Left Ventricular Torsional Hysteresis: A Global Parameter for Diastolic Function
Diastolic dysfunction refers to abnormal mechanical properties of the myocardium and includes abnormal LV diastolic distensibility, impaired filling and slow or delayed relaxation- regardless of whether the ejection fraction is normal or depressed and whether the patient is asymptomatic or symptomatic. Epidemiologic studies have demonstrated high prevalence of diastolic heart failure (DHF). The quality of life of these patients is impaired and the clinical outcomes are similar to those with heart failure with systolic dysfunction. Therefore diastolic dysfunction has significant adverse economic impact that is expected to grow further with time. Clinical characteristics alone may not be sufficient to diagnose diastolic dysfunction. A number of invasive and non-invasive parameters have been proposed to diagnose diastolic dysfunction. Most of the presently used non-invasive parameters have a number of limitations. High fidelity measurement of the left ventricular pressures is needed to accurately diagnose diastolic dysfunction. Obtaining it in routine clinical practice is impractical.
In this protocol the investigators have proposed a novel non-invasive parameter called 'Torsional Hysteresis' as a measure of diastolic function. This will be measured using non-invasive cardiac MRI technique. During left ventricular contraction and relaxation, myocardium deforms. During cardiac cycle the myocardium goes back to baseline state prior to beginning of each contraction. However the rate with which it returns to the baseline state is variable. Torsion indicates relative wringing motion of the ventricle around a left ventricular axis and is a global parameter of left ventricular deformation. The parameters have defined a new parameter called torsional hysteresis based on non invasive cardiac MRI assessment. The parameters have hypothesized that for diastolic dysfunction, the torsional hysteresis area is increased as compared to no diastolic dysfunction group.
Studieöversikt
Status
Studietyp
Inskrivning (Faktisk)
Kontakter och platser
Studieorter
-
-
Alabama
-
Birmingham, Alabama, Förenta staterna, 35243
- VA Medical Center
-
Birmingham, Alabama, Förenta staterna, 35294
- UAB Hospital
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
Tar emot friska volontärer
Kön som är behöriga för studier
Testmetod
Studera befolkning
Beskrivning
Inclusion Criteria:
Major inclusion criteria: Normal screening LV ejection fraction.
Exclusion Criteria:
- Atrial fibrillation or other significant cardiac arrhythmia on ECG
- Presence of pacemaker or defibrillator
- Angioplasty or primary coronary intervention PCI/PTCA during index cardiac catheterization.
- Patient is unable to undergo cardiac MRI due to contraindication to MRI (MRI incompatible metal prosthesis or implants or significant claustrophobia).
- Patient taking phosphodiesterase 5 inhibitor (eg. sildenafil) will be excluded due to potential interaction with nitroglycerin.
Studieplan
Hur är studien utformad?
Designdetaljer
- Observationsmodeller: Endast fall
- Tidsperspektiv: Blivande
Kohorter och interventioner
Grupp / Kohort |
|---|
|
Diastolic Function
Patients scheduled for cardiac catheterization.
|
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
To show that torsional hysteresis relates to invasive hemodynamic measure of diastolic function
Tidsram: one time at enrollment
|
To show that torsional hysteresis relates to invasive hemodynamic measure of diastolic function: a) Exponential fall of pressure during isovolumic relaxation phase by the time constant of relaxation, tau and b) LV end diastolic pressure-volume relationship (EDPVR).
|
one time at enrollment
|
Sekundära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
To demonstrate that torsional hysteresis is a relatively load independent measure of global diastolic function
Tidsram: one time at enrollment
|
To demonstrate that torsional hysteresis is a relatively load independent measure of global diastolic function by evaluating effects of nitroglycerin (NTG) on torsional hysteresis and correlating it to invasive hemodynamic measure of diastolic function including a) tau and b) EDPVR.
|
one time at enrollment
|
|
To evaluate the sensitivity and specificity of torsional hysteresis in diagnosing diastolic dysfunction
Tidsram: one time at enrollment
|
To evaluate the sensitivity and specificity of torsional hysteresis in diagnosing diastolic dysfunction (as defined by invasive hemodynamic parameters: tau, EDPVR) and compare it to echocardiographic tissue Doppler assessment in patients undergoing cardiac catheterization for suspected diastolic dysfunction
|
one time at enrollment
|
Samarbetspartners och utredare
Samarbetspartners
Studieavstämningsdatum
Studera stora datum
Studiestart
Primärt slutförande (Faktisk)
Avslutad studie (Faktisk)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Uppskatta)
Uppdateringar av studier
Senaste uppdatering publicerad (Uppskatta)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- F101215002
- 5R01HL104018 (U.S.S. NIH-anslag/kontrakt)
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .