoneal dialysis are investigated twice with a single 4h dwell study: once with Bicarbonate-Lactate solution as buffer (Physioneal TM) and once with conventional lactate PD solution (Dianeal TM). Radioidinated human serum albumin is used as a volume marker to assess ultrafiltration and frequent dialysis and blood sampling to assess peritneal transport of solutes and pH changes.

Visão geral do estudo

Descrição detalhada

Patients treated with peritoneal dialysis (PD)are investigated twice of different days with a single 4h dwell study: once with solution with a solution with bicarbonate 15 mmol/L abd Lactate 15 mmol/L as buffer (Physioneal TM) and once with conventional lactate-buffered (40 mmol/L) PD solution (Dianeal TM). Aproximately 2 liter of PD solution was infused each time. Intraperitoneal fluid was sampled during the dwell at t = 0, 3, 6, 10, 15, 20, 25, 30, 40, 50, 60, 90, 120, 180, and 240 minutes from the end of the dialysis fluid infusion and the start of the peritoneal dwell. Venous blood samples were drawn from the patient before the start of the dwell and at t = 15, 60, 120, 240 minutes.

New and spent dialysate bags were weighed before and after each dwell to assess infused and drain volumes, respectively; the volumes were adjusted for the weight of the empty bags. Radio-iodinated serum albumin (RISA) added to the solutions before infusion was used as volume marker to estimate intraperitoneal volume. The residual volume (after the previous dwell) was calculated from the dilution of the marker upon infusion of fresh dialysate; after the dwell the peritoneal cavity was rinsed with 1 liter of solution (glucose 1.36%) in order to estimate post-drain residual volume.

Ultrafiltration volume was calculated from the changes in intraperitoneal volume (using 3 minutes after infusion as reference) and corrected for volumes of taken samples. The rate of peritoneal absorption was estimated from the disappearance of the marker from the peritoneal cavity].

The composition of the pre-dialysis (residual) fluid was assessed based on the sample taken from the spent dialysate from the previous dwell.

Concentrations of urea, creatinine, glucose, phosphate, chloride, and lactate, in plasma and dialysate, were measured by Monarch 1000 (Instrumentation Laboratory, MA), while flame photometry was used for sodium and potassium. Dialysate pH was measured with a pH meter. The concentrations of calcium, CO2, bicarbonate, and plasma pH were measured by AVL OMNI Combi Blood Gas Analyzer (AVL, Graz, Austria). The plasma concentrations of glucose, sodium, urea, creatinine, potassium, chloride, and phosphate were corrected for plasma water fraction. Creatinine measurements in dialysate were corrected for glucose concentration. Albumin and beta-2 microglobulin (B2M) concentration were measured with immunological methods.

Advanced mathematical modelling is used to analyze the results and tgo asses transport parameters.

Tipo de estudo

Intervencional

Inscrição (Real)

7

Estágio

  • Fase 3

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

      • Stockholm, Suécia, S-141 86
        • Research unit, renal medicine

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Descrição

Inclusion Criteria:

  • patient treated with peritoneal dialysis in a clinically stable condition

Exclusion Criteria:

  • none

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Outro
  • Alocação: Não randomizado
  • Modelo Intervencional: Atribuição cruzada
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Bicarbonate lactate solution investigatd first
The patients were studied with the bicarbonate-lactate solution the first study day and with conventional lactate.based solution on a later day.
All patients were studied twice with a 4-h dwell study (one peritoneal dialysis dwell) about 7 days apart. The two arms represent different order of the used periteonal dialysis fluid for the two dwell studies.
Experimental: Lactate solution investigated first
The patients were studied with the conventional lactate.based solution the first study day and with bicarbonate-lactate solution on a later day.
All patients were studied twice with a 4-h dwell study (one peritoneal dialysis dwell) about 7 days apart. The two arms represent different order of the used periteonal dialysis fluid for the two dwell studies.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Difference in net ultrafiltration (ml)
Prazo: 4 hours
Assessment of fluid transport during a PD dwell. Intraperitoenal volume changes during the 4 hour dwells will be assesed from dilution of the added volume marker with correction for absorption of the marker. Amount of marker remaining in the drained fluid after four hours will be subratcted from the initial added amount to calculate amount of marker absorbed during the dwell. Residual volumes before and after the dwell can also be calculated from dilution of the marker. This makes it possible to calculate the intraperitoneal volume of time curve during the dwell and net ultrafiltration (=net fluid removal). To simplify, the intraperitoneal volume (ml) at 240 minutes of the dwell minus the intraperitoneal volume after infusion of the dialysis fluid.
4 hours

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Changes to acid-base homeostasis
Prazo: 4 hours
Assessment of pH, concentrationa of bicarbonate and lactate i dialysate and plasma. Frequent dialysate sampling will be used and plasma levels will be assessed mutiple times. For each solute, the mass removed/absorbed will be calculated as the difference between the dialysate mass the end of the dwell (dialysate concentration times dialysate volume, corrected for total volume of samples) and mass immediately after infusion of fresh dialysate. The latter is calculated adding up the mass in residual and infused fluids. As the conventional lactate-buffered solution is acidic (pH 5.3) and the bicarbonate-lactate buffered solution is neutral (pH 7.4) the difference in pH between the solutions over time of the dwell may be described.
4 hours
Differences in small solute transport
Prazo: 4 hours
Frequent dialysate sampling will be used and plasma levels will be assessed mutiple times for several small solutes. For each solute, the mass removed/absorbed will be calculated as the difference between the dialysate mass the end of the dwell (dialysate concentration times dialysate volume, corrected for total volume of samples) and mass immediately after infusion of fresh dialysate. The latter is calculated adding up the mass in residual and infused fluids. As the conventional lactate-buffered solution is acidic (pH 5.3) and the bicarbonate-lactate buffered solution is neutral (pH 7.4) it makes it possible to assess if pH affects transport characteristics of other solutes, in particular small solutes (Na, K, Ca, bicarbonate, lactate, creatinine, urea).
4 hours
Differences in protein transport
Prazo: 4 hours
Frequent dialysate sampling will be used and plasma levels will be assessed mutiple times for several small solutes. For each solute, the mass removed/absorbed will be calculated as the difference between the dialysate mass the end of the dwell (dialysate concentration times dialysate volume, corrected for total volume of samples) and mass immediately after infusion of fresh dialysate. The latter is calculated adding up the mass in residual and infused fluids. As the conventional lactate-buffered solution is acidic (pH 5.3) and the bicarbonate-lactate buffered solution is neutral (pH 7.4) it makes it possible to assess if pH affects transport characteristics of proteins (albumin and beta-2-microglobuline).
4 hours

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

9 de setembro de 1997

Conclusão Primária (Real)

13 de novembro de 1997

Conclusão do estudo (Real)

13 de novembro de 1997

Datas de inscrição no estudo

Enviado pela primeira vez

12 de maio de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

29 de maio de 2026

Primeira postagem (Real)

2 de junho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

4 de junho de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

2 de junho de 2026

Última verificação

1 de maio de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

INDECISO

Descrição do plano IPD

This study was performed almost 30 years ago. A reasonalbe request for data sharing will be considered as stated in the publications from the study

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

produto fabricado e exportado dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever