此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Effectiveness of Nasal Endoscope Sterilization Using a Novel Rig-S™ Device

2020年10月25日 更新者:Azlina Ab Rani、Universiti Kebangsaan Malaysia Medical Centre

Effectiveness of Nasal Endoscope Sterilization Using a Novel Rig-S™ Device: A Randomized Controlled Trial

This study compares the sterility of rigid nasoendoscopies after being sterilized with a conventional autoclave machine and a novel rig-S device that uses standard high level disinfectant

研究概览

详细说明

There is a standard operating procedure in rigid endoscopy cleaning, and it is performed after each clinical examination. The conventional autoclave is no longer used in the setting of an otorhinolaryngology (ORL) clinic as it is cumbersome and takes a lot of time, and also only cleans one endoscope at a time. There is no standardisation or device that has been reported, and cross contamination has been reported previously. The overturn of patients in the ORL clinic is high, and most practitioners chooses high level disinfectant as a method of sterilising the endoscopes. However, there is no proper device to place these disinfectants in, and results in many cases of broken scopes and cross contamination.

This study compares the sterility of the rigid endoscopes after being sterilised by the high level disinfectant that is placed in a novel rig-S device with the gold standard conventional autoclave.

The investigators selected all the rigid endoscopes performed in our ORL clinic and randomised them before subjecting them for a swab test for bacterial and fungal, and also used a test kit to test the presence of Hepatitis B.

研究类型

介入性

注册 (实际的)

500

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Kuala Lumpur
      • Cheras、Kuala Lumpur、马来西亚、56000
        • Universiti Kebangsaan Malaysia

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

是的

有资格学习的性别

全部

描述

Inclusion Criteria:

All rigid endoscopes performed in ORL clinic

Exclusion Criteria:

Flexible endoscopes performed in ORL clinic

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:其他
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:单身的

武器和干预

参与者组/臂
干预/治疗
有源比较器:Conventional Autoclave
The conventional autoclave is the gold standard of sterilising all medical equipments.
A new device created to hold the high level disinfectant and automatically indicate when sterilisation process has been completed
The gold standard device to clean all medical instruments
有源比较器:Novel rig-S
A novel devise used with the high level disinfectant
A new device created to hold the high level disinfectant and automatically indicate when sterilisation process has been completed
The gold standard device to clean all medical instruments

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Microbial and Hepatitis B test
大体时间:3 days
Rigid endoscopes are swabbed and tested using a hep-B kit
3 days

次要结果测量

结果测量
措施说明
大体时间
Acidity level
大体时间:4 hours
Acidity level of the high level disinfectant is tested for every 10 cycles of scope
4 hours

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 研究主任:Salina Husain, MMED、Universiti Kebangsaan Malaysia Medical Centre

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2018年10月1日

初级完成 (实际的)

2020年2月28日

研究完成 (实际的)

2020年2月28日

研究注册日期

首次提交

2020年10月16日

首先提交符合 QC 标准的

2020年10月25日

首次发布 (实际的)

2020年10月27日

研究记录更新

最后更新发布 (实际的)

2020年10月27日

上次提交的符合 QC 标准的更新

2020年10月25日

最后验证

2020年10月1日

更多信息

与本研究相关的术语

其他相关的 MeSH 术语

其他研究编号

  • Novel rig-S

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅