Bedside Ultrasound for Confirmation of Endotracheal Tube Placement in the Emergency Department
The Role of Bedside Ultrasound in Confirming Endotracheal Tube Placement in Patients Undergoing Endotracheal Intubation in the Emergency Department
This prospective observational study evaluated the role of bedside ultrasound in confirming endotracheal tube placement in adult patients who underwent endotracheal intubation in the emergency department. Correct placement of the endotracheal tube is critical because unrecognized incorrect placement may cause hypoxemia, hypoxic brain injury, or death.
In this study, bedside ultrasound was performed during or immediately after endotracheal intubation without interfering with the intubation procedure. Ultrasound findings were compared with capnographic end-tidal carbon dioxide measurement, which was used as the reference method for confirming tube placement. The main aim was to assess whether bedside ultrasound is a useful and reliable method for confirming endotracheal tube position in emergency department patients.
Studieöversikt
Status
Detaljerad beskrivning
This single-center, prospective observational diagnostic accuracy study was conducted in the Emergency Department of Antalya Training and Research Hospital. Adult patients who underwent endotracheal intubation in the emergency department after ethics committee approval were included.
Endotracheal intubation was performed as part of routine emergency care by the most senior emergency medicine resident or an experienced emergency physician. Bedside ultrasound assessment was performed during or immediately after intubation by trained emergency physicians without interrupting or delaying the intubation procedure. The ultrasound examination was performed from the suprasternal notch region to assess the position of the endotracheal tube.
The physicians who performed bedside ultrasound had at least two years of emergency medicine experience and had completed accredited ultrasound training. Before study data collection, they received additional theoretical and practical training focused on ultrasound confirmation of endotracheal tube placement.
Ultrasound findings were compared with capnometric end-tidal carbon dioxide measurement, which was used as the reference method for confirmation of endotracheal tube placement. Ultrasound images were stored in the hospital computer system and reviewed by two qualified, independent radiology specialists. Images or measurements with insufficient quality were excluded from analysis. Agreement between ultrasound assessments was evaluated statistically.
The study aimed to determine whether bedside ultrasound can be used as a rapid, reliable, and practical method for confirming endotracheal tube placement in emergency department patients.
Studietyp
Inskrivning (Faktisk)
Kontakter och platser
Studieorter
-
-
konyaaltı
-
Antalya, konyaaltı, Turkiet (Türkiye), 07100
- University of Health Sciences, Antalya Training and Research Hospital
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
- Vuxen
- Äldre vuxen
Tar emot friska volontärer
Testmetod
Studera befolkning
Beskrivning
Inclusion Criteria:
- Patients aged 18 years or older
- Patients who underwent endotracheal intubation in the emergency department as part of routine emergency care
- Patients in whom bedside ultrasound and capnometric end-tidal carbon dioxide assessment were performed for confirmation of endotracheal tube placement
Exclusion Criteria:
- Patients younger than 18 years of age
- Patients with missing or incomplete study data
- Patients with ultrasound images of insufficient quality for evaluation
Studieplan
Hur är studien utformad?
Designdetaljer
Kohorter och interventioner
Grupp / Kohort |
|---|
|
Patients Undergoing Endotracheal Intubation in the Emergency Department
Adult patients who underwent endotracheal intubation in the emergency department were included in this cohort.
Endotracheal intubation was performed as part of routine emergency care.
Bedside ultrasound was performed during or immediately after intubation by trained emergency physicians without interrupting the procedure.
Ultrasound findings were compared with capnometric end-tidal carbon dioxide measurement, which was used as the reference method for confirming endotracheal tube placement.
|
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Diagnostic Accuracy of Bedside Ultrasound for Confirmation of Endotracheal Tube Placement
Tidsram: During or immediately after endotracheal intubation, within a maximum of 20 seconds
|
The diagnostic accuracy of bedside ultrasound for confirming endotracheal tube placement will be evaluated by comparing ultrasound findings with capnometric end-tidal carbon dioxide measurement, which will be used as the reference method.
Diagnostic performance will be assessed using sensitivity, specificity, positive predictive value, negative predictive value, overall accuracy, and agreement with the reference method.
|
During or immediately after endotracheal intubation, within a maximum of 20 seconds
|
Samarbetspartners och utredare
Utredare
- Huvudutredare: MURAT DUYAN, ASSOCIATE PROFESSOR, University of Health Sciences, Antalya Training and Research Hospital
- Studierektor: HALIT EKICI, MEDICAL DOCTOR, University of Health Sciences, Antalya Training and Research Hospital
- Studierektor: CEMIL KAVALCI, PROFESSOR, University of Health Sciences, Antalya Training and Research Hospital
- Studierektor: ENGIN DENIZ ARSLAN, ASSOCIATE PROFESSOR, University of Health Sciences, Antalya Training and Research Hospital
- Studierektor: FEVZI YILMAZ, University of Health Sciences, Antalya Training and Research Hospital
Publikationer och användbara länkar
Studieavstämningsdatum
Studera stora datum
Studiestart (Faktisk)
Primärt slutförande (Faktisk)
Avslutad studie (Faktisk)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Faktisk)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Nyckelord
Andra studie-ID-nummer
- 2025-019
Plan för individuella deltagardata (IPD)
Planerar du att dela individuella deltagardata (IPD)?
IPD-planbeskrivning
Läkemedels- och apparatinformation, studiedokument
Studerar en amerikansk FDA-reglerad läkemedelsprodukt
Studerar en amerikansk FDA-reglerad produktprodukt
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .