Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Comparison of Reliability, Time Cost, and Participant Comfort of Lymphedema Assessments in Upper Extremity

4 de novembro de 2026 atualizado por: Burak Ertürk, Karadeniz Technical University

Comparison of Reliability, Time Cost, and Participant Comfort of Volumetric, Circumference Measurement, LiDAR, and 3D Modeling Methods in Upper Extremity Volume Measurement

This study aims to evaluate and compare the measurement reliability, total time cost (preparation, acquisition, post-processing), and participant comfort of conventional limb volume measurement methods (water displacement volumetry, tape-based circumference measurement) against modern digital techniques (LiDAR-based mobile scanning, stereophotogrammetric 3D optical scanning) in the upper extremity. The evaluation will be conducted on both healthy adults and patients diagnosed with upper extremity lymphedema. Additionally, the impact of assessor experience on digital data post-processing and the sensitivity of the methods to detect small localized volume increases using a simulated edema model (50 mL) will be investigated.

Visão geral do estudo

Descrição detalhada

Upper extremity lymphedema is a chronic and progressive condition characterized by the accumulation of protein-rich interstitial fluid, leading to tissue fibrosis and structural volume increases. Precise, reliable, and practical limb volume measurement is vital for diagnosis, staging, and therapeutic monitoring. While water displacement volumetry remains the gold standard, it poses practical challenges including cross-contamination risks, prolonged setup, and inapplicability to patients with wounds or severe limitations. Circumference tape measurement with frustum modeling is widely used but suffers from high examiner dependency and geometric approximation errors. Emerging non-contact technologies, such as mobile Light Detection and Ranging (LiDAR) sensors and optical 3D surface scanning, offer rapid, hygienic, and objective alternatives. However, gaps remain regarding their sensitivity to subclinical volume variations, the influence of post-processing operator experience, procedural time costs, and participant burden.

This methodological, comparative, cross-sectional pilot study evaluates upper extremity volume assessment methods across two cohorts: healthy adults (n = 40) and individuals clinically diagnosed with upper extremity lymphedema (n = 24). Measurements are conducted on the dominant upper extremity in healthy participants and on the affected upper extremity in patients with lymphedema, demarcated from the ulnar styloid process to 2-3 cm distal to the axilla.

All participants undergo the following sequentially:

  1. Water Displacement Volumetry: Conducted using a custom overflow tank and precision graduated cylinders as the reference standard. The hand volume is measured first and subtracted from the full-arm immersion volume. Strict decontamination protocols are applied between sessions.
  2. Circumference Measurement: Circumferential measures are taken at 4 cm intervals in a supine position and converted to limb volume using the truncated cone (Kuhnke/Frustum) formula. Measurements are obtained independently by both an experienced and an inexperienced evaluator.
  3. LiDAR-Based Scanning: Acquired using an iPad equipped with Structure Sensor 3 (Structure application). Standardized positioning is utilized with adhesive anatomical landmarks.
  4. Photogrammetric/Optical 3D Scanning: Acquired using the Creality Raptor X 3D scanner (Creality Scan software).

To address operator dependency in digital workflows, raw 3D point-cloud processing, mesh trimming, and volumetric integration are performed under a blinded protocol by both an experienced operator and an inexperienced operator.

In the healthy adult cohort, a simulated localized edema protocol is additionally conducted to determine method sensitivity to small volume fluctuations. A non-absorbent medical silicone pad (calibrated to exactly 50 mL via prior water volumetry) is affixed to the participant's forearm, after which circumference, LiDAR, and 3D optical scanning procedures are repeated.

Comprehensive time-motion analyses are recorded with a digital stopwatch across three distinct phases for each modality: equipment preparation, data acquisition, and post-processing computation. Participant-reported outcomes, including physical discomfort and fatigue, are documented using a Visual Analog Scale (VAS, 0-100 mm) immediately after each test and ranked comparatively at session conclusion.

Tipo de estudo

Observacional

Inscrição (Estimado)

64

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos a 65 anos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Sim

Gêneros Elegíveis para o Estudo

Tudo

Método de amostragem

Amostra Não Probabilística

População do estudo

Healthy adult volunteers and clinical patients diagnosed with upper extremity lymphedema evaluated at the physical therapy and rehabilitation laboratories.

Descrição

Inclusion Criteria:

Healthy Volunteers:

  • Aged between 18 and 65 years
  • Voluntarily willing to participate and providing written informed consent
  • Absence of any known musculoskeletal or neuromuscular deformity, active edema, open wounds, or history of major upper extremity surgery

Lymphedema Patients:

  • Aged between 18 and 65 years
  • Voluntarily willing to participate and providing written informed consent
  • Confirmed clinical diagnosis of upper extremity lymphedema
  • Absence of active skin lesions, open ulcerations, acute cellulitis, or lymphorrhea on the affected upper extremity

Exclusion Criteria (Both Groups):

  • Presence of open wounds, acute skin breakdown, lymphorrhea, active cutaneous infection (cellulitis, fungal infection), or severe dermatological lesions on the tested limb
  • Severe cognitive, systemic, or physical limitations preventing standard testing positioning (supine posture or holding the limb steady) or safe water immersion
  • Known severe skin allergy or dermatological hypersensitivity to silicone or adhesive fixation materials (for the healthy cohort undergoing the simulated edema protocol)

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Modelos de observação: COHORT
  • Perspectivas de Tempo: CROSS_SECTIONAL

Coortes e Intervenções

Grupo / Coorte
Healthy Adults

Forty healthy adult volunteers aged 18 to 65 years with no known deformity, edema, open wound, or prior surgical history in the upper extremity. Participants undergo baseline upper extremity volume assessments on their dominant arm using water displacement volumetry, tape-based circumference measurement (performed independently by experienced and inexperienced evaluators), LiDAR-based scanning (Structure Sensor 3), and stereophotogrammetric 3D optical scanning (Creality Raptor X). Additionally, to determine method sensitivity to small volume fluctuations, participants undergo a simulated edema protocol wherein a calibrated 50 mL non-absorbent medical silicone pad is affixed to the forearm, followed by repeat circumference, LiDAR, and 3D optical scans.

Patients with Lymphedema

Twenty-four adult individuals aged 18 to 65 years clinically diagnosed with upper extremity lymphedema, without active skin lesions, open wounds, or lymphorrhea on the affected limb. Participants undergo upper extremity volume measurements on their affected arm using water displacement volumetry, tape-based circumference measurement (performed independently by experienced and inexperienced evaluators), LiDAR-based scanning (Structure Sensor 3), and stereophotogrammetric 3D optical scanning (Creality Raptor X). The simulated edema protocol is not applied to this cohort.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Upper Extremity Limb Volume
Prazo: Assessed during the single cross-sectional experimental testing session (approximately 1 to 2 hours per participant).

Total upper extremity limb volume (measured in milliliters, mL) evaluated across four measurement modalities: water displacement volumetry (gold standard reference), circumference tape measurement (calculated using the truncated cone / Frustum formula), LiDAR-based scanning (Structure Sensor 3), and stereophotogrammetric 3D optical scanning (Creality Raptor X). Measurement agreement and reliability will be determined using the Intraclass Correlation Coefficient (ICC Model 3,1) and Bland-Altman limits of agreement. Digital 3D model post-processing and tape measurements will be evaluated comparatively between experienced and inexperienced assessors.

Assessed during the single cross-sectional experimental testing session (approximately 1 to 2 hours per participant).

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Procedural Time Cost (Process Duration)
Prazo: Throughout the 4-hour experimental protocol window (from 1 hour prior to participant arrival, during the 2-hour assessment session, through 1 hour following participant departure)

Total time cost (measured in minutes and seconds using a digital stopwatch) required for each modality, tracked across three distinct phases: preparation time (equipment setup, sanitation, and participant positioning), data acquisition time (actual measurement/scanning), and analysis/post-processing time (mathematical formula calculation or digital point-cloud cropping and mesh volume computation).

Throughout the 4-hour experimental protocol window (from 1 hour prior to participant arrival, during the 2-hour assessment session, through 1 hour following participant departure)
Participant-Perceived Discomfort and Fatigue
Prazo: Immediately after each measurement procedure and at the end of the visit (within 2 hours)

Participant-reported physical discomfort and fatigue assessed immediately following each measurement modality using a Visual Analog Scale (VAS, 0 to 10 cm, where 0 represents 'no discomfort/fatigue' and 10 represents 'extreme discomfort/fatigue'). Overall method preference and willingness to repeat the procedure will be ranked at the conclusion of all tests.

Immediately after each measurement procedure and at the end of the visit (within 2 hours)
Sensitivity to Localized Small Volume Changes (Simulated Edema Absolute Error)
Prazo: Immediately following baseline measurements during the single study visit (at approximately 1 hour post-baseline)

Absolute measurement error (calculated in milliliters, mL) in detecting an artificial, localized 50 mL volume increase. In the healthy adult cohort, a calibrated, non-absorbent medical silicone pad (50 mL verified via water displacement) is affixed to the forearm. The error is determined as the absolute difference between the volume change detected by circumference tape, LiDAR, and 3D optical scanning and the true 50 mL volume of the pad.

Immediately following baseline measurements during the single study visit (at approximately 1 hour post-baseline)

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Investigadores

  • Investigador principal: Burak Erturk, PT, PhD, Karadeniz Technical University

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Publicações Gerais

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

1 de fevereiro de 2027

Conclusão Primária (Estimado)

1 de fevereiro de 2028

Conclusão do estudo (Estimado)

1 de junho de 2028

Datas de inscrição no estudo

Enviado pela primeira vez

30 de outubro de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

4 de novembro de 2026

Primeira postagem (Real)

6 de novembro de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

6 de novembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

4 de novembro de 2026

Última verificação

1 de outubro de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Descrição do plano IPD

Individual participant data will not be shared publicly because this investigation constitutes the foundational baseline phase of a multi-stage longitudinal research project. The acquired normative volumetric, photographic, and point-cloud datasets will be actively utilized as prospective control and benchmark data in subsequent interrelated clinical and technological validation phases.

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever