Assessment of fluid responsiveness during increased intra-abdominal pressure: keep the indices, but change the thresholds

Benoit Tavernier, Emmanuel Robin, Benoit Tavernier, Emmanuel Robin

Abstract

Dynamic variables of fluid responsiveness are useful guides for fluid management in patients under controlled positive pressure ventilation. In the previous issue of Critical Care, Jacques and colleagues show that these variables remain reliable predictors of fluid responsiveness in a porcine model of intra-abdominal hypertension, but threshold values are higher than during normal intra-abdominal pressure. Their threshold values, however, cannot be applied to clinical practice. This study suggests that intra-abdominal pressure must be measured in critically ill patients, and 'supranormal' values of dynamic variables should be analyzed with caution. The 'fluid responsive part' of an increased dynamic variable in such patients may be estimated by measuring its change during a fluid challenge.

References

    1. Jacques D, Bendjelid K, Duperret S, Colling J, Piriou V, Viale JP. Pulse pressure variation and stroke volume variation during increased intra-abdominal pressure: an experimental study. Crit Care. 2011;15:R33. doi: 10.1186/cc9980.
    1. Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature. Crit Care Med. 2009;37:2642–2647. doi: 10.1097/CCM.0b013e3181a590da.
    1. Szold A, Pizov R, Segal E, Perel A. The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs. Intensive Care Med. 1989;15:368–371. doi: 10.1007/BF00261495.
    1. Biais M, Bernard O, Ha JC, Degryse C, Sztark F. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. Br J Anaesth. 2010;104:407–413. doi: 10.1093/bja/aeq031.
    1. Malbrain M. Abdominal compartment syndrome. F1000 Med Rep. 2009;1:86.
    1. Malbrain ML, De Laet I. Functional hemodynamics and increased intra-abdominal pressure: Same thresholds for different conditions...? Crit Care Med. 2009;37:781–783. doi: 10.1097/CCM.0b013e318194c397.
    1. Mahjoub Y, Touzeau J, Airapetian N, Lorne E, Hijazi M, Zogheib E, Tinturier F, Slama M, Dupont H. The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension. Crit Care Med. 2010;38:1824–1829. doi: 10.1097/CCM.0b013e3181eb3c21.
    1. Renner J, Gruenewald M, Quaden R, Hanss R, Meybohm P, Steinfath M, Scholz J, Bein B. Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model. Crit Care Med. 2009;37:650–658. doi: 10.1097/CCM.0b013e3181959864.

Source: PubMed

3
订阅