Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Bedside Ultrasound for Confirmation of Endotracheal Tube Placement in the Emergency Department

20. Juni 2026 aktualisiert von: Antalya Health Sciences University

The Role of Bedside Ultrasound in Confirming Endotracheal Tube Placement in Patients Undergoing Endotracheal Intubation in the Emergency Department

This prospective observational study evaluated the role of bedside ultrasound in confirming endotracheal tube placement in adult patients who underwent endotracheal intubation in the emergency department. Correct placement of the endotracheal tube is critical because unrecognized incorrect placement may cause hypoxemia, hypoxic brain injury, or death.

In this study, bedside ultrasound was performed during or immediately after endotracheal intubation without interfering with the intubation procedure. Ultrasound findings were compared with capnographic end-tidal carbon dioxide measurement, which was used as the reference method for confirming tube placement. The main aim was to assess whether bedside ultrasound is a useful and reliable method for confirming endotracheal tube position in emergency department patients.

Studienübersicht

Detaillierte Beschreibung

This single-center, prospective observational diagnostic accuracy study was conducted in the Emergency Department of Antalya Training and Research Hospital. Adult patients who underwent endotracheal intubation in the emergency department after ethics committee approval were included.

Endotracheal intubation was performed as part of routine emergency care by the most senior emergency medicine resident or an experienced emergency physician. Bedside ultrasound assessment was performed during or immediately after intubation by trained emergency physicians without interrupting or delaying the intubation procedure. The ultrasound examination was performed from the suprasternal notch region to assess the position of the endotracheal tube.

The physicians who performed bedside ultrasound had at least two years of emergency medicine experience and had completed accredited ultrasound training. Before study data collection, they received additional theoretical and practical training focused on ultrasound confirmation of endotracheal tube placement.

Ultrasound findings were compared with capnometric end-tidal carbon dioxide measurement, which was used as the reference method for confirmation of endotracheal tube placement. Ultrasound images were stored in the hospital computer system and reviewed by two qualified, independent radiology specialists. Images or measurements with insufficient quality were excluded from analysis. Agreement between ultrasound assessments was evaluated statistically.

The study aimed to determine whether bedside ultrasound can be used as a rapid, reliable, and practical method for confirming endotracheal tube placement in emergency department patients.

Studientyp

Beobachtungs

Einschreibung (Tatsächlich)

70

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

    • konyaaltı
      • Antalya, konyaaltı, Türkei (türkiye), 07100
        • University of Health Sciences, Antalya Training and Research Hospital

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Nein

Probenahmeverfahren

Nicht-Wahrscheinlichkeitsprobe

Studienpopulation

The study population consisted of adult patients aged 18 years or older who presented to the Emergency Department of Antalya Training and Research Hospital and underwent endotracheal intubation as part of routine emergency care. Patients were included after ethics committee approval if bedside ultrasound and capnometric end-tidal carbon dioxide assessment were performed for confirmation of endotracheal tube placement.

Beschreibung

Inclusion Criteria:

  • Patients aged 18 years or older
  • Patients who underwent endotracheal intubation in the emergency department as part of routine emergency care
  • Patients in whom bedside ultrasound and capnometric end-tidal carbon dioxide assessment were performed for confirmation of endotracheal tube placement

Exclusion Criteria:

  • Patients younger than 18 years of age
  • Patients with missing or incomplete study data
  • Patients with ultrasound images of insufficient quality for evaluation

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

Kohorten und Interventionen

Gruppe / Kohorte
Patients Undergoing Endotracheal Intubation in the Emergency Department
Adult patients who underwent endotracheal intubation in the emergency department were included in this cohort. Endotracheal intubation was performed as part of routine emergency care. Bedside ultrasound was performed during or immediately after intubation by trained emergency physicians without interrupting the procedure. Ultrasound findings were compared with capnometric end-tidal carbon dioxide measurement, which was used as the reference method for confirming endotracheal tube placement.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Diagnostic Accuracy of Bedside Ultrasound for Confirmation of Endotracheal Tube Placement
Zeitfenster: During or immediately after endotracheal intubation, within a maximum of 20 seconds
The diagnostic accuracy of bedside ultrasound for confirming endotracheal tube placement will be evaluated by comparing ultrasound findings with capnometric end-tidal carbon dioxide measurement, which will be used as the reference method. Diagnostic performance will be assessed using sensitivity, specificity, positive predictive value, negative predictive value, overall accuracy, and agreement with the reference method.
During or immediately after endotracheal intubation, within a maximum of 20 seconds

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Ermittler

  • Hauptermittler: MURAT DUYAN, ASSOCIATE PROFESSOR, University of Health Sciences, Antalya Training and Research Hospital
  • Studienleiter: HALIT EKICI, MEDICAL DOCTOR, University of Health Sciences, Antalya Training and Research Hospital
  • Studienleiter: CEMIL KAVALCI, PROFESSOR, University of Health Sciences, Antalya Training and Research Hospital
  • Studienleiter: ENGIN DENIZ ARSLAN, ASSOCIATE PROFESSOR, University of Health Sciences, Antalya Training and Research Hospital
  • Studienleiter: FEVZI YILMAZ, University of Health Sciences, Antalya Training and Research Hospital

Publikationen und hilfreiche Links

Die Bereitstellung dieser Publikationen erfolgt freiwillig durch die für die Eingabe von Informationen über die Studie verantwortliche Person. Diese können sich auf alles beziehen, was mit dem Studium zu tun hat.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

10. Januar 2025

Primärer Abschluss (Tatsächlich)

10. Juni 2026

Studienabschluss (Tatsächlich)

10. Juni 2026

Studienanmeldedaten

Zuerst eingereicht

20. Juni 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

20. Juni 2026

Zuerst gepostet (Tatsächlich)

25. Juni 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

25. Juni 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

20. Juni 2026

Zuletzt verifiziert

1. Juni 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Beschreibung des IPD-Plans

Individual participant data will not be shared publicly because the study includes clinical data from emergency department patients and there may be confidentiality and institutional restrictions. De-identified aggregate results will be reported in scientific publications.

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur Endotracheale Intubation

3