- ICH GCP
- Amerikanska kliniska prövningsregistret
- Klinisk prövning NCT01016925
Bacterial Colonization After Tunneling in Femoral Perineural Catheters (Tunnelized KT)
Background: Bacterial colonization of peripheral nerve catheters is frequent, although infection is relatively rare. With central venous catheters, the tunneling of catheter into the subcutaneous tissue significantly decreases catheter colonization and catheter-related sepsis.
Purpose: The aim of this study is to evaluate the incidence of bacterial colonization in adult patients with femoral tunnelized perineural nerve catheters.
Methods: A total of 338 patients with femoral catheter will be included in the study. The patients will be randomized to be included in the control group (without tunnelling) or in the group with catheter tunneled 2-3 cm subcutaneously. After removal, catheter will be analyzed for colonization (primary outcome). Quantitative culture will be used as described by Brun-Buisson for intravascular catheters. The site of insertion will be monitored daily for any signs of infection (secondary outcome).
Perspective: To show the incidence of femoral perineural catheter colonization is low with subcutaneous tunneling
Studieöversikt
Status
Betingelser
Intervention / Behandling
Studietyp
Inskrivning (Faktisk)
Fas
- Inte tillämpbar
Kontakter och platser
Studieorter
-
-
-
Rouen, Frankrike, 76031
- Rouen University Hospital
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
Tar emot friska volontärer
Beskrivning
Inclusion Criteria:
- Patients scheduled to undergo scheduled orthopaedic surgery performed with a femoral perineural catheter
Exclusion Criteria:
- Age under 18 years
- Local nerve pathology
- Refusal to regional anaesthesia
- Major psychological disorder
- Major cardiac conduction disease
- Infection at the puncture site
Studieplan
Hur är studien utformad?
Designdetaljer
- Primärt syfte: Förebyggande
- Tilldelning: Randomiserad
- Interventionsmodell: Parallellt uppdrag
- Maskning: Enda
Vapen och interventioner
Deltagargrupp / Arm |
Intervention / Behandling |
|---|---|
|
Inget ingripande: Kontrollera
|
|
|
Experimentell: femoral tunnelized perineural catheter
|
the catheter will be tunneled 2-3 cm subcutaneously.
|
Vad mäter studien?
Primära resultatmått
Resultatmått |
Tidsram |
|---|---|
|
incidence of femoral perineural catheter colonization
Tidsram: between 24 hours and 72 hours
|
between 24 hours and 72 hours
|
Samarbetspartners och utredare
Sponsor
Publikationer och användbara länkar
Studieavstämningsdatum
Studera stora datum
Studiestart
Primärt slutförande (Faktisk)
Avslutad studie (Faktisk)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Beräknad)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- 2008/065/HP
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .