- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT07669259
Bedside Ultrasound for Confirmation of Endotracheal Tube Placement in the Emergency Department
The Role of Bedside Ultrasound in Confirming Endotracheal Tube Placement in Patients Undergoing Endotracheal Intubation in the Emergency Department
This prospective observational study evaluated the role of bedside ultrasound in confirming endotracheal tube placement in adult patients who underwent endotracheal intubation in the emergency department. Correct placement of the endotracheal tube is critical because unrecognized incorrect placement may cause hypoxemia, hypoxic brain injury, or death.
In this study, bedside ultrasound was performed during or immediately after endotracheal intubation without interfering with the intubation procedure. Ultrasound findings were compared with capnographic end-tidal carbon dioxide measurement, which was used as the reference method for confirming tube placement. The main aim was to assess whether bedside ultrasound is a useful and reliable method for confirming endotracheal tube position in emergency department patients.
Přehled studie
Postavení
Detailní popis
This single-center, prospective observational diagnostic accuracy study was conducted in the Emergency Department of Antalya Training and Research Hospital. Adult patients who underwent endotracheal intubation in the emergency department after ethics committee approval were included.
Endotracheal intubation was performed as part of routine emergency care by the most senior emergency medicine resident or an experienced emergency physician. Bedside ultrasound assessment was performed during or immediately after intubation by trained emergency physicians without interrupting or delaying the intubation procedure. The ultrasound examination was performed from the suprasternal notch region to assess the position of the endotracheal tube.
The physicians who performed bedside ultrasound had at least two years of emergency medicine experience and had completed accredited ultrasound training. Before study data collection, they received additional theoretical and practical training focused on ultrasound confirmation of endotracheal tube placement.
Ultrasound findings were compared with capnometric end-tidal carbon dioxide measurement, which was used as the reference method for confirmation of endotracheal tube placement. Ultrasound images were stored in the hospital computer system and reviewed by two qualified, independent radiology specialists. Images or measurements with insufficient quality were excluded from analysis. Agreement between ultrasound assessments was evaluated statistically.
The study aimed to determine whether bedside ultrasound can be used as a rapid, reliable, and practical method for confirming endotracheal tube placement in emergency department patients.
Typ studie
Zápis (Aktuální)
Kontakty a umístění
Studijní místa
-
-
konyaaltı
-
Antalya, konyaaltı, Turecko (Türkiye), 07100
- University of Health Sciences, Antalya Training and Research Hospital
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Metoda odběru vzorků
Studijní populace
Popis
Inclusion Criteria:
- Patients aged 18 years or older
- Patients who underwent endotracheal intubation in the emergency department as part of routine emergency care
- Patients in whom bedside ultrasound and capnometric end-tidal carbon dioxide assessment were performed for confirmation of endotracheal tube placement
Exclusion Criteria:
- Patients younger than 18 years of age
- Patients with missing or incomplete study data
- Patients with ultrasound images of insufficient quality for evaluation
Studijní plán
Jak je studie koncipována?
Detaily designu
Kohorty a intervence
Skupina / kohorta |
|---|
|
Patients Undergoing Endotracheal Intubation in the Emergency Department
Adult patients who underwent endotracheal intubation in the emergency department were included in this cohort.
Endotracheal intubation was performed as part of routine emergency care.
Bedside ultrasound was performed during or immediately after intubation by trained emergency physicians without interrupting the procedure.
Ultrasound findings were compared with capnometric end-tidal carbon dioxide measurement, which was used as the reference method for confirming endotracheal tube placement.
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Diagnostic Accuracy of Bedside Ultrasound for Confirmation of Endotracheal Tube Placement
Časové okno: During or immediately after endotracheal intubation, within a maximum of 20 seconds
|
The diagnostic accuracy of bedside ultrasound for confirming endotracheal tube placement will be evaluated by comparing ultrasound findings with capnometric end-tidal carbon dioxide measurement, which will be used as the reference method.
Diagnostic performance will be assessed using sensitivity, specificity, positive predictive value, negative predictive value, overall accuracy, and agreement with the reference method.
|
During or immediately after endotracheal intubation, within a maximum of 20 seconds
|
Spolupracovníci a vyšetřovatelé
Vyšetřovatelé
- Vrchní vyšetřovatel: MURAT DUYAN, ASSOCIATE PROFESSOR, University of Health Sciences, Antalya Training and Research Hospital
- Ředitel studie: HALIT EKICI, MEDICAL DOCTOR, University of Health Sciences, Antalya Training and Research Hospital
- Ředitel studie: CEMIL KAVALCI, PROFESSOR, University of Health Sciences, Antalya Training and Research Hospital
- Ředitel studie: ENGIN DENIZ ARSLAN, ASSOCIATE PROFESSOR, University of Health Sciences, Antalya Training and Research Hospital
- Ředitel studie: FEVZI YILMAZ, University of Health Sciences, Antalya Training and Research Hospital
Publikace a užitečné odkazy
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Primární dokončení (Aktuální)
Dokončení studie (Aktuální)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další identifikační čísla studie
- 2025-019
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Popis plánu IPD
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .