此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Limitations of Using a Sheimpflug Image-Based Device for Measuring Anterior Chamber Depth in Pseudophakic Eyes

2008年7月8日 更新者:Far Eastern Memorial Hospital

To Assess the Degree of Agreement of Anterior Chamber Depth Measurements by 2 Optical Devices (Pentacam and IOLMaster) and Compare Them With Contact Ultrasound A-Scan in Phakic and Pseudophakic Eyes.

There have been numerous studies comparing various ACD measurements in phakic eyes,while researches comparing ACD in pseudophakic eyes are less extensive. With the recent popularity of presbyopia correction, measuring the ACD will facilitate differentiating pseudophakic accommodation from pseudoaccommodation. It is thus mandatory to verify the accuracy of ACD measurement of these devices since the innovation of various IOLs in the recent decade makes this task more complicated. In this study, we will assess the limitations of using Pentacam for ACD measurement in pseudophakic eyes and compare Pentacam measurement with IOLMaster and A-scan measurements.

研究概览

地位

完全的

条件

详细说明

In this prospective study, ACD was measured in 90 phakic and 94 pseudophakic eyes by Pentacam, IOLMaster and A-scan. Correlations and differences between the three measurements were investigated. The accuracy in detecting the anterior lens surface in pseudophakic eyes was also assessed.Differences in ACD-Pen, ACD-IOLM, and ACD-A were analyzed using one-way analysis of variance (ANOVA). When an overall significance of P< 0.05 was obtained, pair-wise comparisons were made using Tukey's multiple comparison t tests. The association between ACD-Pen, ACD-IOLM, and ACD-A was assessed using Pearson's correlation test. The distribution of erroneous ACD-Pen measurement for the three IOLs was analyzed with the chi-square test. In all analyses, P <0.05 was considered statistically significant.

研究类型

观察性的

注册 (实际的)

184

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

40年 至 80年 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

取样方法

概率样本

研究人群

Ninety phakic eyes were randomly selected for study from the outpatient clinic. Ninety-four pseudophakic eyes that had a standard clear cornea phacoemulsification with one of three acrylic IOLs (MA60BM, SA60AT, SN60AT) implanted into the capsular bag by the same surgeon were also studied.

描述

Inclusion Criteria:

  • Phakic group: randomized
  • Pseudophakic eyes : the cases accepted cataract surgery

Exclusion Criteria:

  • Previous ocular trauma or intraocular surgery other than cataract surgery;
  • Contact lens use in the past two months;
  • Use of medication that might affect the pupil; corneal disease or ocular infection;
  • History of ocular disease, such as

    • Dry eye syndrome
    • Uveitis
    • Glaucoma
    • Ocular tumor
  • Cases with any surgical complications were also excluded.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
phakic eyes
the cases did not accept any intraocular surgery
pseudophakic eyes
tht cases did not accept any intraocular surgery expect for cataract surgery

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Shu-Wen Chang、Far Eastern Memorial Hospital

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2008年1月1日

初级完成 (实际的)

2008年2月1日

研究完成 (实际的)

2008年2月1日

研究注册日期

首次提交

2008年7月7日

首先提交符合 QC 标准的

2008年7月8日

首次发布 (估计)

2008年7月9日

研究记录更新

最后更新发布 (估计)

2008年7月9日

上次提交的符合 QC 标准的更新

2008年7月8日

最后验证

2008年7月1日

更多信息

与本研究相关的术语

其他相关的 MeSH 术语

其他研究编号

  • FEMH97007

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.