e- Ab Sensor - Based Real-time Diagnosis of Enterovirus Type 71

2012年12月26日 更新者:National Taiwan University Hospital
To develop a real-time diagnostic technique with e- Ab sensor for Entervirus 71 detection, the investigators conduct a prospective clinical study. In comparison with results from direct sequencing of Entervirus 71, the investigators evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction. The potential factors which may interfere with the results would be investigated. With such technique, the investigators hope to make early diagnosis and give EV71 patients early treatment to reduce the complications and case-fatality rate.

研究概览

详细说明

Entervirus 71 is one of the most important infectious diseases in children and the important concern in public health. Since 1998, EV71 has become an endemic disease in Taiwan and caused hundreds of severe cases and dozens of fatal cases each year due to lack of EV71 vaccine. Family transmission study also showed that it is highly contagious among households as well as in daycares or kindergartens. Therefore, a rapid diagnosis is clinically necessary and can provide clinicians the rapid answers and make early treatment possible to reduce the complications and case-fatality rate. In addition, early diagnosis of the patients will alert parents and public health workers to prevent the contacts earlier and to limit the EV71 spread.

Electrosensing antibody probing system (e- Ab sensor), which was developed for the rapid and sensitive detection of hapten, proteins or viral antigen in medical samples, will be used for analyzing the interaction kinetics between Q.anti-EV71 and its antigen EV71 present in EV71 patients and normal sample. The system incorporates the use of engineered semiconductive antibodies or virus in vertical and lateral chip (eVchip) or lateral flow through (eVsignal) formats. In electrosensing virus probing, semiconductive antibodies are bound as a suitable electrosensing probe which specifically and selectively binds EV71 epitope target molecules in the test serum. In comparison with results from direct sequencing of EV71, the investigators evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction. The potential factors which may interfere with the results would be investigated. e- Ab sensor threshold decisions must maximize its sensitivity. Therefore, the threshold value in the test group is to find the decision could have 90% sensitivity and 90% specificity. With such technique, the investigators hope to make early diagnosis and give EV71 patients early treatment to reduce the complications and case-fatality rate.

研究类型

介入性

注册 (预期的)

72

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Taipei、台湾、10051
        • 招聘中
        • National Taiwan University Hospital
        • 接触:
        • 首席研究员:
          • Luan-Yin Chang, MD/PhD

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 孩子
  • 成人
  • 年长者

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  • A: The patients with confirmed or suspected infection.
  • B: The patients without disease.

Exclusion Criteria:

  • Patients will be excluded if they couldn't sign the consent.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:诊断
  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:双倍的

武器和干预

参与者组/臂
干预/治疗
实验性的:virus detection
Electrosensing antibody probing system (e- Ab sensor), which was developed for the rapid and sensitive detection of hapten, proteins, or viral antigen in medical samples, will be used for analyzing the interaction kinetics between anti-EV71 antibody and its antigen (EV71) present in patients. The system incorporates the use of engineered semiconducive antibodies or virus in vertical and lateral chip (eAbchip) or lateral flow through (eAbsignal) formats. In electrosensing antibody probing, semiconductive antibodies are bound as a suitable electrosensing probe, which specifically and selectively binds targeted molecules (EV71) in the test specimens. From assessment of the electric signature of semiconductive anti-EV71 antibodies, the eABprobe could offer sensitive detection and precise quantification of EV71.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
The performance of e- Ab sensor
大体时间:1 Day
In comparison with results from direct sequencing of EV71, we evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction.
1 Day

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Luan-Yin Chang, MD,PhD、National Taiwan University Hospital

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2010年7月1日

初级完成 (预期的)

2013年7月1日

研究完成 (预期的)

2013年7月1日

研究注册日期

首次提交

2011年7月1日

首先提交符合 QC 标准的

2011年7月5日

首次发布 (估计)

2011年7月6日

研究记录更新

最后更新发布 (估计)

2012年12月27日

上次提交的符合 QC 标准的更新

2012年12月26日

最后验证

2011年11月1日

更多信息

与本研究相关的术语

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅