Hand-Held Ultrasound Devices Compared with High-End Ultrasound Systems: A Systematic Review

Alexander Rykkje, Jonathan Frederik Carlsen, Michael Bachmann Nielsen, Alexander Rykkje, Jonathan Frederik Carlsen, Michael Bachmann Nielsen

Abstract

The aim of this study was to review the scientific literature available on the comparison of hand-held ultrasound devices with high-end systems for abdominal and pleural applications. PubMed, Embase, Web of Science and Cochrane were searched following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Original research describing hand-held ultrasound devices compared with high-end systems was included and assessed using Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2. The search was limited to articles published since 1 January 2012. A total of 2486 articles were found and screened by title and abstract. A total of 16 articles were chosen for final review. All of the included articles showed good overall agreement between hand-held and high-end ultrasound systems. Strong correlations were found when evaluating ascites, hydronephrosis, pleural cavities, in detection of abdominal aortic aneurysms and for use with obstetric and gynaecological patients. Other articles found good agreement for cholelithiasis and for determining the best site for paracentesis. QUADAS-2 analysis suggested few risks of bias and almost no concerns regarding applicability. For distinct clinical questions, hand-held devices may be a valuable supplement to physical examination. However, evidence is inadequate, and more research is needed on the abdominal and pleural use of hand-held ultrasound with more standardised comparisons, using only blinded reviewers.

Keywords: abdomen; comparison; hand-held; pleura; pocket devices; portable; ultrasound.

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure 1
Figure 1
Flow chart following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. * Of the 88 articles excluded, 47 were conference abstracts or letters, 19 did not compare with a high-end ultrasound system, 9 did not use a true hand-held ultrasound device, 8 were not related to abdominal or pleural applications, three were not in English and two were conducted on animals.

References

    1. Tse K.H., Luk W.H., Lam M.C. Pocket-sized versus standard ultrasound machines in abdominal imaging. Singap. Med. J. 2014;55:325–333. doi: 10.11622/smedj.2014078.
    1. Piscaglia F., Dietrich C., Nolsøe C. Birth of “Echoscopy”—The EFSUMB Point of View. Ultraschall Med.—Eur. J. Ultrasound. 2013;34:92. doi: 10.1055/s-0032-1319207.
    1. Hand-Held Ultrasound Systems—All Medical Device Manufacturers. [(accessed on 18 April 2019)]; Available online: .
    1. Colli A., Prati D., Fraquelli M., Segato S., Vescovi P.P., Colombo F., Balduini C., Della Valle S., Casazza G. The use of a pocket-sized ultrasound device improves physical examination: Results of an in- and outpatient cohort study. PLoS ONE. 2015;10:e0122181. doi: 10.1371/journal.pone.0122181.
    1. Cardim N., Fernandez Golfin C., Ferreira D., Aubele A., Toste J., Angel Cobos M., Carmelo V., Nunes I., Oliveira A.G., Zamorano J. Usefulness of a New Miniaturized Echocardiographic System in Outpatient Cardiology Consultations as an Extension of Physical Examination. J. Am. Soc. Echocardiogr. 2011;24:117–124. doi: 10.1016/j.echo.2010.09.017.
    1. Mancuso F.J.N., Siqueira V.N., Moisés V.A., Gois A.F.T., de Paola A.A.V., Carvalho A.C.C., Campos O. Focused cardiac ultrasound using a pocket-size device in the emergency room. Arq. Bras. Cardiol. 2014;103:530–537. doi: 10.5935/abc.20140158.
    1. Neesse A., Jerrentrup A., Hoffmann S., Sattler A., Görg C., Kill C., Gress T.M., Kunsch S. Prehospital chest emergency sonography trial in Germany: A prospective study. Eur. J. Emerg. Med. Off. J. Eur. Soc. Emerg. Med. 2012;19:161–166. doi: 10.1097/MEJ.0b013e328349edcc.
    1. Andersen G.N., Viset A., Mjølstad O.C., Salvesen O., Dalen H., Haugen B.O. Feasibility and accuracy of point-of-care pocket-size ultrasonography performed by medical students. BMC Med. Educ. 2014;14:156. doi: 10.1186/1472-6920-14-156.
    1. Nguyen A.T.V., Hill G.B., Versteeg M.P.T., Thomson I.A., van Rij A.M. Novices may be trained to screen for abdominal aortic aneurysms using ultrasound. Cardiovasc. Ultrasound. 2013;11:42. doi: 10.1186/1476-7120-11-42.
    1. Moher D., Liberati A., Tetzlaff J., Altman D.G., PRISMA Group Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement. Ann. Intern. Med. 2009;151:264–269. doi: 10.7326/0003-4819-151-4-200908180-00135.
    1. Whiting P.F., Rutjes A.W.S., Westwood M.E., Mallett S., Deeks J.J., Reitsma J.B., Leeflang M.M.G., Sterne J.A.C., Bossuyt P.M.M., QUADAS-2 Group QUADAS-2: A revised tool for the quality assessment of diagnostic accuracy studies. Ann. Intern. Med. 2011;155:529–536. doi: 10.7326/0003-4819-155-8-201110180-00009.
    1. Dalen H., Gundersen G.H., Skjetne K., Haug H.H., Kleinau J.O., Norekval T.M., Graven T. Feasibility and reliability of pocket-size ultrasound examinations of the pleural cavities and vena cava inferior performed by nurses in an outpatient heart failure clinic. Eur. J. Cardiovasc. Nurs. J. Work. Group Cardiovasc. Nurs. Eur. Soc. Cardiol. 2015;14:286–293. doi: 10.1177/1474515114547651.
    1. Graven T., Wahba A., Hammer A.M., Sagen O., Olsen Ø., Skjetne K., Kleinau J.O., Dalen H. Focused ultrasound of the pleural cavities and the pericardium by nurses after cardiac surgery. Scand. Cardiovasc. J. 2015;49:56–63. doi: 10.3109/14017431.2015.1009383.
    1. Del Medico M., Altieri A., Carnevale-Maffè G., Formagnana P., Casella F., Barchiesi M., Bergonzi M., Vattiato C., Casazza G., Cogliati C. Pocket-size ultrasound device in cholelithiasis: Diagnostic accuracy and efficacy of short-term training. Intern. Emerg. Med. 2018;13:1121–1126. doi: 10.1007/s11739-018-1901-3.
    1. Andrea S., Giovanna L., Pietro C., Luca F. Teaching echoscopy for the early diagnosis of ascites in cirrhosis: Assessment of an objective structured clinical examination (OSCE) J. Ultrasound. 2017;20:123–126. doi: 10.1007/s40477-017-0250-9.
    1. Stock K.F., Klein B., Steubl D., Lersch C., Heemann U., Wagenpfeil S., Eyer F., Clevert D.-A. Comparison of a pocket-size ultrasound device with a premium ultrasound machine: Diagnostic value and time required in bedside ultrasound examination. Abdom. Imaging. 2015;40:2861–2866. doi: 10.1007/s00261-015-0406-z.
    1. Barreiros A.P., Cui X.W., Ignee A., De Molo C., Pirri C., Dietrich C.F. EchoScopy in scanning abdominal diseases: Initial clinical experience. Z. Gastroenterol. 2014;52:269–275. doi: 10.1055/s-0033-1350114.
    1. Coşkun F., Akıncı E., Ceyhan M.A., Sahin Kavaklı H. Our new stethoscope in the emergency department: Handheld ultrasound. Ulusal Travma Ve Acil Cerrahi Dergisi = Turk. J. Trauma Emerg. Surg. 2011;17:488–492.
    1. Kameda T., Uebayashi K., Wagai K., Kawai F., Taniguchi N. Assessment of the renal collecting system using a pocket-sized ultrasound device. J. Med. Ultrason. 2001. 2018;45:577–581. doi: 10.1007/s10396-018-0881-2.
    1. Lavi A., Tzemah S., Hussein A., Bishara I., Shcherbakov N., Zelichenko G., Mashiah A., Gross M., Cherbinski L., Neeman Z., et al. A urologic stethoscope? Urologist performed sonography using a pocket-size ultrasound device in the point-of-care setting. Int. Urol. Nephrol. 2017;49:1513–1518. doi: 10.1007/s11255-017-1641-8.
    1. Bruns R.F., Menegatti C.M., Martins W.P., Araujo Júnior E. Applicability of pocket ultrasound during the first trimester of pregnancy. Med. Ultrason. 2015;17:284–288. doi: 10.11152/mu.2013.2066.173.rfb.
    1. Galjaard S., Baeck S., Ameye L., Bourne T., Timmerman D., Devlieger R. Use of a pocket-sized ultrasound machine (PUM) for routine examinations in the third trimester of pregnancy. Ultrasound Obstet. Gynecol. Off. J. Int. Soc. Ultrasound Obstet. Gynecol. 2014;44:64–68. doi: 10.1002/uog.13285.
    1. Troyano Luque J.M., Ferrer-Roca O., Barco-Marcellán M.J., Sabatel López R., Pérez-Medina T., Pérez-Lopez F.R. Modification of the hand-held Vscan ultrasound and verification of its performance for transvaginal applications. Ultrasonics. 2013;53:17–22. doi: 10.1016/j.ultras.2012.03.006.
    1. Sayasneh A., Preisler J., Smith A., Saso S., Naji O., Abdallah Y., Stalder C., Daemen A., Timmerman D., Bourne T. Do pocket-sized ultrasound machines have the potential to be used as a tool to triage patients in obstetrics and gynecology? Ultrasound Obstet. Gynecol. Off. J. Int. Soc. Ultrasound Obstet. Gynecol. 2012;40:145–150. doi: 10.1002/uog.11184.
    1. Esposito R., Ilardi F., Schiano Lomoriello V., Sorrentino R., Sellitto V., Giugliano G., Esposito G., Trimarco B., Galderisi M. Identification of the main determinants of abdominal aorta size: A screening by Pocket Size Imaging Device. Cardiovasc. Ultrasound. 2017;15:2. doi: 10.1186/s12947-016-0094-z.
    1. Bonnafy T., Lacroix P., Desormais I., Labrunie A., Marin B., Leclerc A., Oueslati A., Rollé F., Vignon P., Aboyans V. Reliability of the measurement of the abdominal aortic diameter by novice operators using a pocket-sized ultrasound system. Arch. Cardiovasc. Dis. 2013;106:644–650. doi: 10.1016/j.acvd.2013.08.004.
    1. Dijos M., Pucheux Y., Lafitte M., Réant P., Prevot A., Mignot A., Barandon L., Roques X., Roudaut R., Pilois X., et al. Fast track echo of abdominal aortic aneurysm using a real pocket-ultrasound device at bedside. Echocardiography (Mount Kisco, NY) 2012;29:285–290. doi: 10.1111/j.1540-8175.2011.01559.x.
    1. Nielsen M.B., Cantisani V., Sidhu P.S., Badea R., Batko T., Carlsen J., Claudon M., Ewertsen C., Garre C., Genov J., et al. The Use of Handheld Ultrasound Devices—An EFSUMB Position Paper. Ultraschall Med. Stuttg. Ger. 1980. 2019;40:30–39.
    1. Mjolstad O.C., Dalen H., Graven T., Kleinau J.O., Salvesen O., Haugen B.O. Routinely adding ultrasound examinations by pocket-sized ultrasound devices improves inpatient diagnostics in a medical department. Eur. J. Intern. Med. 2012;23:185–191. doi: 10.1016/j.ejim.2011.10.009.
    1. Andersen G.N., Graven T., Skjetne K., Mjølstad O.C., Kleinau J.O., Olsen Ø., Haugen B.O., Dalen H. Diagnostic influence of routine point-of-care pocket-size ultrasound examinations performed by medical residents. J. Ultrasound Med. Off. J. Am. Inst. Ultrasound Med. 2015;34:627–636. doi: 10.7863/ultra.34.4.627.
    1. Kjesbu I.E., Laursen C.B., Graven T., Holden H.M., Rømo B., Newton Andersen G., Mjølstad O.C., Lassen A., Dalen H. Feasibility and Diagnostic Accuracy of Point-of-Care Abdominal Sonography by Pocket-Sized Imaging Devices, Performed by Medical Residents. J. Ultrasound Med. Off. J. Am. Inst. Ultrasound Med. 2017;36:1195–1202. doi: 10.7863/ultra.16.05077.
    1. Becker D.M., Tafoya C.A., Becker S.L., Kruger G.H., Tafoya M.J., Becker T.K. The use of portable ultrasound devices in low- and middle-income countries: A systematic review of the literature. Trop. Med. Int. Health. 2016;21:294–311. doi: 10.1111/tmi.12657.
    1. Filipiak-Strzecka D., Michalski B., Kasprzak J.D., Lipiec P. Pocket-size imaging devices allow for reliable bedside screening for femoral artery access site complications. Ultrasound Med. Biol. 2014;40:2753–2758. doi: 10.1016/j.ultrasmedbio.2014.06.022.
    1. Vscan with Dual Probe—DATA Sheet. [(accessed on 8 June 2019)]; Available online: .
    1. Acuson P10 Hand Held Ultrasound. [(accessed on 8 June 2019)]; Available online: .
    1. Galusko V., Bodger O., Ionescu A. A systematic review of pocket-sized imaging devices: Small and mighty? Echo Res. Pract. 2018;5:113–138. doi: 10.1530/ERP-18-0030.
    1. Platz E., Pivetta E., Merz A.A., Peck J., Rivero J., Cheng S. Impact of device selection and clip duration on lung ultrasound assessment in patients with heart failure. Am. J. Emerg. Med. 2015;33:1552–1556. doi: 10.1016/j.ajem.2015.06.002.
    1. Gursel G., Inci K., Alasgarova Z. Can Diaphragm Dysfunction Be Reliably Evaluated with Pocket-Sized Ultrasound Devices in Intensive Care Unit? Crit. Care Res. Pract. 2018:5192647. doi: 10.1155/2018/5192647.
    1. Sisó-Almirall A., Kostov B., Navarro González M., Cararach Salami D., Pérez Jiménez A., Gilabert Solé R., Bru Saumell C., Donoso Bach L., Villalta Martí M., González-de Paz L., et al. Abdominal aortic aneurysm screening program using hand-held ultrasound in primary healthcare. PLoS ONE. 2017;12:e0176877. doi: 10.1371/journal.pone.0176877.
    1. Ojeda J.C., Colbert J.A., Lin X., McMahon G.T., Doubilet P.M., Benson C.B., Wu J., Katz J.T., Yialamas M.A. Pocket-sized ultrasound as an aid to physical diagnosis for internal medicine residents: A randomized trial. J. Gen. Intern. Med. 2015;30:199–206. doi: 10.1007/s11606-014-3086-4.
    1. Keil-Ríos D., Terrazas-Solís H., González-Garay A., Sánchez-Ávila J.F., García-Juárez I. Pocket ultrasound device as a complement to physical examination for ascites evaluation and guided paracentesis. Intern. Emerg. Med. 2016;11:461–466. doi: 10.1007/s11739-016-1406-x.
    1. Thuemmler C., Paulin A., Jell T., Lim A.K. Information technology—Next generation: The impact of 5G on the evolution of health and care services. In: Latifi S., editor. Information Technology—New Generations. Springer; Cham, Switzerland: 2018. pp. 811–817.
    1. Brattain L.J., Telfer B.A., Dhyani M., Grajo J.R., Samir A.E. Machine learning for medical ultrasound: Status, methods, and future opportunities. Abdom. Radiol. (NY) 2018;43:786–799. doi: 10.1007/s00261-018-1517-0.

Source: PubMed

3
订阅