Serum ferritin as an indicator of iron status: what do we need to know?

Jahnavi Daru, Katherine Colman, Simon J Stanworth, Barbara De La Salle, Erica M Wood, Sant-Rayn Pasricha, Jahnavi Daru, Katherine Colman, Simon J Stanworth, Barbara De La Salle, Erica M Wood, Sant-Rayn Pasricha

Abstract

Determination of iron status in pregnancy and in young children is essential for both clinical and public health practice. Clinical diagnosis of iron deficiency (ID) through sampling of bone marrow to identify the absence of body iron stores is impractical in most cases. Serum ferritin (SF) concentrations are the most commonly deployed indicator for determining ID, and low SF concentrations reflect a state of iron depletion. However, there is considerable variation in SF cutoffs recommended by different expert groups to diagnose ID. Moreover, the cutoffs used in different clinical laboratories are heterogeneous. There are few studies of diagnostic test accuracy to establish the sensitivity and specificity of SF compared with key gold standards (such as absent bone marrow iron stores, increased intestinal iron absorption, and hemoglobin response to SF) among noninflamed, outpatient populations. The limited data available suggest the commonly recommended SF cutoff of <15 μg/L is a specific but not sensitive cutoff, although evidence is limited. Data from women during pregnancy or from young children are especially uncommon. Most data are from studies conducted >30 y ago, do not reflect ethnic or geographic diversity, and were performed in an era for which laboratory methods no longer reflect present practice. Future studies to define the appropriate SF cutoffs are urgently needed and would also provide an opportunity to compare this indicator with other established and emerging iron indexes. In addition, future work would benefit from a focus on elucidating cutoffs and indexes relevant to iron adequacy.

Keywords: cutoffs; diagnostic test; ferritin; hepcidin; iron deficiency; iron deficiency anemia; iron status.

© 2017 American Society for Nutrition.

Figures

FIGURE 1
FIGURE 1
Analysis of diagnostic test accuracy. Example of a receiver operating characteristic curve; a higher AUCROC indicates a superior test for identifying the corresponding gold standard. AUCROC, area under the receiver operating characteristic curve.
FIGURE 2
FIGURE 2
Distribution of the lower limit of the SF range in laboratories served by the UK NEQAS. In 2016 we contacted 606 laboratories predominantly in the United Kingdom and the rest of Europe participating in the UK NEQAS program and received data from 208. Laboratories were asked to provide information on the lower limit of the SF concentration as included with their results. Data on SF cutoffs used in each population category were collected. Each dot represents a laboratory reporting a specific SF cutoff in the defined population subgroup (K Coleman, E Wood, B De La Salle, S Stanworth, and S-R Pasricha, unpublished results, 2016). SF, serum ferritin; UK NEQAS, United Kingdom National External Quality Assessment Service.

Source: PubMed