- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT07560644
Restoring Sinus Rhythm Using Dual-Shock Technique in Patients With Atrial Fibrillation (DUAL-SHOCK)
Restoring Sinus Rhythm Using DUAL-electrical SHOCK Technique: the DUAL-SHOCK Trial
The goal of this clinical trial is to assess the efficacy and acute safety of the dual electrical cardioversion (ECV) technique compared with the conventional ECV in patients with persistent atrial fibrillation. The main question it aims to answer are:
- Is dual ECV more effective than conventional ECV to achieve sinus rhythm restoration?
- Is dual ECV safe compared with conventional ECV?
- Which are the main factors associated with cardioversion success?
Researchers will compare a dual ECV technique with 400J with dual ECV with 200J and conventional ECV.
Participants will be randomized to one ECV configuration. The primary efficacy endpoint will be considered the percentage of patients with successful cardioversion with the first shock. The coprimary safety endpoint will be the occurrence of adverse events during ECV.
Обзор исследования
Статус
Тип исследования
Регистрация (Оцененный)
Фаза
- Фаза 2
- Фаза 3
Контакты и местонахождение
Контакты исследования
- Имя: Martín Negreira-Caamaño, MD, PhD
- Номер телефона: +34 916839360
- Электронная почта: martin.negcam@gmail.com
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
- Взрослый
- Пожилой взрослый
Принимает здоровых добровольцев
Описание
Inclusion Criteria:
- Diagnosis of persistent AF.
- Effective anticoagulation for at least 3 weeks prior to the procedure or exclusion of intra-atrial thrombus by transesophageal echocardiography within the last 24 hours.
- Informed consent obtained.
Exclusion Criteria:
- Long-standing persistent atrial fibrillation (more than 1 year of uninterrupted AF rhythm).
- Emergency indication (hemodynamic instability).
- Cardiac defibrillation following catheter ablation procedures. Cardiac defibrillation performed during the same procedure will be permitted if it is carried out prior to ablation.
- Pregnancy.
- Age <18 years or legal incapacity.
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Уход
- Распределение: Рандомизированный
- Интервенционная модель: Последовательное назначение
- Маскировка: Двойной
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Активный компаратор: Conventional Electrical Cardioversion
Conventional ECV with single pad configurataion in antero-lateral or antero-posterior location.
Energy deliver: 200J
|
Defibrillation pads will be placed in the anteroposterior or anterolateral position. An initial biphasic shock of 200 J will be delivered. If sinus rhythm is not restored, a second dual shock of 400 J (crossover) will be administered. The procedures will be performed in the designated area for such procedures at each center, under deep sedation in accordance with each center's standard protocols. The choice of medication used for sedation will be at the investigator's discretion. All shocks will be delivered using biphasic energy and ECG-synchronized. |
|
Экспериментальный: Dual-Shock 400J
ECV with dual shock technique.
Double pad configuration with electrodes both in antero-lateral and antero-posterior location.
Total energy deliver: 400J.
|
Two pairs of defibrillation pads connected to two different defibrillators will be used. One pair of pads will be placed in the anterolateral position and the second pair in the anteroposterior position. Both defibrillators will be programmed to deliver a biphasic shock of 100 J each (200 J group) or 200 J each (400 J group) simultaneously. The maximum number of CVE attempts per patient will be 3. The procedures will be performed in the designated area for such procedures at each center, under deep sedation in accordance with each center's standard protocols. The choice of medication used for sedation will be at the investigator's discretion. All shocks will be delivered using biphasic energy and synchronized with the QRS complex. |
|
Экспериментальный: Dual-Shock 200J
ECV with dual shock technique.
Double pad configuration with electrodes both in antero-lateral and antero-posterior location.
Total energy deliver: 200J.
|
Two pairs of defibrillation pads connected to two different defibrillators will be used. One pair of pads will be placed in the anterolateral position and the second pair in the anteroposterior position. Both defibrillators will be programmed to deliver a biphasic shock of 100 J each (200 J group) or 200 J each (400 J group) simultaneously. The maximum number of CVE attempts per patient will be 3. The procedures will be performed in the designated area for such procedures at each center, under deep sedation in accordance with each center's standard protocols. The choice of medication used for sedation will be at the investigator's discretion. All shocks will be delivered using biphasic energy and synchronized with the QRS complex. |
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Primary Efficacy Outcome - Patients achieving sinus rhythm with the first shock
Временное ограничение: First minute after first shock delivery
|
Percentage of patients achieving sinus rhythm with the first shock deliver.
Three consecutive beats in sinus rhythm are neccesary to consider sinus rhythm achieved.
|
First minute after first shock delivery
|
|
Primary Safety Outcome - Adverse events during the procedure
Временное ограничение: Before patient are discharged
|
Ocurrence of any complication during the ECV.
Arrhythmic recurrences of atrial fibrillation will not be considered as complications.
|
Before patient are discharged
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Overall Procedural Sucess
Временное ограничение: The end of the procedure
|
Percentage of patients achieving stable sinus rhythm after any number of shocks
|
The end of the procedure
|
|
Overall Intervention-Specific Success
Временное ограничение: First minute after shock delivery
|
Number of successful shocks / Overall delivered shock within the same pad configuration.
|
First minute after shock delivery
|
|
Total Energy Delivered
Временное ограничение: End of the procedure
|
Total energy administered (J) before the procedure is completed
|
End of the procedure
|
|
Sub-acute procedural success
Временное ограничение: At 30 (25-35) days after the procedure
|
Percentage of patients in sinus rhythm at 30 days after the ECV
|
At 30 (25-35) days after the procedure
|
Соавторы и исследователи
Спонсор
Даты записи исследования
Изучение основных дат
Начало исследования (Оцененный)
Первичное завершение (Оцененный)
Завершение исследования (Оцененный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- 25-129
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Описание плана IPD
Совместное использование IPD Поддерживающий тип информации
- STUDY_PROTOCOL
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .