Retention and Wear Characteristic Assessment of OT Equator Smart Box Attachment
Retention and Wear Characteristic Assessment of OT Equator Smart Box Attachment Versus Ball Attachment for Mandibular Two Implant Assisted Over Denture , In-vitro Study
A tanulmány áttekintése
Részletes leírás
Implant supported overdenture can provide better mastication force than complete denture but less than the normal teeth . Most of the patient reported that implant supported overdenture has many superior features over the conventional complete denture in stability and retention Key factors related to successful treatment with overdentures include the number, location, and distribution of implants and choice of abutment. While the use of parallel implants that are widely distributed is generally desirable for optimal treatment, patients often present with challenging anatomical features, insufficient bone volume in all dimensions, and/or critical anatomy that precludes ideal placement of dental implants. Some clinicians may consider the ideal placement of implants for overdentures as parallel to each other and perpendicular to the occlusal plane of the denture Anatomical features associated with mandibular or maxillary edentulous ridges can range from straight or rounded to irregular and sharp ridges, and variability in bone width may limit potential implant sites for overdentures. Factors such as narrow bone volume, the inferior alveolar nerve being anterior or superior positioned, extensive bony undercuts, the inferior portion of the maxillary sinus, proximity to high-risk vascular structures, or a patient's desire to avoid additional surgical procedures may prompt a clinician to angulate a dental implant, which could result in the positioning of implants in non-ideal configurations.
Excessive angulation, increased maintenance and wear of inserts, and difficulty maintaining hygiene. Increased angulation may result in greater challenges to inserting and removing the prosthesis, which can become difficult for patients who are older and/or have limited dexterity. This challenge also can make it hard for patients to properly clean the inside of the retentive portion of the stud-style abutment and may increase wear of the retentive inserts Resilient Ball attachment most commonly used Ball attachment the simplest of all stud attachments which widely used because it is practical, effective, relatively low cost, less technique sensitive, ease of handling, minimal chair side time requirements and their possible applications with both root and implant-supported prostheses so it is used with non-splinted implants in clinical studies, it has been shown that changes in the retention of the prostheses occurred frequently. Both decrease and considerable increase in retention occurred as a result of attachment abrasion and micro movements during the mastication process The ball attachments showed only a few minor, easy manageable complications. Four out of 36 attachments gave reason for treatment. Two matrices loosened out of the mandibular denture and had to be fastened by adding acrylic resin after 1 and 4 weeks of loading. One patrix part of the ball attachment unsettled after 2 days of loading and was refastened. One ball attachment matrix lost its retention capacity and had to be reactivated after a period of 2 weeks. All these complications occurred in subjects where the implants were not perfectly parallel to each other positioned in the mandible. The loading conditions of these attachments were therefore not as favorable as for more parallel inserted implants A lack of parallelism of the implants creates considerable wear of the rubber rings in a relatively short time span.
Rhein 83, Italy, also has developed Smart Box, which could be used with the OT Equator in patients of extreme divergencies among the implants. The Smart Box has an inner tilting mechanism that enables a passive insertion with divergent implants up to 50 degrees(159).
Tanulmány típusa
Beiratkozás (Várható)
Kapcsolatok és helyek
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
- Gyermek
- Felnőtt
- Idősebb felnőtt
Egészséges önkénteseket fogad
Tanulmányozható nemek
Mintavételi módszer
Tanulmányi populáció
Leírás
Inclusion Criteria:
- mandibular cast
Exclusion Criteria:
-
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
Kohorszok és beavatkozások
Csoport / Kohorsz |
Beavatkozás / kezelés |
---|---|
Equator attachment
Implant installation over epoxy resin model at the canine area on both sides following the surgical protocol of the implant placement,Equator Attachment fabrication is firmly screwed to the fixture on both sides at the canine region
|
This research aimed to evaluate the retentive power and wear of the smart box attachment use with tilted two implant assisted mandibular overdenture
|
ball attachment
Implant installation over epoxy resin model at the canine area on both sides following the surgical protocol of the implant placement,ball Attachment fabrication is firmly screwed to the fixture on both sides at the canine region
|
This research aimed to evaluate the retentive power and wear of the smart box attachment use with tilted two implant assisted mandibular overdenture
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
---|---|---|
Retention
Időkeret: 6 month
|
Retention of OT equator smart box attachment versus ball attachment for mandibular two implant assisted over denture
|
6 month
|
Másodlagos eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
---|---|---|
wear evaluation
Időkeret: 6 month
|
wear evaluation of OT equator smart box attachment versus ball attachment for
|
6 month
|
Együttműködők és nyomozók
Szponzor
Publikációk és hasznos linkek
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete (Várható)
Elsődleges befejezés (Várható)
A tanulmány befejezése (Várható)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Tényleges)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
Kulcsszavak
Egyéb vizsgálati azonosító számok
- equator implant attachment
Gyógyszer- és eszközinformációk, tanulmányi dokumentumok
Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz
Egy amerikai FDA által szabályozott eszközterméket tanulmányoz
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .
Klinikai vizsgálatok a dental attachment
-
New York UniversityUniversity of PennsylvaniaToborzás
-
Biotech DentalToborzásFogbeültetés | Fogászati helyreállítás | Fogászat | Implantátummal támogatott fix protézisFranciaország
-
Solvay Dental 360BefejezveHiányzó fogak | Fogászati viseletEgyesült Államok, Egyesült Királyság
-
Chimei Medical CenterKaohsiung Medical UniversityToborzás2-es típusú diabetes mellitus fogágybetegséggelTajvan
-
Aga Khan UniversityIsmeretlen
-
Kaohsiung Medical University Chung-Ho Memorial...Toborzás2-es típusú diabetes mellitus fogágybetegséggelTajvan
-
New York UniversityBefejezve
-
Meccellis BiotechToborzásFogászati műtétFranciaország
-
Harvard Medical School (HMS and HSDM)BefejezveFájdalom | Érzéstelenítés, helyi
-
University of SalamancaBefejezveFogatlan; Alveoláris folyamat, atrófiaSpanyolország