此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Bedside Ultrasound for Confirmation of Endotracheal Tube Placement in the Emergency Department

2026年6月20日 更新者:Antalya Health Sciences University

The Role of Bedside Ultrasound in Confirming Endotracheal Tube Placement in Patients Undergoing Endotracheal Intubation in the Emergency Department

This prospective observational study evaluated the role of bedside ultrasound in confirming endotracheal tube placement in adult patients who underwent endotracheal intubation in the emergency department. Correct placement of the endotracheal tube is critical because unrecognized incorrect placement may cause hypoxemia, hypoxic brain injury, or death.

In this study, bedside ultrasound was performed during or immediately after endotracheal intubation without interfering with the intubation procedure. Ultrasound findings were compared with capnographic end-tidal carbon dioxide measurement, which was used as the reference method for confirming tube placement. The main aim was to assess whether bedside ultrasound is a useful and reliable method for confirming endotracheal tube position in emergency department patients.

研究概览

详细说明

This single-center, prospective observational diagnostic accuracy study was conducted in the Emergency Department of Antalya Training and Research Hospital. Adult patients who underwent endotracheal intubation in the emergency department after ethics committee approval were included.

Endotracheal intubation was performed as part of routine emergency care by the most senior emergency medicine resident or an experienced emergency physician. Bedside ultrasound assessment was performed during or immediately after intubation by trained emergency physicians without interrupting or delaying the intubation procedure. The ultrasound examination was performed from the suprasternal notch region to assess the position of the endotracheal tube.

The physicians who performed bedside ultrasound had at least two years of emergency medicine experience and had completed accredited ultrasound training. Before study data collection, they received additional theoretical and practical training focused on ultrasound confirmation of endotracheal tube placement.

Ultrasound findings were compared with capnometric end-tidal carbon dioxide measurement, which was used as the reference method for confirmation of endotracheal tube placement. Ultrasound images were stored in the hospital computer system and reviewed by two qualified, independent radiology specialists. Images or measurements with insufficient quality were excluded from analysis. Agreement between ultrasound assessments was evaluated statistically.

The study aimed to determine whether bedside ultrasound can be used as a rapid, reliable, and practical method for confirming endotracheal tube placement in emergency department patients.

研究类型

观察性的

注册 (实际的)

70

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • konyaaltı
      • Antalya、konyaaltı、土耳其(türkiye)、07100
        • University of Health Sciences, Antalya Training and Research Hospital

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不

取样方法

非概率样本

研究人群

The study population consisted of adult patients aged 18 years or older who presented to the Emergency Department of Antalya Training and Research Hospital and underwent endotracheal intubation as part of routine emergency care. Patients were included after ethics committee approval if bedside ultrasound and capnometric end-tidal carbon dioxide assessment were performed for confirmation of endotracheal tube placement.

描述

Inclusion Criteria:

  • Patients aged 18 years or older
  • Patients who underwent endotracheal intubation in the emergency department as part of routine emergency care
  • Patients in whom bedside ultrasound and capnometric end-tidal carbon dioxide assessment were performed for confirmation of endotracheal tube placement

Exclusion Criteria:

  • Patients younger than 18 years of age
  • Patients with missing or incomplete study data
  • Patients with ultrasound images of insufficient quality for evaluation

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
Patients Undergoing Endotracheal Intubation in the Emergency Department
Adult patients who underwent endotracheal intubation in the emergency department were included in this cohort. Endotracheal intubation was performed as part of routine emergency care. Bedside ultrasound was performed during or immediately after intubation by trained emergency physicians without interrupting the procedure. Ultrasound findings were compared with capnometric end-tidal carbon dioxide measurement, which was used as the reference method for confirming endotracheal tube placement.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Diagnostic Accuracy of Bedside Ultrasound for Confirmation of Endotracheal Tube Placement
大体时间:During or immediately after endotracheal intubation, within a maximum of 20 seconds
The diagnostic accuracy of bedside ultrasound for confirming endotracheal tube placement will be evaluated by comparing ultrasound findings with capnometric end-tidal carbon dioxide measurement, which will be used as the reference method. Diagnostic performance will be assessed using sensitivity, specificity, positive predictive value, negative predictive value, overall accuracy, and agreement with the reference method.
During or immediately after endotracheal intubation, within a maximum of 20 seconds

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:MURAT DUYAN, ASSOCIATE PROFESSOR、University of Health Sciences, Antalya Training and Research Hospital
  • 研究主任:HALIT EKICI, MEDICAL DOCTOR、University of Health Sciences, Antalya Training and Research Hospital
  • 研究主任:CEMIL KAVALCI, PROFESSOR、University of Health Sciences, Antalya Training and Research Hospital
  • 研究主任:ENGIN DENIZ ARSLAN, ASSOCIATE PROFESSOR、University of Health Sciences, Antalya Training and Research Hospital
  • 研究主任:FEVZI YILMAZ、University of Health Sciences, Antalya Training and Research Hospital

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2025年1月10日

初级完成 (实际的)

2026年6月10日

研究完成 (实际的)

2026年6月10日

研究注册日期

首次提交

2026年6月20日

首先提交符合 QC 标准的

2026年6月20日

首次发布 (实际的)

2026年6月25日

研究记录更新

最后更新发布 (实际的)

2026年6月25日

上次提交的符合 QC 标准的更新

2026年6月20日

最后验证

2026年6月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

IPD 计划说明

Individual participant data will not be shared publicly because the study includes clinical data from emergency department patients and there may be confidentiality and institutional restrictions. De-identified aggregate results will be reported in scientific publications.

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅