Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Minimal- Versus High-Flow Sevoflurane and Emergence Agitation in Pediatric Surgery

3 juni 2026 uppdaterad av: Hülya Kaşıkara, Ankara City Hospital Bilkent

Comparison of the Effects of Minimal-Flow and High-Flow Sevoflurane on Emergence Agitation in Opioid-Free Pediatric Surgeries During General Anesthesia Maintenance

This study aims to evaluate the effects of minimal-flow sevoflurane compared with high-flow sevoflurane during maintenance of general anesthesia on postoperative emergence agitation in opioid-free pediatric infraumbilical surgeries. Patients will be randomly assigned to receive either opioid-free minimal-flow anesthesia combined with caudal block or opioid-free high-flow anesthesia combined with caudal block.

The primary outcome is emergence agitation assessed using the Pediatric Anesthesia Emergence Delirium (PAED) scale and the Watcha scale. Secondary outcomes include the incidence of postoperative nausea and vomiting and recovery characteristics. In addition, all patients will be followed up via telephone at 3 months postoperatively to assess the presence of persistent chronic or neuropathic pain at the surgical site.

The findings of this study may contribute to optimizing anesthesia strategies and improving postoperative outcomes in pediatric patients.

Studieöversikt

Status

Aktiv, inte rekryterande

Intervention / Behandling

Detaljerad beskrivning

Emergence agitation (EA) is a common and clinically significant complication in pediatric patients following general anesthesia, particularly after the use of volatile anesthetic agents such as sevoflurane. The etiology of EA is multifactorial and may be associated with rapid emergence, postoperative pain, preoperative anxiety, and the use of opioids. Strategies aimed at reducing opioid consumption and optimizing anesthetic techniques may help improve postoperative recovery profiles in children.

Opioid-free anesthesia (OFA) has gained increasing attention as a multimodal approach that minimizes or eliminates intraoperative opioid use while maintaining adequate analgesia and hemodynamic stability. In addition, low-flow anesthesia techniques may contribute to improved respiratory conditions, better humidification, and more stable anesthetic depth, which could potentially influence emergence characteristics. However, the combined effect of opioid-free and low-flow anesthesia on emergence agitation in pediatric populations has not been sufficiently investigated.

In this prospective, randomized, single-blind study, pediatric patients undergoing infraumbilical surgery will be allocated to receive either opioid-free minimal-flow anesthesia combined with caudal epidural block or conventional anesthesia management. Emergence agitation will be assessed using the Pediatric Anesthesia Emergence Delirium (PAED) scale as the primary outcome, and the Watcha scale as a secondary assessment tool. Additional outcomes include postoperative pain scores, incidence of postoperative nausea and vomiting (PONV), and recovery parameters. This study aims to provide evidence on whether opioid-free minimal-flow anesthesia can improve postoperative behavioral outcomes and enhance recovery quality in pediatric patients.

Studietyp

Interventionell

Inskrivning (Beräknad)

80

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

  • Barn

Tar emot friska volontärer

Ja

Beskrivning

Inclusion Criteria:

  • Pediatric patients aged 2-10 years
  • ASA physical status I-II
  • Scheduled for elective infraumbilical surgery
  • Planned to receive general anesthesia with caudal block
  • Written informed consent obtained from parents or legal guardians

Exclusion Criteria:

  • - Refusal of parental consent
  • Known allergy to study drugs
  • Neurological or developmental disorders
  • Psychiatric disorders or use of psychoactive medications
  • Chronic pain or regular analgesic use
  • Contraindication to caudal block (infection at site, coagulopathy, anatomical abnormality)
  • Significant cardiovascular, respiratory, hepatic, or renal disease
  • Emergency surgery
  • Signs of failed caudal epidural block, defined as a greater than 20% increase in heart rate or blood pressure in response to surgical stimulation, an increase in bispectral index (BIS) values, or the requirement for additional intravenous anesthetic agents.

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Förebyggande
  • Tilldelning: Randomiserad
  • Interventionsmodell: Parallellt uppdrag
  • Maskning: Enda

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Experimentell: opioid-free minimal-flow anesthesia
In this arm, pediatric patients undergoing infraumbilical surgery under opioid-free general anesthesia receive a caudal epidural block after tracheal intubation. Anesthesia is then maintained with minimal-flow sevoflurane.
In all patients, a caudal epidural block is performed after induction of general anesthesia and tracheal intubation, prior to the surgical procedure, to provide perioperative analgesia.
Experimentell: Opioid-Free High-Flow anesthesia
Patients receive opioid-free high-flow sevoflurane anesthesia during maintenance of general anesthesia combined with caudal block.
In all patients, a caudal epidural block is performed after induction of general anesthesia and tracheal intubation, prior to the surgical procedure, to provide perioperative analgesia.

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Emergence agitation assessed by Pediatric Anesthesia Emergence Delirium scale
Tidsram: First 30 minutes in PACU
Pediatric Anesthesia Emergence Delirium (PAED) Scale score ranging from 0 to 20 points. Higher scores indicate more severe emergence delirium. Emergence delirium will be defined as a PAED score ≥10.
First 30 minutes in PACU

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Emergence agitation assessed by Watcha scale
Tidsram: First 30 minutes in the post-anesthesia care unit (PACU)
Emergence agitation will be assessed using the Watcha scale (1-4 points), with higher scores indicating more severe agitation. Patients with a Watcha score ≥3 will be classified as having emergence agitation.
First 30 minutes in the post-anesthesia care unit (PACU)

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Publikationer och användbara länkar

Den som ansvarar för att lägga in information om studien tillhandahåller frivilligt dessa publikationer. Dessa kan handla om allt som har med studien att göra.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Faktisk)

22 april 2026

Primärt slutförande (Beräknad)

22 juni 2026

Avslutad studie (Beräknad)

30 juni 2026

Studieregistreringsdatum

Först inskickad

21 april 2026

Först inskickad som uppfyllde QC-kriterierna

3 juni 2026

Första postat (Faktisk)

9 juni 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

9 juni 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

3 juni 2026

Senast verifierad

1 juni 2026

Mer information

Termer relaterade till denna studie

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

NEJ

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera