- ICH GCP
- US Clinical Trials Registry
- Klinisk forsøg NCT07638579
Comparison of Intraoperative Neuromonitoring With Transcartilaginous Needle Electrodes Versus Endotracheal Tube Electrodes in Thyroid and Parathyroid Surgery
Injury to the recurrent laryngeal nerve (RLN) is among the most important complications in thyroid and parathyroid surgery. Intraoperative neuromonitoring (IONM) of the RLN using electrodes placed on the endotracheal tube is now a standard procedure to facilitate nerve detection and visual identification, to maintain its anatomical and functional integrity and to reduce the rate of nerve injuries. The most common neuromonitoring technique involves the use of electrodes located on the surface of the endotracheal tube, which are in contact with the vocal cords and record the electromyographic signals caused by the electrical stimulation of the RLN by a probe manipulated by the surgeon.
However, this technique has certain disadvantages:
(i) Correct placement of the endotracheal tube is technically demanding and requires an experienced anesthesiologist.
(ii) Improper placement of the tube by the anesthesiologist, its displacement during patient hyperextended neck positioning, intraoperative rotation, or saliva interference between the tube electrodes and the vocal cords may all lead to inability to receive adequate signals and limit the sensitivity of the method.
(iii) Intraoperative readjustment of the tube position can be time-consuming and difficult.
The above neuromonitoring method is associated with a high negative predictive value (92-100%) according to the literature. However, its positive predictive value ranges between 10% and 90% which means that in the case of a decrease or loss of the initial neurostimulation signal, the true injury of the RLN is 10-90%.
Neuromonitoring with intraoperative placement of electrodes in the thyroid cartilage is an alternative method, in which the electrodes are placed by the surgeon in the perichondrium of the thyroid cartilage at the beginning of the operation. Their placement is simple, with almost no learning curve and does not require further preparation of the surrounding structures. Similarly to the endotracheal tube electrode, these also record the electromyografic signal from the electrical stimulation of the laryngeal muscles and RLN, however they are more sensitive in detecting the movement of the vocal cords and can potentially record a higher and more stable neurostimulation signal. In this way, the rate of false positive signal loss could be reduced compared to the technique of neuromonitoring with the electrodes on the endotracheal tube.
This PhD thesis aims to evaluate the effectiveness and reliability of neuromonitoring with transcartilaginous needle electrodes versus endotracheal tube electrodes in thyroid and parathyroid surgeries. It is a prospective multicenter study of diagnostic accuracy, with paired design, of the neuromonitoring signals (amplitude - latency), which will be obtained based on the standard algorithm V1, R1, EBSLN1, EBSLN2, R2, V2, before and after the end of the manipulations in each thyroid lobe, using both aforementioned techniques. Their positive and negative predictive value will be compared and evaluated with regard to the injury of the recurrent laryngeal nerve. To achieve the above, at least 300 patients who will undergo thyroid or parathyroid gland surgery will be evaluated and intraoperatively will undergo neuromonitoring with both methods. After the surgery, on the 1st postoperative day, all patients will undergo laryngoscopy to exclude or confirm injury of the RLN.
Studieoversigt
Status
Betingelser
Undersøgelsestype
Tilmelding (Anslået)
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiesteder
-
-
-
Thessaloniki, Grækenland
- 2nd Surgical Department of Aristotle University of Thessaloniki
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
- Barn
- Voksen
- Ældre voksen
Tager imod sunde frivillige
Beskrivelse
Inclusion Criteria:
- Age ≥ 18 years
- Patients undergoing thyroidectomy or parathyroidectomy via cervical incision
- Signed informed consent
Exclusion Criteria:
- Age < 18 years
- Remote access thyroidectomy or parathyroidectomy
- Presence of thyroglossal duct cyst
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Diagnostisk
- Tildeling: N/A
- Interventionel model: Enkelt gruppeopgave
- Maskning: Ingen (Åben etiket)
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Aktiv komparator: Endocrine surgery patients
All the patients submited to thyroid and/or parathyroid surgey will undergo intraoperative neuromonitoring with transcartilaginous needle electrodes and endotracheal tube electrodes at the same time
|
This study aims to evaluate the effectiveness and reliability of neuromonitoring with transcartilaginous needle electrodes versus endotracheal tube electrodes in thyroid and parathyroid surgeries. It is a prospective study of diagnostic accuracy, with paired design, of the neuromonitoring signals (amplitude - latency), which will be obtained based on the standard algorithm V1, R1, EBSLN1, EBSLN2, R2, V2, before and after the end of the manipulations in each thyroid lobe, using both aforementioned techniques. Their positive and negative predictive value will be compared and evaluated with regard to the injury of the recurrent laryngeal nerve. After the surgery, on the 1st postoperative day, all patients will undergo laryngoscopy to exclude or confirm injury of the RLN. It is the first study that evaluates simultaneously both intraoperative neuromonitoring methods in the same patient and at such large group of patients. |
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
positive predictive value
Tidsramme: during surgery
|
during surgery
|
Samarbejdspartnere og efterforskere
Efterforskere
- Studiestol: Stefanos Atmatzidis, Assistant Professor of Surgery, 2nd Surgical Department of Aristotle University of Thessaloniki
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Primær færdiggørelse (Anslået)
Studieafslutning (Anslået)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
- 5402-2207-2025
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
IPD-planbeskrivelse
IPD-delingstidsramme
IPD-deling Understøttende informationstype
- STUDY_PROTOCOL
- ICF
- CSR
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .