Performance Evaluation of Mpox Molecular POC Diagnostics

Clinical Performance Evaluation of Novel Rapid Molecular Point-of-care (POC) Diagnostics for Mpox Virus

PP016 is a FIND-sponsored retrospective clinical performance study evaluating rapid molecular point-of-care (mPOC) tests for the detection of Mpox virus (MPXV) using archived lesion swab specimens collected in Uganda. Conducted at the Central Public Health Laboratory (CPHL) in Kampala, the study compares up to three investigational assays-Genes2Me VZV-Q, KH Medical RADI-ONE Mpox, and SD Biosensor STANDARD M10 MPX/OPX-against the BioPerfectus laboratory PCR reference test. The primary objective is to determine the sensitivity and specificity of each assay for detecting MPXV in archived positive and negative samples, while secondary analyses assess performance by Ct value and viral clade. The study uses a blinded, non-interventional case-control design with de-identified specimens collected since 2020. Approximately 80 samples per device evaluation are included. PP016 was initiated in response to ongoing mpox outbreaks and the need for accurate decentralized diagnostics in low-resource settings. The study complies with ISO 20916, ICH-GCP principles where applicable, and Ugandan ethical and regulatory requirements, with findings expected to support future regulatory approvals and implementation of rapid mpox diagnostics in low- and middle-income countries

Studieoversigt

Status

Ikke rekrutterer endnu

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

PP016 is a FIND-sponsored retrospective, non-interventional clinical performance evaluation study designed to assess the diagnostic accuracy and operational suitability of up to three rapid molecular point-of-care (mPOC) tests for the detection of Mpox virus (MPXV) using archived lesion swab specimens collected in Uganda. The study, titled "Clinical Performance Evaluation of Novel Rapid Molecular Point-of-Care Diagnostics for Mpox Virus," is being conducted at the Central Public Health Laboratory (CPHL) in Kampala, Uganda. The study was developed in response to the growing public health importance of mpox, particularly following the 2022 and 2024 WHO Public Health Emergencies of International Concern (PHEICs), and the ongoing outbreaks affecting several African countries including Uganda, where thousands of confirmed cases have been reported. Because conventional laboratory PCR testing remains centralized and difficult to access in many low-resource or decentralized settings, the study aims to determine whether rapid molecular POC assays can provide accurate and scalable diagnostic alternatives to improve outbreak response, surveillance, patient management, and contact tracing. The study evaluates three investigational molecular diagnostic platforms: the VZV-Q Real-Time PCR Kit for OnePCR (Genes2Me, India), the RADI-ONE Mpox Detection Kit (KH Medical, South Korea), and the STANDARD M10 MPX/OPX assay (SD Biosensor, South Korea). Their performance is compared against the laboratory-based BioPerfectus Monkeypox Virus Real Time PCR Kit, which serves as the reference standard and is currently listed under the African Medicines Regulatory Harmonisation Emergency Use Listing for mpox diagnosis. The study uses archived lesion swab samples stored in viral or universal transport medium from suspected mpox cases collected since 2020 under routine surveillance or prior research activities. Eligible samples must have known PCR status, adequate volume for both reference and index testing, and acceptable storage conditions.

The primary objective is to determine the clinical sensitivity/positive percent agreement (PPA) and specificity/negative percent agreement (NPA) of each investigational assay relative to the reference PCR, while secondary objectives include assessing performance according to PCR cycle threshold (Ct) values as a proxy for viral load and evaluating potential differences in performance by circulating mpox virus clades if such information is available. Statistical analyses will use Wilson score confidence intervals, with subgroup analyses by age, sex, Ct value, and viral clade. The study follows a blinded case-control design in which specimens are de-identified, shuffled, relabeled with unique FIND study identifiers, and tested independently to minimize bias. Reference PCR testing is performed first to confirm specimen quality and classification before testing on the investigational devices. Invalid or inconclusive results are repeated once and documented according to predefined procedures. No patient recruitment or intervention occurs, and test results are not used for clinical management, making the study low risk from an ethical and safety perspective.

Data are collected using OpenClinica Enterprise Edition, a validated electronic data capture system with audit trails and secure cloud hosting. FIND oversees monitoring, quality assurance, operator training, and regulatory compliance throughout the study.

The study is funded by FIND with support from the Government of the Netherlands and is expected to generate independent evidence to support regulatory submissions, procurement decisions, WHO evaluation processes, and future implementation of rapid mpox diagnostics in low- and middle-income countries.

Undersøgelsestype

Observationel

Tilmelding (Anslået)

80

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

  • Barn
  • Voksen
  • Ældre voksen

Tager imod sunde frivillige

N/A

Prøveudtagningsmetode

Sandsynlighedsprøve

Studiebefolkning

The study population consists of archived skin lesion swabs specimens. These were previously collected from individuals suspected of mpox infection - confirmed by PCR as MPXV positive or negative - under research studies and/or public health surveillance protocols during past and ongoing mpox outbreaks and available in the selected clinical sites.

Beskrivelse

Inclusion Criteria:

  • Lesion swabs stored in VTM/UTM (non-inactivating)
  • Aliquot with sufficient volume to run the reference PCR and at least one index test (≥2600 μL per pair reference-index tests: ideally at least 1400 μL for 3 index tests and 1200 μL for reference PCR, including 1 possible repeat per test)
  • Available PCR result for specimen selection (i.e. confirmed MPXV positive or negative)
  • Samples collected from 2020 onwards.

Exclusion Criteria:

  • Unknown date of collection
  • >3 freeze-thaw cycles of sample.
  • Samples collected with expired swab collection devices or UTM/VTM

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

Kohorter og interventioner

Gruppe / kohorte
Intervention / Behandling
Positive samples
50 confirmed MPXV-positive samples
Each (negative and positive) sample will be tested on the standard of reference and the investigational IVD
Negative samples
30 confirmed MPXV-negative samples
Each (negative and positive) sample will be tested on the standard of reference and the investigational IVD

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Point estimates of sensitivity, specificity, positive and negative predictive value (PPV and NPV respectively) with 95% confidence intervals.
Tidsramme: July-August 2026
Point estimates of sensitivity, specificity, positive and negative predictive value (PPV and NPV respectively) with 95% confidence intervals.
July-August 2026

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Point estimates of sensitivity/PPA stratified by Ct values of the reference PCR test.
Tidsramme: July-August 2026
Point estimates of sensitivity/PPA stratified by Ct values of the reference PCR test.
July-August 2026
Point estimates of sensitivity/PPA and specificity/NPA with 95% confidence intervals stratified by virus clade.
Tidsramme: July-August 2026
Point estimates of sensitivity/PPA and specificity/NPA with 95% confidence intervals stratified by virus clade.
July-August 2026

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Anslået)

15. juni 2026

Primær færdiggørelse (Anslået)

15. august 2026

Studieafslutning (Anslået)

15. september 2026

Datoer for studieregistrering

Først indsendt

27. maj 2026

Først indsendt, der opfyldte QC-kriterier

27. maj 2026

Først opslået (Faktiske)

2. juni 2026

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

2. juni 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

27. maj 2026

Sidst verificeret

1. maj 2026

Mere information

Begreber relateret til denne undersøgelse

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Abekopper

Kliniske forsøg med MPOX IVD test

Abonner