此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Retention and Wear Characteristic Assessment of OT Equator Smart Box Attachment

2021年1月21日 更新者:Doaa Amr Heshmat、Cairo University

Retention and Wear Characteristic Assessment of OT Equator Smart Box Attachment Versus Ball Attachment for Mandibular Two Implant Assisted Over Denture , In-vitro Study

This research aimed to evaluate the retentive power and wear of the smart box attachment use with tilted two implant assisted mandibular overdenture

研究概览

地位

未知

详细说明

Implant supported overdenture can provide better mastication force than complete denture but less than the normal teeth . Most of the patient reported that implant supported overdenture has many superior features over the conventional complete denture in stability and retention Key factors related to successful treatment with overdentures include the number, location, and distribution of implants and choice of abutment. While the use of parallel implants that are widely distributed is generally desirable for optimal treatment, patients often present with challenging anatomical features, insufficient bone volume in all dimensions, and/or critical anatomy that precludes ideal placement of dental implants. Some clinicians may consider the ideal placement of implants for overdentures as parallel to each other and perpendicular to the occlusal plane of the denture Anatomical features associated with mandibular or maxillary edentulous ridges can range from straight or rounded to irregular and sharp ridges, and variability in bone width may limit potential implant sites for overdentures. Factors such as narrow bone volume, the inferior alveolar nerve being anterior or superior positioned, extensive bony undercuts, the inferior portion of the maxillary sinus, proximity to high-risk vascular structures, or a patient's desire to avoid additional surgical procedures may prompt a clinician to angulate a dental implant, which could result in the positioning of implants in non-ideal configurations.

Excessive angulation, increased maintenance and wear of inserts, and difficulty maintaining hygiene. Increased angulation may result in greater challenges to inserting and removing the prosthesis, which can become difficult for patients who are older and/or have limited dexterity. This challenge also can make it hard for patients to properly clean the inside of the retentive portion of the stud-style abutment and may increase wear of the retentive inserts Resilient Ball attachment most commonly used Ball attachment the simplest of all stud attachments which widely used because it is practical, effective, relatively low cost, less technique sensitive, ease of handling, minimal chair side time requirements and their possible applications with both root and implant-supported prostheses so it is used with non-splinted implants in clinical studies, it has been shown that changes in the retention of the prostheses occurred frequently. Both decrease and considerable increase in retention occurred as a result of attachment abrasion and micro movements during the mastication process The ball attachments showed only a few minor, easy manageable complications. Four out of 36 attachments gave reason for treatment. Two matrices loosened out of the mandibular denture and had to be fastened by adding acrylic resin after 1 and 4 weeks of loading. One patrix part of the ball attachment unsettled after 2 days of loading and was refastened. One ball attachment matrix lost its retention capacity and had to be reactivated after a period of 2 weeks. All these complications occurred in subjects where the implants were not perfectly parallel to each other positioned in the mandible. The loading conditions of these attachments were therefore not as favorable as for more parallel inserted implants A lack of parallelism of the implants creates considerable wear of the rubber rings in a relatively short time span.

Rhein 83, Italy, also has developed Smart Box, which could be used with the OT Equator in patients of extreme divergencies among the implants. The Smart Box has an inner tilting mechanism that enables a passive insertion with divergent implants up to 50 degrees(159).

研究类型

观察性的

注册 (预期的)

10

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 孩子
  • 成人
  • 年长者

接受健康志愿者

不适用

有资格学习的性别

全部

取样方法

概率样本

研究人群

10 mandibular edentolous casts

描述

Inclusion Criteria:

  • mandibular cast

Exclusion Criteria:

-

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
干预/治疗
Equator attachment
Implant installation over epoxy resin model at the canine area on both sides following the surgical protocol of the implant placement,Equator Attachment fabrication is firmly screwed to the fixture on both sides at the canine region
This research aimed to evaluate the retentive power and wear of the smart box attachment use with tilted two implant assisted mandibular overdenture
ball attachment
Implant installation over epoxy resin model at the canine area on both sides following the surgical protocol of the implant placement,ball Attachment fabrication is firmly screwed to the fixture on both sides at the canine region
This research aimed to evaluate the retentive power and wear of the smart box attachment use with tilted two implant assisted mandibular overdenture

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Retention
大体时间:6 month
Retention of OT equator smart box attachment versus ball attachment for mandibular two implant assisted over denture
6 month

次要结果测量

结果测量
措施说明
大体时间
wear evaluation
大体时间:6 month
wear evaluation of OT equator smart box attachment versus ball attachment for
6 month

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (预期的)

2021年2月1日

初级完成 (预期的)

2021年7月1日

研究完成 (预期的)

2021年8月1日

研究注册日期

首次提交

2021年1月16日

首先提交符合 QC 标准的

2021年1月21日

首次发布 (实际的)

2021年1月22日

研究记录更新

最后更新发布 (实际的)

2021年1月22日

上次提交的符合 QC 标准的更新

2021年1月21日

最后验证

2021年1月1日

更多信息

与本研究相关的术语

其他研究编号

  • equator implant attachment

药物和器械信息、研究文件

研究美国 FDA 监管的药品

研究美国 FDA 监管的设备产品

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

dental attachment的临床试验

3
订阅