Limitations of Using a Sheimpflug Image-Based Device for Measuring Anterior Chamber Depth in Pseudophakic Eyes
2008年7月8日 更新者:Far Eastern Memorial Hospital
To Assess the Degree of Agreement of Anterior Chamber Depth Measurements by 2 Optical Devices (Pentacam and IOLMaster) and Compare Them With Contact Ultrasound A-Scan in Phakic and Pseudophakic Eyes.
There have been numerous studies comparing various ACD measurements in phakic eyes,while researches comparing ACD in pseudophakic eyes are less extensive.
With the recent popularity of presbyopia correction, measuring the ACD will facilitate differentiating pseudophakic accommodation from pseudoaccommodation.
It is thus mandatory to verify the accuracy of ACD measurement of these devices since the innovation of various IOLs in the recent decade makes this task more complicated.
In this study, we will assess the limitations of using Pentacam for ACD measurement in pseudophakic eyes and compare Pentacam measurement with IOLMaster and A-scan measurements.
調査の概要
状態
完了
条件
詳細な説明
In this prospective study, ACD was measured in 90 phakic and 94 pseudophakic eyes by Pentacam, IOLMaster and A-scan.
Correlations and differences between the three measurements were investigated.
The accuracy in detecting the anterior lens surface in pseudophakic eyes was also assessed.Differences in ACD-Pen, ACD-IOLM, and ACD-A were analyzed using one-way analysis of variance (ANOVA).
When an overall significance of P< 0.05 was obtained, pair-wise comparisons were made using Tukey's multiple comparison t tests.
The association between ACD-Pen, ACD-IOLM, and ACD-A was assessed using Pearson's correlation test.
The distribution of erroneous ACD-Pen measurement for the three IOLs was analyzed with the chi-square test.
In all analyses, P <0.05 was considered statistically significant.
研究の種類
観察的
入学 (実際)
184
参加基準
研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。
適格基準
就学可能な年齢
40年~80年 (大人、高齢者)
健康ボランティアの受け入れ
いいえ
受講資格のある性別
全て
サンプリング方法
確率サンプル
調査対象母集団
Ninety phakic eyes were randomly selected for study from the outpatient clinic.
Ninety-four pseudophakic eyes that had a standard clear cornea phacoemulsification with one of three acrylic IOLs (MA60BM, SA60AT, SN60AT) implanted into the capsular bag by the same surgeon were also studied.
説明
Inclusion Criteria:
- Phakic group: randomized
- Pseudophakic eyes : the cases accepted cataract surgery
Exclusion Criteria:
- Previous ocular trauma or intraocular surgery other than cataract surgery;
- Contact lens use in the past two months;
- Use of medication that might affect the pupil; corneal disease or ocular infection;
History of ocular disease, such as
- Dry eye syndrome
- Uveitis
- Glaucoma
- Ocular tumor
- Cases with any surgical complications were also excluded.
研究計画
このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。
研究はどのように設計されていますか?
デザインの詳細
コホートと介入
グループ/コホート |
---|
phakic eyes
the cases did not accept any intraocular surgery
|
pseudophakic eyes
tht cases did not accept any intraocular surgery expect for cataract surgery
|
協力者と研究者
ここでは、この調査に関係する人々や組織を見つけることができます。
捜査官
- 主任研究者:Shu-Wen Chang、Far Eastern Memorial Hospital
研究記録日
これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。
主要日程の研究
研究開始
2008年1月1日
一次修了 (実際)
2008年2月1日
研究の完了 (実際)
2008年2月1日
試験登録日
最初に提出
2008年7月7日
QC基準を満たした最初の提出物
2008年7月8日
最初の投稿 (見積もり)
2008年7月9日
学習記録の更新
投稿された最後の更新 (見積もり)
2008年7月9日
QC基準を満たした最後の更新が送信されました
2008年7月8日
最終確認日
2008年7月1日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。