Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

CO2-Patterns During Hyperoxia and Physical Exercise in COPD

13 июля 2021 г. обновлено: Klaus Kenn, Schön Klinik Berchtesgadener Land

CO2-Patterns During Hyperoxia and Physical Exercise in People With Severe COPD - a Randomized, Double-blind Cross Over Trial

The aim of the study is to investigate a possible correlation between the change in PCO2 during a hyperoxia-test and the change in PCO2 during walking in people with COPD

Обзор исследования

Статус

Рекрутинг

Условия

Подробное описание

Rationale:

Carbon dioxide partial pressure (PCO2) varies significantly in patients with advanced chronic obstructive pulmonary disease (COPD). Data from the Swedish LTOT Registry showed that PCO2 is an independent predictor for mortality and that there is a U-shaped relationship. Patients with advanced COPD who are still normocapnic at rest may still develop a clinically relevant, exercise-induced carbon dioxide (CO2) retention during exercise/ activity. It is also known that altered breathing patterns at night in COPD patients can lead to nocturnal hypercapnia, especially during REM sleep. The course of PCO2 cannot be reliably predicted by lung function parameters or resting blood gas analysis. Since exercise tests with blood gas control or nightly PCO2 monitoring are rarely performed in clinical routine, exercise induced CO2 retention often remains undetected. In the literature, there is little information on PCO2 behaviour under everyday conditions (with or without LTOT) such as rest, physical exertion and nightly sleep. Therefore, predictors that could describe the PCO2 patterns are missing. However, one former study by O'Donnel from 2002 showed that the change in CO2 under hyperoxia conditions could provide predictive information for the change in CO2 with exercise.

Objective:

Primary aim of this study is to investigate whether the change of PCO2 during a hyperoxia-test (10l/min O2 at rest) correlates with the change of PCO2 during walking exercise with either a: l/min O2 as prescribed; b: medical air; c: 10l/min O2.

Design:

This study is a randomized, controlled cross-over trial. Following an initial maximal incremental shuttle walk test (ISWT), the participant will perform 3 endurance shuttle walk tests (ESWT) at 85% of the maximum ISWT pace on three consecutive days (24h break between ESWTs). In a randomized order, participants will perform one ESWTs with O2-flow as prescribed (e.g. study day 1), one with medical air (same flow rate as prescribed oxygen) (e.g. study day 2) and one with 10l/min O2 (e.g. study day 3). An additional hyperoxia test (10l/min O2 for ten minutes; at resting condition) will be perfomed on each day prior to performing an ESWT.

Тип исследования

Интервенционный

Регистрация (Ожидаемый)

55

Фаза

  • Непригодный

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Контакты исследования

  • Имя: Tessa Schneeberger
  • Номер телефона: +498652931540 +498652931540
  • Электронная почта: TSchneeberger@Schoen-Klinik.de

Места учебы

      • Schönau am Königssee, Германия, 83471
        • Рекрутинг
        • Klinikum Berchtesgadener Land, Schön Kliniken
        • Контакт:

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

  • Ребенок
  • Взрослый
  • Пожилой взрослый

Принимает здоровых добровольцев

Нет

Полы, имеющие право на обучение

Все

Описание

Inclusion Criteria:

  • COPD III/ IV
  • 35mmHg < PCO2 <= 55mmHg (under resting conditions, breathing room air)
  • Hypoxemia (PaO2<60mmHg) under room air conditions (rest or during exercise) or SpO2 <88% during exercise
  • established oxygen therapy or given indication for oxygen therapy
  • written informed consent

Exclusion Criteria:

  • acute exacerbation of COPD
  • exercise limiting cardiac or orthopedic comorbidites
  • PaO2 <50mmHg at rest, breathing room air

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Уход
  • Распределение: Рандомизированный
  • Интервенционная модель: Назначение кроссовера
  • Маскировка: Двойной

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Экспериментальный: Randomised to begin with oxygen-supplementation at 10L/min during ESWT
Randomised order of tests starting with the 10L/min O2, during the ESWT followed by prescribed O2 flow rate or medical air in randomised order on seperate days
Supplemental O2 at rest of 10 l/min for ten minutes followed by supplemental O2 at the prescribed exercise O2-flow rate during ESWT.
Supplemental O2 at rest of 10 l/min for ten minutes followed by medical Air at prescribed O2 flow rate during ESWT.
Supplemental O2 at rest of 10 l/min for ten minutes followed by 10L/min O2 during ESWT.
Экспериментальный: Randomised to begin with medical air supplementation at prescibed O2 flow rate during ESWT
Randomised order of tests starting with the medical air during the ESWT followed by prescribed O2 flow rate or 10L/min O2 in randomised order on seperate days
Supplemental O2 at rest of 10 l/min for ten minutes followed by supplemental O2 at the prescribed exercise O2-flow rate during ESWT.
Supplemental O2 at rest of 10 l/min for ten minutes followed by medical Air at prescribed O2 flow rate during ESWT.
Supplemental O2 at rest of 10 l/min for ten minutes followed by 10L/min O2 during ESWT.
Экспериментальный: Randomised to begin with oxygen supplementation at prescibed O2 flow rate during ESWT
Randomised order of tests starting with the prescribed O2 flow rate, during the ESWT followed by 10L/min O2 or medical air in randomised order on seperate days
Supplemental O2 at rest of 10 l/min for ten minutes followed by supplemental O2 at the prescribed exercise O2-flow rate during ESWT.
Supplemental O2 at rest of 10 l/min for ten minutes followed by medical Air at prescribed O2 flow rate during ESWT.
Supplemental O2 at rest of 10 l/min for ten minutes followed by 10L/min O2 during ESWT.

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Change in PCO2 during hyperoxia at rest
Временное ограничение: Change from baseline to after 10 minutes breathing 10L/min oxygen
pCO2 measured by capillary blood gases taken before and after the hyperoxia test
Change from baseline to after 10 minutes breathing 10L/min oxygen
Change in PCO2 from rest to end exercise (endurance shuttle walk test)
Временное ограничение: Change from baseline to the end of the ESWT, up to 20 minutes
pCO2 measured by capillary blood gases taken before and after the ESWT
Change from baseline to the end of the ESWT, up to 20 minutes

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Transcutaneous partial pressure of CO2 (TcPCO2) during hyperoxia test
Временное ограничение: Continuously from baseline to 10 minutes breathing 10L/min oxygen
TcPCO2 measured by continuous transcutaneous recording via Sentec-Digital Monitor® (Sentec, Therwil, Switzerland)
Continuously from baseline to 10 minutes breathing 10L/min oxygen
Transcutaneous partial pressure of CO2 (TcPCO2) during endurance shuttle walk test
Временное ограничение: Continuously during ESWT, up to 20 minutes
TcPCO2 measured by continuous transcutaneous recording via Sentec-Digital Monitor® (Sentec, Therwil, Switzerland)
Continuously during ESWT, up to 20 minutes
Breathing frequency during hyperoxia test
Временное ограничение: Continuously from baseline to 10 minutes breathing 10L/min oxygen
Breathing frequency during the hyperoxia test measured by ApneaLink Air™ (ResMed)
Continuously from baseline to 10 minutes breathing 10L/min oxygen
Breathing frequency during endurance shuttle walk test
Временное ограничение: Continuously during ESWT, up to 20 minutes
Breathing frequency during the ESWT measured by ApneaLink Air™ (ResMed)
Continuously during ESWT, up to 20 minutes
Heart rate during endurance shuttle walk test
Временное ограничение: Continuously during ESWT, up to 20 minutes
Heart rate measured by continuous transcutaneous recordung via Sentec-Digital Monitor® (Sentec, Therwil, Switzerland)
Continuously during ESWT, up to 20 minutes
Heart rate during hyperoxia test
Временное ограничение: Continuously from baseline to 10 minutes breathing 10L/min oxygen
Heart rate measured by continuous transcutaneous recordung via Sentec-Digital Monitor® (Sentec, Therwil, Switzerland)
Continuously from baseline to 10 minutes breathing 10L/min oxygen
Change of capillary partial pressure of O2 (pO2) during endurance shuttle walk test
Временное ограничение: Change from baseline to the end of the ESWT, up to 20 minutes
pO2 measured by capillary blood gases taken before and after the ESWT
Change from baseline to the end of the ESWT, up to 20 minutes
Change of inspiratory capacity during endurance shuttle walk test
Временное ограничение: Change from baseline to the end of the ESWT, up to 20 minutes
IC measured by SpiroSense (Pari) before and after the ESWT
Change from baseline to the end of the ESWT, up to 20 minutes

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Действительный)

13 июля 2021 г.

Первичное завершение (Ожидаемый)

1 мая 2022 г.

Завершение исследования (Ожидаемый)

1 мая 2022 г.

Даты регистрации исследования

Первый отправленный

4 мая 2021 г.

Впервые представлено, что соответствует критериям контроля качества

5 июля 2021 г.

Первый опубликованный (Действительный)

9 июля 2021 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

14 июля 2021 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

13 июля 2021 г.

Последняя проверка

1 июля 2021 г.

Дополнительная информация

Термины, связанные с этим исследованием

Дополнительные соответствующие термины MeSH

Другие идентификационные номера исследования

  • CO2-Hyperoxia & Exercise

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

ДА

Совместное использование IPD Поддерживающий тип информации

  • STUDY_PROTOCOL
  • МКФ

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться