- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT01388049
e- Ab Sensor - Based Real-time Diagnosis of Enterovirus Type 71
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Szczegółowy opis
Entervirus 71 is one of the most important infectious diseases in children and the important concern in public health. Since 1998, EV71 has become an endemic disease in Taiwan and caused hundreds of severe cases and dozens of fatal cases each year due to lack of EV71 vaccine. Family transmission study also showed that it is highly contagious among households as well as in daycares or kindergartens. Therefore, a rapid diagnosis is clinically necessary and can provide clinicians the rapid answers and make early treatment possible to reduce the complications and case-fatality rate. In addition, early diagnosis of the patients will alert parents and public health workers to prevent the contacts earlier and to limit the EV71 spread.
Electrosensing antibody probing system (e- Ab sensor), which was developed for the rapid and sensitive detection of hapten, proteins or viral antigen in medical samples, will be used for analyzing the interaction kinetics between Q.anti-EV71 and its antigen EV71 present in EV71 patients and normal sample. The system incorporates the use of engineered semiconductive antibodies or virus in vertical and lateral chip (eVchip) or lateral flow through (eVsignal) formats. In electrosensing virus probing, semiconductive antibodies are bound as a suitable electrosensing probe which specifically and selectively binds EV71 epitope target molecules in the test serum. In comparison with results from direct sequencing of EV71, the investigators evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction. The potential factors which may interfere with the results would be investigated. e- Ab sensor threshold decisions must maximize its sensitivity. Therefore, the threshold value in the test group is to find the decision could have 90% sensitivity and 90% specificity. With such technique, the investigators hope to make early diagnosis and give EV71 patients early treatment to reduce the complications and case-fatality rate.
Typ studiów
Zapisy (Oczekiwany)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Taipei, Tajwan, 10051
- Rekrutacyjny
- National Taiwan University Hospital
-
Kontakt:
- Luan-Yin Chang, MD,PhD
- Numer telefonu: 71528 886-2-2312-3456
- E-mail: lychang@ntu.edu.tw
-
Główny śledczy:
- Luan-Yin Chang, MD/PhD
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dziecko
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- A: The patients with confirmed or suspected infection.
- B: The patients without disease.
Exclusion Criteria:
- Patients will be excluded if they couldn't sign the consent.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Diagnostyczny
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Podwójnie
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Eksperymentalny: virus detection
|
Electrosensing antibody probing system (e- Ab sensor), which was developed for the rapid and sensitive detection of hapten, proteins, or viral antigen in medical samples, will be used for analyzing the interaction kinetics between anti-EV71 antibody and its antigen (EV71) present in patients.
The system incorporates the use of engineered semiconducive antibodies or virus in vertical and lateral chip (eAbchip) or lateral flow through (eAbsignal) formats.
In electrosensing antibody probing, semiconductive antibodies are bound as a suitable electrosensing probe, which specifically and selectively binds targeted molecules (EV71) in the test specimens.
From assessment of the electric signature of semiconductive anti-EV71 antibodies, the eABprobe could offer sensitive detection and precise quantification of EV71.
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
The performance of e- Ab sensor
Ramy czasowe: 1 Day
|
In comparison with results from direct sequencing of EV71, we evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction.
|
1 Day
|
Współpracownicy i badacze
Śledczy
- Główny śledczy: Luan-Yin Chang, MD,PhD, National Taiwan University Hospital
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Zakończenie podstawowe (Oczekiwany)
Ukończenie studiów (Oczekiwany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- 201007053R
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .