Performance Evaluation of Mpox Molecular POC Diagnostics
Clinical Performance Evaluation of Novel Rapid Molecular Point-of-care (POC) Diagnostics for Mpox Virus
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
PP016 is a FIND-sponsored retrospective, non-interventional clinical performance evaluation study designed to assess the diagnostic accuracy and operational suitability of up to three rapid molecular point-of-care (mPOC) tests for the detection of Mpox virus (MPXV) using archived lesion swab specimens collected in Uganda. The study, titled "Clinical Performance Evaluation of Novel Rapid Molecular Point-of-Care Diagnostics for Mpox Virus," is being conducted at the Central Public Health Laboratory (CPHL) in Kampala, Uganda. The study was developed in response to the growing public health importance of mpox, particularly following the 2022 and 2024 WHO Public Health Emergencies of International Concern (PHEICs), and the ongoing outbreaks affecting several African countries including Uganda, where thousands of confirmed cases have been reported. Because conventional laboratory PCR testing remains centralized and difficult to access in many low-resource or decentralized settings, the study aims to determine whether rapid molecular POC assays can provide accurate and scalable diagnostic alternatives to improve outbreak response, surveillance, patient management, and contact tracing. The study evaluates three investigational molecular diagnostic platforms: the VZV-Q Real-Time PCR Kit for OnePCR (Genes2Me, India), the RADI-ONE Mpox Detection Kit (KH Medical, South Korea), and the STANDARD M10 MPX/OPX assay (SD Biosensor, South Korea). Their performance is compared against the laboratory-based BioPerfectus Monkeypox Virus Real Time PCR Kit, which serves as the reference standard and is currently listed under the African Medicines Regulatory Harmonisation Emergency Use Listing for mpox diagnosis. The study uses archived lesion swab samples stored in viral or universal transport medium from suspected mpox cases collected since 2020 under routine surveillance or prior research activities. Eligible samples must have known PCR status, adequate volume for both reference and index testing, and acceptable storage conditions.
The primary objective is to determine the clinical sensitivity/positive percent agreement (PPA) and specificity/negative percent agreement (NPA) of each investigational assay relative to the reference PCR, while secondary objectives include assessing performance according to PCR cycle threshold (Ct) values as a proxy for viral load and evaluating potential differences in performance by circulating mpox virus clades if such information is available. Statistical analyses will use Wilson score confidence intervals, with subgroup analyses by age, sex, Ct value, and viral clade. The study follows a blinded case-control design in which specimens are de-identified, shuffled, relabeled with unique FIND study identifiers, and tested independently to minimize bias. Reference PCR testing is performed first to confirm specimen quality and classification before testing on the investigational devices. Invalid or inconclusive results are repeated once and documented according to predefined procedures. No patient recruitment or intervention occurs, and test results are not used for clinical management, making the study low risk from an ethical and safety perspective.
Data are collected using OpenClinica Enterprise Edition, a validated electronic data capture system with audit trails and secure cloud hosting. FIND oversees monitoring, quality assurance, operator training, and regulatory compliance throughout the study.
The study is funded by FIND with support from the Government of the Netherlands and is expected to generate independent evidence to support regulatory submissions, procurement decisions, WHO evaluation processes, and future implementation of rapid mpox diagnostics in low- and middle-income countries.
Tipo de estudio
Inscripción (Estimado)
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
- Niño
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Método de muestreo
Población de estudio
Descripción
Inclusion Criteria:
- Lesion swabs stored in VTM/UTM (non-inactivating)
- Aliquot with sufficient volume to run the reference PCR and at least one index test (≥2600 μL per pair reference-index tests: ideally at least 1400 μL for 3 index tests and 1200 μL for reference PCR, including 1 possible repeat per test)
- Available PCR result for specimen selection (i.e. confirmed MPXV positive or negative)
- Samples collected from 2020 onwards.
Exclusion Criteria:
- Unknown date of collection
- >3 freeze-thaw cycles of sample.
- Samples collected with expired swab collection devices or UTM/VTM
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
Cohortes e Intervenciones
Grupo / Cohorte |
Intervención / Tratamiento |
|---|---|
|
Positive samples
50 confirmed MPXV-positive samples
|
Each (negative and positive) sample will be tested on the standard of reference and the investigational IVD
|
|
Negative samples
30 confirmed MPXV-negative samples
|
Each (negative and positive) sample will be tested on the standard of reference and the investigational IVD
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Point estimates of sensitivity, specificity, positive and negative predictive value (PPV and NPV respectively) with 95% confidence intervals.
Periodo de tiempo: July-August 2026
|
Point estimates of sensitivity, specificity, positive and negative predictive value (PPV and NPV respectively) with 95% confidence intervals.
|
July-August 2026
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Point estimates of sensitivity/PPA stratified by Ct values of the reference PCR test.
Periodo de tiempo: July-August 2026
|
Point estimates of sensitivity/PPA stratified by Ct values of the reference PCR test.
|
July-August 2026
|
|
Point estimates of sensitivity/PPA and specificity/NPA with 95% confidence intervals stratified by virus clade.
Periodo de tiempo: July-August 2026
|
Point estimates of sensitivity/PPA and specificity/NPA with 95% confidence intervals stratified by virus clade.
|
July-August 2026
|
Colaboradores e Investigadores
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Estimado)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- PP016
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .
Ensayos clínicos sobre Viruela del mono
-
Children's Hospital of Fudan UniversityPeople's Hospital of Xinjiang Uygur Autonomous Region; Hainan women and children... y otros colaboradoresTerminadoGama POX de recién nacidos sanos a diferentes altitudes | Umbral de POX para la detección de cardiopatía coronaria mayor en recién nacidosPorcelana
-
Institut PasteurReclutamiento
-
Green Cross CorporationTerminado
Ensayos clínicos sobre MPOX IVD test
-
Genlantis DiagnosticsNorthwestern UniversityAún no reclutandoPara demostrar el rendimiento clínico del dispositivo de diagnóstico invitro TriQuik
-
Samsung ElectronicsNexus DXTerminadoInsuficiencia cardíaca congestivaEstados Unidos
-
Abramson Cancer Center at Penn MedicineTranslational Breast Cancer Research Consortium; Danaher Inc.ReclutamientoCáncer de mama metastásico HER2 positivoEstados Unidos
-
Fundación FLS de Lucha Contra el Sida, las Enfermedades...London School of Hygiene and Tropical Medicine; Hospital Clinic of Barcelona; Germans... y otros colaboradoresTerminadoMpoxEspaña, Perú, Chile, Panamá
-
Firalis SAReclutamiento
-
Chang Gung Memorial HospitalDr. Chip Biotechnology IncorporationTerminadoNeoplasia intraepitelial cervical | Infección por VPH | Infección por el virus del papiloma humanoTaiwán
-
Shepherd Medical CompanyDesconocidoEsterilización MasculinaEstados Unidos
-
Izmir Democracy UniversityAún no reclutandoCapacidad funcionalPavo
-
Methodist Health SystemTerminado
-
University of MiamiUniversity of Tennessee Health Science CenterTerminadoObesidad | Actividad física | Función Cognitiva 1, SocialEstados Unidos