Comparison of Biodegradable Polymer vs Durable-polymer in Diabetic Patients (RUDI 2D)
Long-term Comparison of Biodegradable Polymer Biolimus-eluting Stents and Durable-polymer Everolimus-eluting Stents in Patients With Diabetes Mellitus
Both biodegradable polymer-based biolimus-eluting stents (BP-BES) and durable polymer-based everolimus-eluting stents (DP-EES) have been shown to improve long-term clinical outcomes as compared with early generation DES. BP-BES with DP-EES have been directly compared in 2 randomized trials, showing no differences between the two devices in all-comer patients during long-term follow-up. It is unknown whether these results are consistent in real-world patients with diabetes mellitus during long-term follow-up. To evaluate the safety and efficacy profile of biodegradable polymer-coated biolimus-eluting stents (BP-BES) as compared to durable polymer-coated everolimus-eluting stents (DP-EES) in patients with diabetes mellitus during long-term follow-up.
Consecutive diabetic patients undergoing percutaneous coronary interventions with BP-BES or DP-EES implantation were included in a multicenter registry between January 2007 and May 2012. Long-term clinical outcomes between BP-BES and DP-EES will be compared using propensity score matching. The pre-specified primary endpoint is the occurrence of major cardiac adverse events (MACE) - a composite of all-cause death, myocardial infarction (MI) or target-vessel revascularization (TVR). Secondary endpoints are the individual components of the primary endpoint as well as definite stent thrombosis (ST).
研究概览
研究类型
注册 (实际的)
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
取样方法
研究人群
描述
Inclusion Criteria:
- age > 18 years
- diabetes mellitus
- percutaneous coronary interventions with biolimus eluting stent or everolimus eluting stent implantation
- signed informed consent
Exclusion Criteria:
- planned procedure requiring antiplatelet therapy withdrawal within 12 months from index coronary angioplasty
- patients with contraindication to dual antiplatelet therapy (aspirin plus ticlopidine or clopidogrel)
- known allergy to stent drugs
学习计划
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
biodegradable polymer
|
Consecutive diabetic patients undergoing percutaneous coronary interventions with Biodegradable polymer Biolimus Eluting Stent or durable polymer Everolimus Eluting Stent implantation
|
|
durable-polymer
|
Consecutive diabetic patients undergoing percutaneous coronary interventions with Biodegradable polymer Biolimus Eluting Stent or durable polymer Everolimus Eluting Stent implantation
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
major cardiac adverse events
大体时间:4 years
|
a composite of all-cause death, myocardial infarction (MI) or target-vessel revascularization (TVR)
|
4 years
|
次要结果测量
结果测量 |
大体时间 |
|---|---|
|
rate of definite stent thrombosis in revascularized patients according with ARC definition
大体时间:4 years
|
4 years
|
|
Rate of composite of all-cause death in all participants
大体时间:4 years
|
4 years
|
|
Rate of myocardial infarction according with definition of MI type 1in all participants
大体时间:4 years
|
4 years
|
|
Rate of target-vessel revascularization (TVR) in all participants
大体时间:4 years
|
4 years
|
合作者和调查者
研究记录日期
研究主要日期
学习开始
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (估计)
研究记录更新
最后更新发布 (估计)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.