Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Performance Evaluation of Mpox Molecular POC Diagnostics

Clinical Performance Evaluation of Novel Rapid Molecular Point-of-care (POC) Diagnostics for Mpox Virus

PP016 is a FIND-sponsored retrospective clinical performance study evaluating rapid molecular point-of-care (mPOC) tests for the detection of Mpox virus (MPXV) using archived lesion swab specimens collected in Uganda. Conducted at the Central Public Health Laboratory (CPHL) in Kampala, the study compares up to three investigational assays-Genes2Me VZV-Q, KH Medical RADI-ONE Mpox, and SD Biosensor STANDARD M10 MPX/OPX-against the BioPerfectus laboratory PCR reference test. The primary objective is to determine the sensitivity and specificity of each assay for detecting MPXV in archived positive and negative samples, while secondary analyses assess performance by Ct value and viral clade. The study uses a blinded, non-interventional case-control design with de-identified specimens collected since 2020. Approximately 80 samples per device evaluation are included. PP016 was initiated in response to ongoing mpox outbreaks and the need for accurate decentralized diagnostics in low-resource settings. The study complies with ISO 20916, ICH-GCP principles where applicable, and Ugandan ethical and regulatory requirements, with findings expected to support future regulatory approvals and implementation of rapid mpox diagnostics in low- and middle-income countries

Studie Overzicht

Toestand

Nog niet aan het werven

Conditie

Interventie / Behandeling

Gedetailleerde beschrijving

PP016 is a FIND-sponsored retrospective, non-interventional clinical performance evaluation study designed to assess the diagnostic accuracy and operational suitability of up to three rapid molecular point-of-care (mPOC) tests for the detection of Mpox virus (MPXV) using archived lesion swab specimens collected in Uganda. The study, titled "Clinical Performance Evaluation of Novel Rapid Molecular Point-of-Care Diagnostics for Mpox Virus," is being conducted at the Central Public Health Laboratory (CPHL) in Kampala, Uganda. The study was developed in response to the growing public health importance of mpox, particularly following the 2022 and 2024 WHO Public Health Emergencies of International Concern (PHEICs), and the ongoing outbreaks affecting several African countries including Uganda, where thousands of confirmed cases have been reported. Because conventional laboratory PCR testing remains centralized and difficult to access in many low-resource or decentralized settings, the study aims to determine whether rapid molecular POC assays can provide accurate and scalable diagnostic alternatives to improve outbreak response, surveillance, patient management, and contact tracing. The study evaluates three investigational molecular diagnostic platforms: the VZV-Q Real-Time PCR Kit for OnePCR (Genes2Me, India), the RADI-ONE Mpox Detection Kit (KH Medical, South Korea), and the STANDARD M10 MPX/OPX assay (SD Biosensor, South Korea). Their performance is compared against the laboratory-based BioPerfectus Monkeypox Virus Real Time PCR Kit, which serves as the reference standard and is currently listed under the African Medicines Regulatory Harmonisation Emergency Use Listing for mpox diagnosis. The study uses archived lesion swab samples stored in viral or universal transport medium from suspected mpox cases collected since 2020 under routine surveillance or prior research activities. Eligible samples must have known PCR status, adequate volume for both reference and index testing, and acceptable storage conditions.

The primary objective is to determine the clinical sensitivity/positive percent agreement (PPA) and specificity/negative percent agreement (NPA) of each investigational assay relative to the reference PCR, while secondary objectives include assessing performance according to PCR cycle threshold (Ct) values as a proxy for viral load and evaluating potential differences in performance by circulating mpox virus clades if such information is available. Statistical analyses will use Wilson score confidence intervals, with subgroup analyses by age, sex, Ct value, and viral clade. The study follows a blinded case-control design in which specimens are de-identified, shuffled, relabeled with unique FIND study identifiers, and tested independently to minimize bias. Reference PCR testing is performed first to confirm specimen quality and classification before testing on the investigational devices. Invalid or inconclusive results are repeated once and documented according to predefined procedures. No patient recruitment or intervention occurs, and test results are not used for clinical management, making the study low risk from an ethical and safety perspective.

Data are collected using OpenClinica Enterprise Edition, a validated electronic data capture system with audit trails and secure cloud hosting. FIND oversees monitoring, quality assurance, operator training, and regulatory compliance throughout the study.

The study is funded by FIND with support from the Government of the Netherlands and is expected to generate independent evidence to support regulatory submissions, procurement decisions, WHO evaluation processes, and future implementation of rapid mpox diagnostics in low- and middle-income countries.

Studietype

Observationeel

Inschrijving (Geschat)

80

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Kind
  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

NVT

Bemonsteringsmethode

Kanssteekproef

Studie Bevolking

The study population consists of archived skin lesion swabs specimens. These were previously collected from individuals suspected of mpox infection - confirmed by PCR as MPXV positive or negative - under research studies and/or public health surveillance protocols during past and ongoing mpox outbreaks and available in the selected clinical sites.

Beschrijving

Inclusion Criteria:

  • Lesion swabs stored in VTM/UTM (non-inactivating)
  • Aliquot with sufficient volume to run the reference PCR and at least one index test (≥2600 μL per pair reference-index tests: ideally at least 1400 μL for 3 index tests and 1200 μL for reference PCR, including 1 possible repeat per test)
  • Available PCR result for specimen selection (i.e. confirmed MPXV positive or negative)
  • Samples collected from 2020 onwards.

Exclusion Criteria:

  • Unknown date of collection
  • >3 freeze-thaw cycles of sample.
  • Samples collected with expired swab collection devices or UTM/VTM

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

Cohorten en interventies

Groep / Cohort
Interventie / Behandeling
Positive samples
50 confirmed MPXV-positive samples
Each (negative and positive) sample will be tested on the standard of reference and the investigational IVD
Negative samples
30 confirmed MPXV-negative samples
Each (negative and positive) sample will be tested on the standard of reference and the investigational IVD

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Point estimates of sensitivity, specificity, positive and negative predictive value (PPV and NPV respectively) with 95% confidence intervals.
Tijdsspanne: July-August 2026
Point estimates of sensitivity, specificity, positive and negative predictive value (PPV and NPV respectively) with 95% confidence intervals.
July-August 2026

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Point estimates of sensitivity/PPA stratified by Ct values of the reference PCR test.
Tijdsspanne: July-August 2026
Point estimates of sensitivity/PPA stratified by Ct values of the reference PCR test.
July-August 2026
Point estimates of sensitivity/PPA and specificity/NPA with 95% confidence intervals stratified by virus clade.
Tijdsspanne: July-August 2026
Point estimates of sensitivity/PPA and specificity/NPA with 95% confidence intervals stratified by virus clade.
July-August 2026

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Geschat)

15 juni 2026

Primaire voltooiing (Geschat)

15 augustus 2026

Studie voltooiing (Geschat)

15 september 2026

Studieregistratiedata

Eerst ingediend

27 mei 2026

Eerst ingediend dat voldeed aan de QC-criteria

27 mei 2026

Eerst geplaatst (Werkelijk)

2 juni 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

2 juni 2026

Laatste update ingediend die voldeed aan QC-criteria

27 mei 2026

Laatst geverifieerd

1 mei 2026

Meer informatie

Termen gerelateerd aan deze studie

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Klinische onderzoeken op Monkey Pox

Klinische onderzoeken op MPOX IVD test

Abonneren