Bedside Ultrasound for Confirmation of Endotracheal Tube Placement in the Emergency Department
The Role of Bedside Ultrasound in Confirming Endotracheal Tube Placement in Patients Undergoing Endotracheal Intubation in the Emergency Department
This prospective observational study evaluated the role of bedside ultrasound in confirming endotracheal tube placement in adult patients who underwent endotracheal intubation in the emergency department. Correct placement of the endotracheal tube is critical because unrecognized incorrect placement may cause hypoxemia, hypoxic brain injury, or death.
In this study, bedside ultrasound was performed during or immediately after endotracheal intubation without interfering with the intubation procedure. Ultrasound findings were compared with capnographic end-tidal carbon dioxide measurement, which was used as the reference method for confirming tube placement. The main aim was to assess whether bedside ultrasound is a useful and reliable method for confirming endotracheal tube position in emergency department patients.
研究概览
详细说明
This single-center, prospective observational diagnostic accuracy study was conducted in the Emergency Department of Antalya Training and Research Hospital. Adult patients who underwent endotracheal intubation in the emergency department after ethics committee approval were included.
Endotracheal intubation was performed as part of routine emergency care by the most senior emergency medicine resident or an experienced emergency physician. Bedside ultrasound assessment was performed during or immediately after intubation by trained emergency physicians without interrupting or delaying the intubation procedure. The ultrasound examination was performed from the suprasternal notch region to assess the position of the endotracheal tube.
The physicians who performed bedside ultrasound had at least two years of emergency medicine experience and had completed accredited ultrasound training. Before study data collection, they received additional theoretical and practical training focused on ultrasound confirmation of endotracheal tube placement.
Ultrasound findings were compared with capnometric end-tidal carbon dioxide measurement, which was used as the reference method for confirmation of endotracheal tube placement. Ultrasound images were stored in the hospital computer system and reviewed by two qualified, independent radiology specialists. Images or measurements with insufficient quality were excluded from analysis. Agreement between ultrasound assessments was evaluated statistically.
The study aimed to determine whether bedside ultrasound can be used as a rapid, reliable, and practical method for confirming endotracheal tube placement in emergency department patients.
研究类型
注册 (实际的)
联系人和位置
学习地点
-
-
konyaaltı
-
Antalya、konyaaltı、土耳其(türkiye)、07100
- University of Health Sciences, Antalya Training and Research Hospital
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
取样方法
研究人群
描述
Inclusion Criteria:
- Patients aged 18 years or older
- Patients who underwent endotracheal intubation in the emergency department as part of routine emergency care
- Patients in whom bedside ultrasound and capnometric end-tidal carbon dioxide assessment were performed for confirmation of endotracheal tube placement
Exclusion Criteria:
- Patients younger than 18 years of age
- Patients with missing or incomplete study data
- Patients with ultrasound images of insufficient quality for evaluation
学习计划
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
|---|
|
Patients Undergoing Endotracheal Intubation in the Emergency Department
Adult patients who underwent endotracheal intubation in the emergency department were included in this cohort.
Endotracheal intubation was performed as part of routine emergency care.
Bedside ultrasound was performed during or immediately after intubation by trained emergency physicians without interrupting the procedure.
Ultrasound findings were compared with capnometric end-tidal carbon dioxide measurement, which was used as the reference method for confirming endotracheal tube placement.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Diagnostic Accuracy of Bedside Ultrasound for Confirmation of Endotracheal Tube Placement
大体时间:During or immediately after endotracheal intubation, within a maximum of 20 seconds
|
The diagnostic accuracy of bedside ultrasound for confirming endotracheal tube placement will be evaluated by comparing ultrasound findings with capnometric end-tidal carbon dioxide measurement, which will be used as the reference method.
Diagnostic performance will be assessed using sensitivity, specificity, positive predictive value, negative predictive value, overall accuracy, and agreement with the reference method.
|
During or immediately after endotracheal intubation, within a maximum of 20 seconds
|
合作者和调查者
调查人员
- 首席研究员:MURAT DUYAN, ASSOCIATE PROFESSOR、University of Health Sciences, Antalya Training and Research Hospital
- 研究主任:HALIT EKICI, MEDICAL DOCTOR、University of Health Sciences, Antalya Training and Research Hospital
- 研究主任:CEMIL KAVALCI, PROFESSOR、University of Health Sciences, Antalya Training and Research Hospital
- 研究主任:ENGIN DENIZ ARSLAN, ASSOCIATE PROFESSOR、University of Health Sciences, Antalya Training and Research Hospital
- 研究主任:FEVZI YILMAZ、University of Health Sciences, Antalya Training and Research Hospital
出版物和有用的链接
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- 2025-019
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.