Performance Evaluation of Mpox Molecular POC Diagnostics
Clinical Performance Evaluation of Novel Rapid Molecular Point-of-care (POC) Diagnostics for Mpox Virus
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
PP016 is a FIND-sponsored retrospective, non-interventional clinical performance evaluation study designed to assess the diagnostic accuracy and operational suitability of up to three rapid molecular point-of-care (mPOC) tests for the detection of Mpox virus (MPXV) using archived lesion swab specimens collected in Uganda. The study, titled "Clinical Performance Evaluation of Novel Rapid Molecular Point-of-Care Diagnostics for Mpox Virus," is being conducted at the Central Public Health Laboratory (CPHL) in Kampala, Uganda. The study was developed in response to the growing public health importance of mpox, particularly following the 2022 and 2024 WHO Public Health Emergencies of International Concern (PHEICs), and the ongoing outbreaks affecting several African countries including Uganda, where thousands of confirmed cases have been reported. Because conventional laboratory PCR testing remains centralized and difficult to access in many low-resource or decentralized settings, the study aims to determine whether rapid molecular POC assays can provide accurate and scalable diagnostic alternatives to improve outbreak response, surveillance, patient management, and contact tracing. The study evaluates three investigational molecular diagnostic platforms: the VZV-Q Real-Time PCR Kit for OnePCR (Genes2Me, India), the RADI-ONE Mpox Detection Kit (KH Medical, South Korea), and the STANDARD M10 MPX/OPX assay (SD Biosensor, South Korea). Their performance is compared against the laboratory-based BioPerfectus Monkeypox Virus Real Time PCR Kit, which serves as the reference standard and is currently listed under the African Medicines Regulatory Harmonisation Emergency Use Listing for mpox diagnosis. The study uses archived lesion swab samples stored in viral or universal transport medium from suspected mpox cases collected since 2020 under routine surveillance or prior research activities. Eligible samples must have known PCR status, adequate volume for both reference and index testing, and acceptable storage conditions.
The primary objective is to determine the clinical sensitivity/positive percent agreement (PPA) and specificity/negative percent agreement (NPA) of each investigational assay relative to the reference PCR, while secondary objectives include assessing performance according to PCR cycle threshold (Ct) values as a proxy for viral load and evaluating potential differences in performance by circulating mpox virus clades if such information is available. Statistical analyses will use Wilson score confidence intervals, with subgroup analyses by age, sex, Ct value, and viral clade. The study follows a blinded case-control design in which specimens are de-identified, shuffled, relabeled with unique FIND study identifiers, and tested independently to minimize bias. Reference PCR testing is performed first to confirm specimen quality and classification before testing on the investigational devices. Invalid or inconclusive results are repeated once and documented according to predefined procedures. No patient recruitment or intervention occurs, and test results are not used for clinical management, making the study low risk from an ethical and safety perspective.
Data are collected using OpenClinica Enterprise Edition, a validated electronic data capture system with audit trails and secure cloud hosting. FIND oversees monitoring, quality assurance, operator training, and regulatory compliance throughout the study.
The study is funded by FIND with support from the Government of the Netherlands and is expected to generate independent evidence to support regulatory submissions, procurement decisions, WHO evaluation processes, and future implementation of rapid mpox diagnostics in low- and middle-income countries.
Tipo de estudo
Inscrição (Estimado)
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Filho
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- Lesion swabs stored in VTM/UTM (non-inactivating)
- Aliquot with sufficient volume to run the reference PCR and at least one index test (≥2600 μL per pair reference-index tests: ideally at least 1400 μL for 3 index tests and 1200 μL for reference PCR, including 1 possible repeat per test)
- Available PCR result for specimen selection (i.e. confirmed MPXV positive or negative)
- Samples collected from 2020 onwards.
Exclusion Criteria:
- Unknown date of collection
- >3 freeze-thaw cycles of sample.
- Samples collected with expired swab collection devices or UTM/VTM
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Coortes e Intervenções
Grupo / Coorte |
Intervenção / Tratamento |
|---|---|
|
Positive samples
50 confirmed MPXV-positive samples
|
Each (negative and positive) sample will be tested on the standard of reference and the investigational IVD
|
|
Negative samples
30 confirmed MPXV-negative samples
|
Each (negative and positive) sample will be tested on the standard of reference and the investigational IVD
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Point estimates of sensitivity, specificity, positive and negative predictive value (PPV and NPV respectively) with 95% confidence intervals.
Prazo: July-August 2026
|
Point estimates of sensitivity, specificity, positive and negative predictive value (PPV and NPV respectively) with 95% confidence intervals.
|
July-August 2026
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Point estimates of sensitivity/PPA stratified by Ct values of the reference PCR test.
Prazo: July-August 2026
|
Point estimates of sensitivity/PPA stratified by Ct values of the reference PCR test.
|
July-August 2026
|
|
Point estimates of sensitivity/PPA and specificity/NPA with 95% confidence intervals stratified by virus clade.
Prazo: July-August 2026
|
Point estimates of sensitivity/PPA and specificity/NPA with 95% confidence intervals stratified by virus clade.
|
July-August 2026
|
Colaboradores e Investigadores
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- PP016
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .
Ensaios clínicos em Varíola de macaco
-
Children's Hospital of Fudan UniversityPeople's Hospital of Xinjiang Uygur Autonomous Region; Hainan women and children... e outros colaboradoresConcluídoFaixa POX de recém-nascidos saudáveis em diferentes altitudes | Limite de POX para triagem de CHD grave em neonatosChina
Ensaios clínicos em MPOX IVD test
-
Genlantis DiagnosticsNorthwestern UniversityAinda não está recrutandoPara demonstrar o desempenho clínico do dispositivo de diagnóstico TriQuik Invitro
-
Abramson Cancer Center at Penn MedicineTranslational Breast Cancer Research Consortium; Danaher Inc.RecrutamentoCâncer de Mama Metastático HER2-positivoEstados Unidos
-
Samsung ElectronicsNexus DXRescindidoInsuficiência Cardíaca CongestivaEstados Unidos
-
Fundación FLS de Lucha Contra el Sida, las Enfermedades...London School of Hygiene and Tropical Medicine; Hospital Clinic of Barcelona; Germans... e outros colaboradoresConcluídoMpoxEspanha, Peru, Chile, Panamá
-
Firalis SARecrutamento
-
BioFire Defense LLCEmory University; Wake Forest University Health Sciences; George Washington University e outros colaboradoresRecrutamentoCOVID | Coronavírus | Infecção respiratóriaEstados Unidos
-
Assistance Publique - Hôpitaux de ParisConcluídoVentilação mecânicaFrança
-
Kenya Medical Research InstituteFoundation for Innovative New Diagnostics (FIND)Desconhecido
-
Istinye UniversityConcluídoDerrame | Teleavaliação | O teste Timed Up & Go | Teste de levantar da cadeira de 30 segundosPeru
-
Chang Gung Memorial HospitalDr. Chip Biotechnology IncorporationConcluídoNeoplasia intra-epitelial cervical | Infecção por HPV | Infecção por Papilomavírus HumanoTaiwan