- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07638579
Comparison of Intraoperative Neuromonitoring With Transcartilaginous Needle Electrodes Versus Endotracheal Tube Electrodes in Thyroid and Parathyroid Surgery
Injury to the recurrent laryngeal nerve (RLN) is among the most important complications in thyroid and parathyroid surgery. Intraoperative neuromonitoring (IONM) of the RLN using electrodes placed on the endotracheal tube is now a standard procedure to facilitate nerve detection and visual identification, to maintain its anatomical and functional integrity and to reduce the rate of nerve injuries. The most common neuromonitoring technique involves the use of electrodes located on the surface of the endotracheal tube, which are in contact with the vocal cords and record the electromyographic signals caused by the electrical stimulation of the RLN by a probe manipulated by the surgeon.
However, this technique has certain disadvantages:
(i) Correct placement of the endotracheal tube is technically demanding and requires an experienced anesthesiologist.
(ii) Improper placement of the tube by the anesthesiologist, its displacement during patient hyperextended neck positioning, intraoperative rotation, or saliva interference between the tube electrodes and the vocal cords may all lead to inability to receive adequate signals and limit the sensitivity of the method.
(iii) Intraoperative readjustment of the tube position can be time-consuming and difficult.
The above neuromonitoring method is associated with a high negative predictive value (92-100%) according to the literature. However, its positive predictive value ranges between 10% and 90% which means that in the case of a decrease or loss of the initial neurostimulation signal, the true injury of the RLN is 10-90%.
Neuromonitoring with intraoperative placement of electrodes in the thyroid cartilage is an alternative method, in which the electrodes are placed by the surgeon in the perichondrium of the thyroid cartilage at the beginning of the operation. Their placement is simple, with almost no learning curve and does not require further preparation of the surrounding structures. Similarly to the endotracheal tube electrode, these also record the electromyografic signal from the electrical stimulation of the laryngeal muscles and RLN, however they are more sensitive in detecting the movement of the vocal cords and can potentially record a higher and more stable neurostimulation signal. In this way, the rate of false positive signal loss could be reduced compared to the technique of neuromonitoring with the electrodes on the endotracheal tube.
This PhD thesis aims to evaluate the effectiveness and reliability of neuromonitoring with transcartilaginous needle electrodes versus endotracheal tube electrodes in thyroid and parathyroid surgeries. It is a prospective multicenter study of diagnostic accuracy, with paired design, of the neuromonitoring signals (amplitude - latency), which will be obtained based on the standard algorithm V1, R1, EBSLN1, EBSLN2, R2, V2, before and after the end of the manipulations in each thyroid lobe, using both aforementioned techniques. Their positive and negative predictive value will be compared and evaluated with regard to the injury of the recurrent laryngeal nerve. To achieve the above, at least 300 patients who will undergo thyroid or parathyroid gland surgery will be evaluated and intraoperatively will undergo neuromonitoring with both methods. After the surgery, on the 1st postoperative day, all patients will undergo laryngoscopy to exclude or confirm injury of the RLN.
Aperçu de l'étude
Statut
Les conditions
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
-
Thessaloniki, Grèce
- 2nd Surgical Department of Aristotle University of Thessaloniki
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Enfant
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
La description
Inclusion Criteria:
- Age ≥ 18 years
- Patients undergoing thyroidectomy or parathyroidectomy via cervical incision
- Signed informed consent
Exclusion Criteria:
- Age < 18 years
- Remote access thyroidectomy or parathyroidectomy
- Presence of thyroglossal duct cyst
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Comparateur actif: Endocrine surgery patients
All the patients submited to thyroid and/or parathyroid surgey will undergo intraoperative neuromonitoring with transcartilaginous needle electrodes and endotracheal tube electrodes at the same time
|
This study aims to evaluate the effectiveness and reliability of neuromonitoring with transcartilaginous needle electrodes versus endotracheal tube electrodes in thyroid and parathyroid surgeries. It is a prospective study of diagnostic accuracy, with paired design, of the neuromonitoring signals (amplitude - latency), which will be obtained based on the standard algorithm V1, R1, EBSLN1, EBSLN2, R2, V2, before and after the end of the manipulations in each thyroid lobe, using both aforementioned techniques. Their positive and negative predictive value will be compared and evaluated with regard to the injury of the recurrent laryngeal nerve. After the surgery, on the 1st postoperative day, all patients will undergo laryngoscopy to exclude or confirm injury of the RLN. It is the first study that evaluates simultaneously both intraoperative neuromonitoring methods in the same patient and at such large group of patients. |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Délai |
|---|---|
|
positive predictive value
Délai: during surgery
|
during surgery
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chaise d'étude: Stefanos Atmatzidis, Assistant Professor of Surgery, 2nd Surgical Department of Aristotle University of Thessaloniki
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- 5402-2207-2025
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Description du régime IPD
Délai de partage IPD
Type d'informations de prise en charge du partage d'IPD
- PROTOCOLE D'ÉTUDE
- CIF
- RSE
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .