- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT00920452
The 4-SITE Field Following Study (4-SITE FF) (4-SITE FF)
RELIANCE QUADRIPOLAR DEFIBRILLATION LEADS (4-SITE)FIELD FOLLOWING The 4-SITE Field Following Study (4-SITE FF)
The purpose of this study is to evaluate and document appropriate clinical performance of the new 4-SITE Header / Lead interface in the TELIGEN 100 HE 4-SITE (VR and DR) implantable cardioverter defibrillator (ICD) PGs (Models F103; F111), the COGNIS 100 HE 4-SITE cardiac resynchronization therapy ICD (CRT-D) PG (Model P108) when connected to any of the RELIANCE Quadripolar (4-SITE) defibrillation leads.
Appropriate clinical performance of system components of the 4-SITE systems other than the new 4-SITE header / lead interface has been evaluated and documented already in the previously conducted COGNIS and TELIGEN 100 HE FIELD FOLLOWING STUDY, The COGENT-4 Field Following Study.
Data collected may be used to support international regulatory submissions including the FDA and the Japanese Ministry of Health, Labour and Welfare.
Descripción general del estudio
Estado
Condiciones
Descripción detallada
The following devices will be used (all are CE-marked):
TELIGEN 100 HE 4-SITE (Single and Dual Chamber ICD)
- Model Number: F103 (Quadripolar, VR);
- Model Number: F111 (Quadripolar, IS-1, DR)
COGNIS 100 HE 4-SITE (CRT-D)
o Model Number: P108 (Quadripolar, IS-1, IS-1)
- RELIANCE 4-SITE leads (12 different model numbers in total as shown in the table below)
Tipo de estudio
Inscripción (Actual)
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Nordrhein-Westfalen
-
Bad Oeynhausen, Nordrhein-Westfalen, Alemania, D - 32545
- Bad Oeynhausen Herz- und Diabeteszentrum Nordrhein-Westfalen
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
Descripción
Inclusion Criteria:
Study Specific:
- ICD / CRT-D Indication according to normal clinical practice
- Patients receiving:
- a single or dual chamber 4-SITE compatible ICD
- or a 4-SITE compatible CRT-D
- one of the RELIANCE 4-SITE defibrillation leads
- Patients currently implanted with a pacemaker
- upgraded to a 4-SITE compatible ICD or CRT-D (4-SITE header)
- one of the RELIANCE 4-SITE defibrillation leads
General:
- Willing and capable of providing informed consent for
- undergoing a 4-SITE system implant,
- participating in all testing associated with this clinical investigation at an approved clinical investigational centre and at the intervals defined by this protocol
- Geographically stable patients who are available for follow-up at a study centre
- Age 18 or above, or of legal age to give informed consent specific to national law
Exclusion Criteria:
Study Specific:
- ICD and CRT-D Patients scheduled for a device replacement
- CRM Patients who have or who would need an lead adaptor
- All patients who have an active or non-active defibrillation lead other than 4-SITE
General:
- Not willing and not capable of providing informed consent, undergoing a device implant, participating in all testing associated with this clinical investigation (including VT/VF shock conversion) at an approved clinical investigational centre and at the intervals defined by this protocol
- Patients who were in NYHA Class IV during the last 3 month
- Patients with pre-existing diseases, which may confound study results
- Patients currently requiring dialysis,
- Cancer patients
- Patients with drug and/or alcohol abuse history
- Life expectancy < 12 months (or expected heart transplant within 12 months)
- Patients on a Heart Transplant List
- Women who are pregnant or plan to become pregnant. Method of assessment per physician discretion.
- Enrolled in any other concurrent study
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Perspectivas temporales: Futuro
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Appropriate Detection of induced VT
Periodo de tiempo: At Implant or during VT/VF testing up to one month after implant
|
Induced mean VT/VF detection time < 4.5 seconds
|
At Implant or during VT/VF testing up to one month after implant
|
|
Appropriate induced VT/VF Shock Conversion
Periodo de tiempo: At Implant or during testing within one month after implant
|
Successful VT/VF conversions (with 41 J, no external shock) will be 93% or higher
|
At Implant or during testing within one month after implant
|
|
Appropriate pacing thresholds at follow-up with the 4-SITE defibrillation leads
Periodo de tiempo: entire duration of the study
|
Mean pacing threshold post implant ≤ 1.5V
|
entire duration of the study
|
|
Appropriate Lead Impedances as a measure of lead integrity over 12 month time
Periodo de tiempo: entire study duration
|
|
entire study duration
|
|
Appropriate sensing and absence of artefacts
Periodo de tiempo: entire duration of study
|
Appropriate sensing and absence of artefacts during standardized pocket manipulations and standardized provocative maneuvers during FU
|
entire duration of study
|
Colaboradores e Investigadores
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
- 4-SITE FF 0209
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .