Comparison of Intraoperative Neuromonitoring With Transcartilaginous Needle Electrodes Versus Endotracheal Tube Electrodes in Thyroid and Parathyroid Surgery
Injury to the recurrent laryngeal nerve (RLN) is among the most important complications in thyroid and parathyroid surgery. Intraoperative neuromonitoring (IONM) of the RLN using electrodes placed on the endotracheal tube is now a standard procedure to facilitate nerve detection and visual identification, to maintain its anatomical and functional integrity and to reduce the rate of nerve injuries. The most common neuromonitoring technique involves the use of electrodes located on the surface of the endotracheal tube, which are in contact with the vocal cords and record the electromyographic signals caused by the electrical stimulation of the RLN by a probe manipulated by the surgeon.
However, this technique has certain disadvantages:
(i) Correct placement of the endotracheal tube is technically demanding and requires an experienced anesthesiologist.
(ii) Improper placement of the tube by the anesthesiologist, its displacement during patient hyperextended neck positioning, intraoperative rotation, or saliva interference between the tube electrodes and the vocal cords may all lead to inability to receive adequate signals and limit the sensitivity of the method.
(iii) Intraoperative readjustment of the tube position can be time-consuming and difficult.
The above neuromonitoring method is associated with a high negative predictive value (92-100%) according to the literature. However, its positive predictive value ranges between 10% and 90% which means that in the case of a decrease or loss of the initial neurostimulation signal, the true injury of the RLN is 10-90%.
Neuromonitoring with intraoperative placement of electrodes in the thyroid cartilage is an alternative method, in which the electrodes are placed by the surgeon in the perichondrium of the thyroid cartilage at the beginning of the operation. Their placement is simple, with almost no learning curve and does not require further preparation of the surrounding structures. Similarly to the endotracheal tube electrode, these also record the electromyografic signal from the electrical stimulation of the laryngeal muscles and RLN, however they are more sensitive in detecting the movement of the vocal cords and can potentially record a higher and more stable neurostimulation signal. In this way, the rate of false positive signal loss could be reduced compared to the technique of neuromonitoring with the electrodes on the endotracheal tube.
This PhD thesis aims to evaluate the effectiveness and reliability of neuromonitoring with transcartilaginous needle electrodes versus endotracheal tube electrodes in thyroid and parathyroid surgeries. It is a prospective multicenter study of diagnostic accuracy, with paired design, of the neuromonitoring signals (amplitude - latency), which will be obtained based on the standard algorithm V1, R1, EBSLN1, EBSLN2, R2, V2, before and after the end of the manipulations in each thyroid lobe, using both aforementioned techniques. Their positive and negative predictive value will be compared and evaluated with regard to the injury of the recurrent laryngeal nerve. To achieve the above, at least 300 patients who will undergo thyroid or parathyroid gland surgery will be evaluated and intraoperatively will undergo neuromonitoring with both methods. After the surgery, on the 1st postoperative day, all patients will undergo laryngoscopy to exclude or confirm injury of the RLN.
研究概览
地位
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习地点
-
-
-
Thessaloniki、希腊
- 2nd Surgical Department of Aristotle University of Thessaloniki
-
-
参与标准
资格标准
适合学习的年龄
- 孩子
- 成人
- 年长者
接受健康志愿者
描述
Inclusion Criteria:
- Age ≥ 18 years
- Patients undergoing thyroidectomy or parathyroidectomy via cervical incision
- Signed informed consent
Exclusion Criteria:
- Age < 18 years
- Remote access thyroidectomy or parathyroidectomy
- Presence of thyroglossal duct cyst
学习计划
研究是如何设计的?
设计细节
- 主要用途:诊断
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
有源比较器:Endocrine surgery patients
All the patients submited to thyroid and/or parathyroid surgey will undergo intraoperative neuromonitoring with transcartilaginous needle electrodes and endotracheal tube electrodes at the same time
|
This study aims to evaluate the effectiveness and reliability of neuromonitoring with transcartilaginous needle electrodes versus endotracheal tube electrodes in thyroid and parathyroid surgeries. It is a prospective study of diagnostic accuracy, with paired design, of the neuromonitoring signals (amplitude - latency), which will be obtained based on the standard algorithm V1, R1, EBSLN1, EBSLN2, R2, V2, before and after the end of the manipulations in each thyroid lobe, using both aforementioned techniques. Their positive and negative predictive value will be compared and evaluated with regard to the injury of the recurrent laryngeal nerve. After the surgery, on the 1st postoperative day, all patients will undergo laryngoscopy to exclude or confirm injury of the RLN. It is the first study that evaluates simultaneously both intraoperative neuromonitoring methods in the same patient and at such large group of patients. |
研究衡量的是什么?
主要结果指标
结果测量 |
大体时间 |
|---|---|
|
positive predictive value
大体时间:during surgery
|
during surgery
|
合作者和调查者
调查人员
- 学习椅:Stefanos Atmatzidis, Assistant Professor of Surgery、2nd Surgical Department of Aristotle University of Thessaloniki
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- 5402-2207-2025
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
IPD 共享时间框架
IPD 共享支持信息类型
- 研究方案
- 国际碳纤维联合会
- 企业社会责任
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.