Comparison of Biodegradable Polymer vs Durable-polymer in Diabetic Patients (RUDI 2D)

29 juli 2016 bijgewerkt door: Gennaro Sardella, University of Roma La Sapienza

Long-term Comparison of Biodegradable Polymer Biolimus-eluting Stents and Durable-polymer Everolimus-eluting Stents in Patients With Diabetes Mellitus

Both biodegradable polymer-based biolimus-eluting stents (BP-BES) and durable polymer-based everolimus-eluting stents (DP-EES) have been shown to improve long-term clinical outcomes as compared with early generation DES. BP-BES with DP-EES have been directly compared in 2 randomized trials, showing no differences between the two devices in all-comer patients during long-term follow-up. It is unknown whether these results are consistent in real-world patients with diabetes mellitus during long-term follow-up. To evaluate the safety and efficacy profile of biodegradable polymer-coated biolimus-eluting stents (BP-BES) as compared to durable polymer-coated everolimus-eluting stents (DP-EES) in patients with diabetes mellitus during long-term follow-up.

Consecutive diabetic patients undergoing percutaneous coronary interventions with BP-BES or DP-EES implantation were included in a multicenter registry between January 2007 and May 2012. Long-term clinical outcomes between BP-BES and DP-EES will be compared using propensity score matching. The pre-specified primary endpoint is the occurrence of major cardiac adverse events (MACE) - a composite of all-cause death, myocardial infarction (MI) or target-vessel revascularization (TVR). Secondary endpoints are the individual components of the primary endpoint as well as definite stent thrombosis (ST).

Studie Overzicht

Studietype

Observationeel

Inschrijving (Werkelijk)

1347

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

18 jaar tot 95 jaar (Volwassen, Oudere volwassene)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Bemonsteringsmethode

Kanssteekproef

Studie Bevolking

Consecutive diabetic patients with coronary artery diseases undergoing percutaneous coronary interventions with BP-BES or DP-EES implantation between January 2007 and May 2012

Beschrijving

Inclusion Criteria:

  • age > 18 years
  • diabetes mellitus
  • percutaneous coronary interventions with biolimus eluting stent or everolimus eluting stent implantation
  • signed informed consent

Exclusion Criteria:

  • planned procedure requiring antiplatelet therapy withdrawal within 12 months from index coronary angioplasty
  • patients with contraindication to dual antiplatelet therapy (aspirin plus ticlopidine or clopidogrel)
  • known allergy to stent drugs

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

Cohorten en interventies

Groep / Cohort
Interventie / Behandeling
biodegradable polymer
Consecutive diabetic patients undergoing percutaneous coronary interventions with Biodegradable polymer Biolimus Eluting Stent or durable polymer Everolimus Eluting Stent implantation
durable-polymer
Consecutive diabetic patients undergoing percutaneous coronary interventions with Biodegradable polymer Biolimus Eluting Stent or durable polymer Everolimus Eluting Stent implantation

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
major cardiac adverse events
Tijdsspanne: 4 years
a composite of all-cause death, myocardial infarction (MI) or target-vessel revascularization (TVR)
4 years

Secundaire uitkomstmaten

Uitkomstmaat
Tijdsspanne
rate of definite stent thrombosis in revascularized patients according with ARC definition
Tijdsspanne: 4 years
4 years
Rate of composite of all-cause death in all participants
Tijdsspanne: 4 years
4 years
Rate of myocardial infarction according with definition of MI type 1in all participants
Tijdsspanne: 4 years
4 years
Rate of target-vessel revascularization (TVR) in all participants
Tijdsspanne: 4 years
4 years

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start

1 januari 2007

Primaire voltooiing (Werkelijk)

1 mei 2012

Studie voltooiing (Werkelijk)

1 januari 2016

Studieregistratiedata

Eerst ingediend

1 februari 2016

Eerst ingediend dat voldeed aan de QC-criteria

29 juli 2016

Eerst geplaatst (Schatting)

3 augustus 2016

Updates van studierecords

Laatste update geplaatst (Schatting)

3 augustus 2016

Laatste update ingediend die voldeed aan QC-criteria

29 juli 2016

Laatst geverifieerd

1 juli 2016

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • RUDI 2D

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .