- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07669259
Bedside Ultrasound for Confirmation of Endotracheal Tube Placement in the Emergency Department
The Role of Bedside Ultrasound in Confirming Endotracheal Tube Placement in Patients Undergoing Endotracheal Intubation in the Emergency Department
This prospective observational study evaluated the role of bedside ultrasound in confirming endotracheal tube placement in adult patients who underwent endotracheal intubation in the emergency department. Correct placement of the endotracheal tube is critical because unrecognized incorrect placement may cause hypoxemia, hypoxic brain injury, or death.
In this study, bedside ultrasound was performed during or immediately after endotracheal intubation without interfering with the intubation procedure. Ultrasound findings were compared with capnographic end-tidal carbon dioxide measurement, which was used as the reference method for confirming tube placement. The main aim was to assess whether bedside ultrasound is a useful and reliable method for confirming endotracheal tube position in emergency department patients.
Studie Overzicht
Toestand
Gedetailleerde beschrijving
This single-center, prospective observational diagnostic accuracy study was conducted in the Emergency Department of Antalya Training and Research Hospital. Adult patients who underwent endotracheal intubation in the emergency department after ethics committee approval were included.
Endotracheal intubation was performed as part of routine emergency care by the most senior emergency medicine resident or an experienced emergency physician. Bedside ultrasound assessment was performed during or immediately after intubation by trained emergency physicians without interrupting or delaying the intubation procedure. The ultrasound examination was performed from the suprasternal notch region to assess the position of the endotracheal tube.
The physicians who performed bedside ultrasound had at least two years of emergency medicine experience and had completed accredited ultrasound training. Before study data collection, they received additional theoretical and practical training focused on ultrasound confirmation of endotracheal tube placement.
Ultrasound findings were compared with capnometric end-tidal carbon dioxide measurement, which was used as the reference method for confirmation of endotracheal tube placement. Ultrasound images were stored in the hospital computer system and reviewed by two qualified, independent radiology specialists. Images or measurements with insufficient quality were excluded from analysis. Agreement between ultrasound assessments was evaluated statistically.
The study aimed to determine whether bedside ultrasound can be used as a rapid, reliable, and practical method for confirming endotracheal tube placement in emergency department patients.
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
konyaaltı
-
Antalya, konyaaltı, Turkije (Türkiye), 07100
- University of Health Sciences, Antalya Training and Research Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- Patients aged 18 years or older
- Patients who underwent endotracheal intubation in the emergency department as part of routine emergency care
- Patients in whom bedside ultrasound and capnometric end-tidal carbon dioxide assessment were performed for confirmation of endotracheal tube placement
Exclusion Criteria:
- Patients younger than 18 years of age
- Patients with missing or incomplete study data
- Patients with ultrasound images of insufficient quality for evaluation
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
|---|
|
Patients Undergoing Endotracheal Intubation in the Emergency Department
Adult patients who underwent endotracheal intubation in the emergency department were included in this cohort.
Endotracheal intubation was performed as part of routine emergency care.
Bedside ultrasound was performed during or immediately after intubation by trained emergency physicians without interrupting the procedure.
Ultrasound findings were compared with capnometric end-tidal carbon dioxide measurement, which was used as the reference method for confirming endotracheal tube placement.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Diagnostic Accuracy of Bedside Ultrasound for Confirmation of Endotracheal Tube Placement
Tijdsspanne: During or immediately after endotracheal intubation, within a maximum of 20 seconds
|
The diagnostic accuracy of bedside ultrasound for confirming endotracheal tube placement will be evaluated by comparing ultrasound findings with capnometric end-tidal carbon dioxide measurement, which will be used as the reference method.
Diagnostic performance will be assessed using sensitivity, specificity, positive predictive value, negative predictive value, overall accuracy, and agreement with the reference method.
|
During or immediately after endotracheal intubation, within a maximum of 20 seconds
|
Medewerkers en onderzoekers
Onderzoekers
- Hoofdonderzoeker: MURAT DUYAN, ASSOCIATE PROFESSOR, University of Health Sciences, Antalya Training and Research Hospital
- Studie directeur: HALIT EKICI, MEDICAL DOCTOR, University of Health Sciences, Antalya Training and Research Hospital
- Studie directeur: CEMIL KAVALCI, PROFESSOR, University of Health Sciences, Antalya Training and Research Hospital
- Studie directeur: ENGIN DENIZ ARSLAN, ASSOCIATE PROFESSOR, University of Health Sciences, Antalya Training and Research Hospital
- Studie directeur: FEVZI YILMAZ, University of Health Sciences, Antalya Training and Research Hospital
Publicaties en nuttige links
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Andere studie-ID-nummers
- 2025-019
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Beschrijving IPD-plan
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .