Electromagnetic navigation bronchoscopic dye marking for localization of small subsolid nodules: Retrospective observational study

Kwanyong Hyun, In Kyu Park, Jae Won Song, Samina Park, Chang Hyun Kang, Young Tae Kim, Kwanyong Hyun, In Kyu Park, Jae Won Song, Samina Park, Chang Hyun Kang, Young Tae Kim

Abstract

Thoracoscopic resection of small subsolid nodules is challenging and requires preoperative localization. We investigated the efficacy, safety, and factors affecting accuracy in localizing pulmonary nodules with electromagnetic navigation bronchoscopy (ENB)-guided dye marking.Patients with small subsolid nodule(s) who underwent thoracoscopic resection after ENB-guided dye marking were retrospectively reviewed. Dye marking was performed at the nearest pleura and the localized nodule(s) was resected thoracoscopically. Efficacy was evaluated by success rates of dye marking and resection of nodules. Navigation accuracy was represented by target distance, which was the closest distance between target and the tip of locatable guide. Factors affecting target distance were evaluated by linear regression analyses.Twenty-nine ENB-guided dye markings were done for 24 nodules in 20 patients. The success rate of the dye marking and nodule localization were 93.1% (27/29) and 95.8% (23/24), respectively. Twenty-three nodules were completely resected thoracoscopically without conversion. There were no ENB-related complications: pneumothorax or bronchopulmonary hemorrhage. Nine targets were in the upper, 14 in the middle, and 6 in the lower zone. Even though navigation time was longer in the upper zone, target distance showed no significant inter-zone difference. Approach angle was the only significant predictor for target distance (0-45°, estimate = -1.24, P = .01; 45-90°, estimate = -1.26, P = .006; reference = ≥90°).Localization with ENB-guided dye marking is effective and safe for thoracoscopic resection of small subsolid nodules. For better performance, a pathway with smaller approach angle (<90°) should be selected to increase the navigation accuracy.

Conflict of interest statement

The authors have no funding and no conflicts of interest to disclose.

Figures

Figure 1
Figure 1
Illustrations for navigation parameters. (A) Approach angle and (B) tunneling distance from the bronchiole exit point, and (C) target distance from navigation tip to the target.
Figure 2
Figure 2
(A) Computed tomography images of nondominant subsolid nodule in the left upper lobe (white arrow) and dominant nodule in the left lower lobe (yellow arrow). (B) Planning map showing 2 marking targets for the nodule in the left upper lobe (green balls).
Figure 3
Figure 3
Flow diagram of surgery for 24 subsolid nodules. ADC = adenocarcinoma, MIA = minimally invasive adenocarcinoma, AIS = adenocarcinoma in situ, AAH = atypical adenomatous hyperplasia.

References

    1. Henschke CI, Yankelevitz DF, Mirtcheva R, et al. CT screening for lung cancer: frequency and significance of part-solid and nonsolid nodules. AJR Am J Roentgenol 2002;178:1053–7.
    1. Aberle DR, Adams AM, et al. National Lung Screening Trial Research T. Reduced lung-cancer mortality with low-dose computed tomographic screening. N Engl J Med 2011;365:395–409.
    1. MacMahon H, Naidich DP, Goo JM, et al. Guidelines for management of incidental pulmonary nodules detected on CT images: from the Fleischner Society 2017. Radiology 2017;284:228–43.
    1. Zaman M, Bilal H, Woo CY, et al. In patients undergoing video-assisted thoracoscopic surgery excision, what is the best way to locate a subcentimetre solitary pulmonary nodule in order to achieve successful excision? Interact Cardiovasc Thorac Surg 2012;15:266–72.
    1. Schwarz Y, Greif J, Becker HD, et al. Real-time electromagnetic navigation bronchoscopy to peripheral lung lesions using overlaid CT images: the first human study. Chest 2006;129:988–94.
    1. Marino KA, Sullivan JL, Weksler B. Electromagnetic navigation bronchoscopy for identifying lung nodules for thoracoscopic resection. Ann Thorac Surg 2016;102:454–7.
    1. Awais O, Reidy MR, Mehta K, et al. Electromagnetic navigation bronchoscopy-guided dye marking for thoracoscopic resection of pulmonary nodules. Ann Thorac Surg 2016;102:223–9.
    1. Luo K, Lin Y, Lin X, et al. Localization of peripheral pulmonary lesions to aid surgical resection: a novel approach for electromagnetic navigation bronchoscopic dye marking. Eur J Cardiothorac Surg 2017;52:516–21.
    1. Naidich DP, Bankier AA, MacMahon H, et al. Recommendations for the management of subsolid pulmonary nodules detected at CT: a statement from the Fleischner Society. Radiology 2013;266:304–17.
    1. Finley DJ, Yoshizawa A, Travis W, et al. Predictors of outcomes after surgical treatment of synchronous primary lung cancers. J Thorac Oncol 2010;5:197–205.
    1. Vazquez M, Carter D, Brambilla E, et al. Solitary and multiple resected adenocarcinomas after CT screening for lung cancer: histopathologic features and their prognostic implications. Lung Cancer 2009;64:148–54.
    1. Kohno T, Fujimori S, Kishi K, et al. Safe and effective minimally invasive approaches for small ground glass opacity. Ann Thorac Surg 2010;89:S2114–7.
    1. Mun M, Kohno T. Efficacy of thoracoscopic resection for multifocal bronchioloalveolar carcinoma showing pure ground-glass opacities of 20 mm or less in diameter. J Thorac Cardiovasc Surg 2007;134:877–82.
    1. Sortini D, Feo C, Maravegias K, et al. Intrathoracoscopic localization techniques. Review of literature. Surg Endosc 2006;20:1341–7.
    1. Khereba M, Ferraro P, Duranceau A, et al. Thoracoscopic localization of intraparenchymal pulmonary nodules using direct intracavitary thoracoscopic ultrasonography prevents conversion of VATS procedures to thoracotomy in selected patients. J Thorac Cardiovasc Surg 2012;144:1160–5.
    1. Chen S, Zhou J, Zhang J, et al. Video-assisted thoracoscopic solitary pulmonary nodule resection after CT-guided hookwire localization: 43 cases report and literature review. Surg Endosc 2011;25:1723–9.
    1. Khandhar SJ, Bowling MR, Flandes J, et al. Electromagnetic navigation bronchoscopy to access lung lesions in 1,000 subjects: first results of the prospective, multicenter NAVIGATE study. BMC Pulm Med 2017;17:59.
    1. Seijo LM, de Torres JP, Lozano MD, et al. Diagnostic yield of electromagnetic navigation bronchoscopy is highly dependent on the presence of a Bronchus sign on CT imaging: results from a prospective study. Chest 2010;138:1316–21.
    1. Eberhardt R, Morgan RK, Ernst A, et al. Comparison of suction catheter versus forceps biopsy for sampling of solitary pulmonary nodules guided by electromagnetic navigational bronchoscopy. Respiration 2010;79:54–60.
    1. Gex G, Pralong JA, Combescure C, et al. Diagnostic yield and safety of electromagnetic navigation bronchoscopy for lung nodules: a systematic review and meta-analysis. Respiration 2014;87:165–76.
    1. Bolton WD, Cochran T, Ben-Or S, et al. Electromagnetic navigational bronchoscopy reduces the time required for localization and resection of lung nodules. Innovations (Phila) 2017;12:333–7.
    1. Brown J, Lee TJ, Joiner T, et al. Using electromagnetic navigation bronchoscopy and dye injection to aid in video-assisted lung resection. Am Surg 2016;82:1052–4.
    1. Herth FJ, Eberhardt R, Sterman D, et al. Bronchoscopic transparenchymal nodule access (BTPNA): first in human trial of a novel procedure for sampling solitary pulmonary nodules. Thorax 2015;70:326–32.
    1. Bolton WD, Howe H, 3rd, Stephenson JE. The utility of electromagnetic navigational bronchoscopy as a localization tool for robotic resection of small pulmonary nodules. Ann Thorac Surg 2014;98:471–5. discussion 475-476.
    1. Chen A, Pastis N, Furukawa B, et al. The effect of respiratory motion on pulmonary nodule location during electromagnetic navigation bronchoscopy. Chest 2015;147:1275–81.
    1. Jain P, Fleming P, Mehta AC. Radiation safety for health care workers in the bronchoscopy suite. Clin Chest Med 1999;20:33–8. ix-x.
    1. Bansal S, Hale K, Sethi S, et al. Electromagnetic navigational bronchoscopy: a learning curve analysis. Chest 2007;132:514B.
    1. Port J, Harrison S. Electromagnetic navigational bronchoscopy. Semin Intervent Radiol 2013;30:128–32.

Source: PubMed