RELIANCE QUADRIPOLAR DEFIBRILLATION LEADS (4-SITE)FIELD FOLLOWING The 4-SITE Field Following Study (4-SITE FF)

The purpose of this study is to evaluate and document appropriate clinical performance of the new 4-SITE Header / Lead interface in the TELIGEN 100 HE 4-SITE (VR and DR) implantable cardioverter defibrillator (ICD) PGs (Models F103; F111), the COGNIS 100 HE 4-SITE cardiac resynchronization therapy ICD (CRT-D) PG (Model P108) when connected to any of the RELIANCE Quadripolar (4-SITE) defibrillation leads.

Appropriate clinical performance of system components of the 4-SITE systems other than the new 4-SITE header / lead interface has been evaluated and documented already in the previously conducted COGNIS and TELIGEN 100 HE FIELD FOLLOWING STUDY, The COGENT-4 Field Following Study.

Data collected may be used to support international regulatory submissions including the FDA and the Japanese Ministry of Health, Labour and Welfare.

Studienübersicht

Status

Abgeschlossen

Detaillierte Beschreibung

The following devices will be used (all are CE-marked):

  • TELIGEN 100 HE 4-SITE (Single and Dual Chamber ICD)

    • Model Number: F103 (Quadripolar, VR);
    • Model Number: F111 (Quadripolar, IS-1, DR)
  • COGNIS 100 HE 4-SITE (CRT-D)

    o Model Number: P108 (Quadripolar, IS-1, IS-1)

  • RELIANCE 4-SITE leads (12 different model numbers in total as shown in the table below)

Studientyp

Beobachtungs

Einschreibung (Tatsächlich)

430

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

    • Nordrhein-Westfalen
      • Bad Oeynhausen, Nordrhein-Westfalen, Deutschland, D - 32545
        • Bad Oeynhausen Herz- und Diabeteszentrum Nordrhein-Westfalen

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre und älter (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Probenahmeverfahren

Wahrscheinlichkeitsstichprobe

Studienpopulation

Study Population: Patients should be selected from the investigator's general population indicated for an ICD or CRT-D Implantation. The investigator has the responsibility of screening all potential patients and selecting those who meet study eligibility criteria.

Beschreibung

Inclusion Criteria:

Study Specific:

  • ICD / CRT-D Indication according to normal clinical practice
  • Patients receiving:
  • a single or dual chamber 4-SITE compatible ICD
  • or a 4-SITE compatible CRT-D
  • one of the RELIANCE 4-SITE defibrillation leads
  • Patients currently implanted with a pacemaker
  • upgraded to a 4-SITE compatible ICD or CRT-D (4-SITE header)
  • one of the RELIANCE 4-SITE defibrillation leads

General:

  • Willing and capable of providing informed consent for
  • undergoing a 4-SITE system implant,
  • participating in all testing associated with this clinical investigation at an approved clinical investigational centre and at the intervals defined by this protocol
  • Geographically stable patients who are available for follow-up at a study centre
  • Age 18 or above, or of legal age to give informed consent specific to national law

Exclusion Criteria:

Study Specific:

  • ICD and CRT-D Patients scheduled for a device replacement
  • CRM Patients who have or who would need an lead adaptor
  • All patients who have an active or non-active defibrillation lead other than 4-SITE

General:

  • Not willing and not capable of providing informed consent, undergoing a device implant, participating in all testing associated with this clinical investigation (including VT/VF shock conversion) at an approved clinical investigational centre and at the intervals defined by this protocol
  • Patients who were in NYHA Class IV during the last 3 month
  • Patients with pre-existing diseases, which may confound study results
  • Patients currently requiring dialysis,
  • Cancer patients
  • Patients with drug and/or alcohol abuse history
  • Life expectancy < 12 months (or expected heart transplant within 12 months)
  • Patients on a Heart Transplant List
  • Women who are pregnant or plan to become pregnant. Method of assessment per physician discretion.
  • Enrolled in any other concurrent study

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Zeitperspektiven: Interessent

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Appropriate Detection of induced VT
Zeitfenster: At Implant or during VT/VF testing up to one month after implant
Induced mean VT/VF detection time < 4.5 seconds
At Implant or during VT/VF testing up to one month after implant
Appropriate induced VT/VF Shock Conversion
Zeitfenster: At Implant or during testing within one month after implant
Successful VT/VF conversions (with 41 J, no external shock) will be 93% or higher
At Implant or during testing within one month after implant
Appropriate pacing thresholds at follow-up with the 4-SITE defibrillation leads
Zeitfenster: entire duration of the study
Mean pacing threshold post implant ≤ 1.5V
entire duration of the study
Appropriate Lead Impedances as a measure of lead integrity over 12 month time
Zeitfenster: entire study duration
  • Shocking lead impedance should be within the range of 20 and 80 OHM
  • Pace /sense lead impedance within 200 and 2000 OHM
entire study duration
Appropriate sensing and absence of artefacts
Zeitfenster: entire duration of study
Appropriate sensing and absence of artefacts during standardized pocket manipulations and standardized provocative maneuvers during FU
entire duration of study

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn

1. Mai 2009

Primärer Abschluss (Tatsächlich)

1. Januar 2011

Studienabschluss (Tatsächlich)

1. Januar 2011

Studienanmeldedaten

Zuerst eingereicht

12. Juni 2009

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

12. Juni 2009

Zuerst gepostet (Schätzen)

15. Juni 2009

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Schätzen)

5. Dezember 2012

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

3. Dezember 2012

Zuletzt verifiziert

1. November 2010

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur ICD and CRT-D Indicated Patients

Abonnieren