此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Performance Evaluation of Mpox Molecular POC Diagnostics

Clinical Performance Evaluation of Novel Rapid Molecular Point-of-care (POC) Diagnostics for Mpox Virus

PP016 is a FIND-sponsored retrospective clinical performance study evaluating rapid molecular point-of-care (mPOC) tests for the detection of Mpox virus (MPXV) using archived lesion swab specimens collected in Uganda. Conducted at the Central Public Health Laboratory (CPHL) in Kampala, the study compares up to three investigational assays-Genes2Me VZV-Q, KH Medical RADI-ONE Mpox, and SD Biosensor STANDARD M10 MPX/OPX-against the BioPerfectus laboratory PCR reference test. The primary objective is to determine the sensitivity and specificity of each assay for detecting MPXV in archived positive and negative samples, while secondary analyses assess performance by Ct value and viral clade. The study uses a blinded, non-interventional case-control design with de-identified specimens collected since 2020. Approximately 80 samples per device evaluation are included. PP016 was initiated in response to ongoing mpox outbreaks and the need for accurate decentralized diagnostics in low-resource settings. The study complies with ISO 20916, ICH-GCP principles where applicable, and Ugandan ethical and regulatory requirements, with findings expected to support future regulatory approvals and implementation of rapid mpox diagnostics in low- and middle-income countries

研究概览

地位

完全的

条件

详细说明

PP016 is a FIND-sponsored retrospective, non-interventional clinical performance evaluation study designed to assess the diagnostic accuracy and operational suitability of up to three rapid molecular point-of-care (mPOC) tests for the detection of Mpox virus (MPXV) using archived lesion swab specimens collected in Uganda. The study, titled "Clinical Performance Evaluation of Novel Rapid Molecular Point-of-Care Diagnostics for Mpox Virus," is being conducted at the Central Public Health Laboratory (CPHL) in Kampala, Uganda. The study was developed in response to the growing public health importance of mpox, particularly following the 2022 and 2024 WHO Public Health Emergencies of International Concern (PHEICs), and the ongoing outbreaks affecting several African countries including Uganda, where thousands of confirmed cases have been reported. Because conventional laboratory PCR testing remains centralized and difficult to access in many low-resource or decentralized settings, the study aims to determine whether rapid molecular POC assays can provide accurate and scalable diagnostic alternatives to improve outbreak response, surveillance, patient management, and contact tracing. The study evaluates three investigational molecular diagnostic platforms: the VZV-Q Real-Time PCR Kit for OnePCR (Genes2Me, India), the RADI-ONE Mpox Detection Kit (KH Medical, South Korea), and the STANDARD M10 MPX/OPX assay (SD Biosensor, South Korea). Their performance is compared against the laboratory-based BioPerfectus Monkeypox Virus Real Time PCR Kit, which serves as the reference standard and is currently listed under the African Medicines Regulatory Harmonisation Emergency Use Listing for mpox diagnosis. The study uses archived lesion swab samples stored in viral or universal transport medium from suspected mpox cases collected since 2020 under routine surveillance or prior research activities. Eligible samples must have known PCR status, adequate volume for both reference and index testing, and acceptable storage conditions.

The primary objective is to determine the clinical sensitivity/positive percent agreement (PPA) and specificity/negative percent agreement (NPA) of each investigational assay relative to the reference PCR, while secondary objectives include assessing performance according to PCR cycle threshold (Ct) values as a proxy for viral load and evaluating potential differences in performance by circulating mpox virus clades if such information is available. Statistical analyses will use Wilson score confidence intervals, with subgroup analyses by age, sex, Ct value, and viral clade. The study follows a blinded case-control design in which specimens are de-identified, shuffled, relabeled with unique FIND study identifiers, and tested independently to minimize bias. Reference PCR testing is performed first to confirm specimen quality and classification before testing on the investigational devices. Invalid or inconclusive results are repeated once and documented according to predefined procedures. No patient recruitment or intervention occurs, and test results are not used for clinical management, making the study low risk from an ethical and safety perspective.

Data are collected using OpenClinica Enterprise Edition, a validated electronic data capture system with audit trails and secure cloud hosting. FIND oversees monitoring, quality assurance, operator training, and regulatory compliance throughout the study.

The study is funded by FIND with support from the Government of the Netherlands and is expected to generate independent evidence to support regulatory submissions, procurement decisions, WHO evaluation processes, and future implementation of rapid mpox diagnostics in low- and middle-income countries.

研究类型

观察性的

注册 (实际的)

80

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Buganda Region
      • Kampala、Buganda Region、乌干达
        • National Health Laboratory Services, Central Public Health Laboratory

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 孩子
  • 成人
  • 年长者

接受健康志愿者

不适用

取样方法

概率样本

研究人群

The study population consists of archived skin lesion swabs specimens. These were previously collected from individuals suspected of mpox infection - confirmed by PCR as MPXV positive or negative - under research studies and/or public health surveillance protocols during past and ongoing mpox outbreaks and available in the selected clinical sites.

描述

Inclusion Criteria:

  • Lesion swabs stored in VTM/UTM (non-inactivating)
  • Aliquot with sufficient volume to run the reference PCR and at least one index test (≥2600 μL per pair reference-index tests: ideally at least 1400 μL for 3 index tests and 1200 μL for reference PCR, including 1 possible repeat per test)
  • Available PCR result for specimen selection (i.e. confirmed MPXV positive or negative)
  • Samples collected from 2020 onwards.

Exclusion Criteria:

  • Unknown date of collection
  • >3 freeze-thaw cycles of sample.
  • Samples collected with expired swab collection devices or UTM/VTM

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
干预/治疗
Positive samples
50 confirmed MPXV-positive samples
Each (negative and positive) sample will be tested on the standard of reference and the investigational IVD
Negative samples
30 confirmed MPXV-negative samples
Each (negative and positive) sample will be tested on the standard of reference and the investigational IVD

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Point estimates of sensitivity, specificity, positive and negative predictive value (PPV and NPV respectively) with 95% confidence intervals.
大体时间:July-August 2026
Point estimates of sensitivity, specificity, positive and negative predictive value (PPV and NPV respectively) with 95% confidence intervals.
July-August 2026

次要结果测量

结果测量
措施说明
大体时间
Point estimates of sensitivity/PPA stratified by Ct values of the reference PCR test.
大体时间:July-August 2026
Point estimates of sensitivity/PPA stratified by Ct values of the reference PCR test.
July-August 2026
Point estimates of sensitivity/PPA and specificity/NPA with 95% confidence intervals stratified by virus clade.
大体时间:July-August 2026
Point estimates of sensitivity/PPA and specificity/NPA with 95% confidence intervals stratified by virus clade.
July-August 2026

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2026年6月18日

初级完成 (实际的)

2026年8月31日

研究完成 (实际的)

2026年8月31日

研究注册日期

首次提交

2026年5月27日

首先提交符合 QC 标准的

2026年5月27日

首次发布 (实际的)

2026年6月2日

研究记录更新

最后更新发布 (实际的)

2026年9月4日

上次提交的符合 QC 标准的更新

2026年9月2日

最后验证

2026年9月1日

更多信息

与本研究相关的术语

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.