- ICH GCP
- Amerikanska kliniska prövningsregistret
- Klinisk prövning NCT01388049
e- Ab Sensor - Based Real-time Diagnosis of Enterovirus Type 71
Studieöversikt
Status
Betingelser
Intervention / Behandling
Detaljerad beskrivning
Entervirus 71 is one of the most important infectious diseases in children and the important concern in public health. Since 1998, EV71 has become an endemic disease in Taiwan and caused hundreds of severe cases and dozens of fatal cases each year due to lack of EV71 vaccine. Family transmission study also showed that it is highly contagious among households as well as in daycares or kindergartens. Therefore, a rapid diagnosis is clinically necessary and can provide clinicians the rapid answers and make early treatment possible to reduce the complications and case-fatality rate. In addition, early diagnosis of the patients will alert parents and public health workers to prevent the contacts earlier and to limit the EV71 spread.
Electrosensing antibody probing system (e- Ab sensor), which was developed for the rapid and sensitive detection of hapten, proteins or viral antigen in medical samples, will be used for analyzing the interaction kinetics between Q.anti-EV71 and its antigen EV71 present in EV71 patients and normal sample. The system incorporates the use of engineered semiconductive antibodies or virus in vertical and lateral chip (eVchip) or lateral flow through (eVsignal) formats. In electrosensing virus probing, semiconductive antibodies are bound as a suitable electrosensing probe which specifically and selectively binds EV71 epitope target molecules in the test serum. In comparison with results from direct sequencing of EV71, the investigators evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction. The potential factors which may interfere with the results would be investigated. e- Ab sensor threshold decisions must maximize its sensitivity. Therefore, the threshold value in the test group is to find the decision could have 90% sensitivity and 90% specificity. With such technique, the investigators hope to make early diagnosis and give EV71 patients early treatment to reduce the complications and case-fatality rate.
Studietyp
Inskrivning (Förväntat)
Fas
- Inte tillämpbar
Kontakter och platser
Studieorter
-
-
-
Taipei, Taiwan, 10051
- Rekrytering
- National Taiwan University Hospital
-
Kontakt:
- Luan-Yin Chang, MD,PhD
- Telefonnummer: 71528 886-2-2312-3456
- E-post: lychang@ntu.edu.tw
-
Huvudutredare:
- Luan-Yin Chang, MD/PhD
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
- Barn
- Vuxen
- Äldre vuxen
Tar emot friska volontärer
Kön som är behöriga för studier
Beskrivning
Inclusion Criteria:
- A: The patients with confirmed or suspected infection.
- B: The patients without disease.
Exclusion Criteria:
- Patients will be excluded if they couldn't sign the consent.
Studieplan
Hur är studien utformad?
Designdetaljer
- Primärt syfte: Diagnostisk
- Tilldelning: N/A
- Interventionsmodell: Enskild gruppuppgift
- Maskning: Dubbel
Vapen och interventioner
Deltagargrupp / Arm |
Intervention / Behandling |
|---|---|
|
Experimentell: virus detection
|
Electrosensing antibody probing system (e- Ab sensor), which was developed for the rapid and sensitive detection of hapten, proteins, or viral antigen in medical samples, will be used for analyzing the interaction kinetics between anti-EV71 antibody and its antigen (EV71) present in patients.
The system incorporates the use of engineered semiconducive antibodies or virus in vertical and lateral chip (eAbchip) or lateral flow through (eAbsignal) formats.
In electrosensing antibody probing, semiconductive antibodies are bound as a suitable electrosensing probe, which specifically and selectively binds targeted molecules (EV71) in the test specimens.
From assessment of the electric signature of semiconductive anti-EV71 antibodies, the eABprobe could offer sensitive detection and precise quantification of EV71.
|
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
The performance of e- Ab sensor
Tidsram: 1 Day
|
In comparison with results from direct sequencing of EV71, we evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction.
|
1 Day
|
Samarbetspartners och utredare
Utredare
- Huvudutredare: Luan-Yin Chang, MD,PhD, National Taiwan University Hospital
Studieavstämningsdatum
Studera stora datum
Studiestart
Primärt slutförande (Förväntat)
Avslutad studie (Förväntat)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Uppskatta)
Uppdateringar av studier
Senaste uppdatering publicerad (Uppskatta)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Nyckelord
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- 201007053R
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .