The 4-SITE Field Following Study (4-SITE FF) (4-SITE FF)
RELIANCE QUADRIPOLAR DEFIBRILLATION LEADS (4-SITE)FIELD FOLLOWING The 4-SITE Field Following Study (4-SITE FF)
The purpose of this study is to evaluate and document appropriate clinical performance of the new 4-SITE Header / Lead interface in the TELIGEN 100 HE 4-SITE (VR and DR) implantable cardioverter defibrillator (ICD) PGs (Models F103; F111), the COGNIS 100 HE 4-SITE cardiac resynchronization therapy ICD (CRT-D) PG (Model P108) when connected to any of the RELIANCE Quadripolar (4-SITE) defibrillation leads.
Appropriate clinical performance of system components of the 4-SITE systems other than the new 4-SITE header / lead interface has been evaluated and documented already in the previously conducted COGNIS and TELIGEN 100 HE FIELD FOLLOWING STUDY, The COGENT-4 Field Following Study.
Data collected may be used to support international regulatory submissions including the FDA and the Japanese Ministry of Health, Labour and Welfare.
研究概览
地位
详细说明
The following devices will be used (all are CE-marked):
TELIGEN 100 HE 4-SITE (Single and Dual Chamber ICD)
- Model Number: F103 (Quadripolar, VR);
- Model Number: F111 (Quadripolar, IS-1, DR)
COGNIS 100 HE 4-SITE (CRT-D)
o Model Number: P108 (Quadripolar, IS-1, IS-1)
- RELIANCE 4-SITE leads (12 different model numbers in total as shown in the table below)
研究类型
注册 (实际的)
联系人和位置
学习地点
-
-
Nordrhein-Westfalen
-
Bad Oeynhausen、Nordrhein-Westfalen、德国、D - 32545
- Bad Oeynhausen Herz- und Diabeteszentrum Nordrhein-Westfalen
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
取样方法
研究人群
描述
Inclusion Criteria:
Study Specific:
- ICD / CRT-D Indication according to normal clinical practice
- Patients receiving:
- a single or dual chamber 4-SITE compatible ICD
- or a 4-SITE compatible CRT-D
- one of the RELIANCE 4-SITE defibrillation leads
- Patients currently implanted with a pacemaker
- upgraded to a 4-SITE compatible ICD or CRT-D (4-SITE header)
- one of the RELIANCE 4-SITE defibrillation leads
General:
- Willing and capable of providing informed consent for
- undergoing a 4-SITE system implant,
- participating in all testing associated with this clinical investigation at an approved clinical investigational centre and at the intervals defined by this protocol
- Geographically stable patients who are available for follow-up at a study centre
- Age 18 or above, or of legal age to give informed consent specific to national law
Exclusion Criteria:
Study Specific:
- ICD and CRT-D Patients scheduled for a device replacement
- CRM Patients who have or who would need an lead adaptor
- All patients who have an active or non-active defibrillation lead other than 4-SITE
General:
- Not willing and not capable of providing informed consent, undergoing a device implant, participating in all testing associated with this clinical investigation (including VT/VF shock conversion) at an approved clinical investigational centre and at the intervals defined by this protocol
- Patients who were in NYHA Class IV during the last 3 month
- Patients with pre-existing diseases, which may confound study results
- Patients currently requiring dialysis,
- Cancer patients
- Patients with drug and/or alcohol abuse history
- Life expectancy < 12 months (or expected heart transplant within 12 months)
- Patients on a Heart Transplant List
- Women who are pregnant or plan to become pregnant. Method of assessment per physician discretion.
- Enrolled in any other concurrent study
学习计划
研究是如何设计的?
设计细节
- 时间观点:预期
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Appropriate Detection of induced VT
大体时间:At Implant or during VT/VF testing up to one month after implant
|
Induced mean VT/VF detection time < 4.5 seconds
|
At Implant or during VT/VF testing up to one month after implant
|
|
Appropriate induced VT/VF Shock Conversion
大体时间:At Implant or during testing within one month after implant
|
Successful VT/VF conversions (with 41 J, no external shock) will be 93% or higher
|
At Implant or during testing within one month after implant
|
|
Appropriate pacing thresholds at follow-up with the 4-SITE defibrillation leads
大体时间:entire duration of the study
|
Mean pacing threshold post implant ≤ 1.5V
|
entire duration of the study
|
|
Appropriate Lead Impedances as a measure of lead integrity over 12 month time
大体时间:entire study duration
|
|
entire study duration
|
|
Appropriate sensing and absence of artefacts
大体时间:entire duration of study
|
Appropriate sensing and absence of artefacts during standardized pocket manipulations and standardized provocative maneuvers during FU
|
entire duration of study
|
合作者和调查者
研究记录日期
研究主要日期
学习开始
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (估计)
研究记录更新
最后更新发布 (估计)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- 4-SITE FF 0209
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.