Investigation to Evaluate Performance and Safety of RemovAid ™ in Removal of Contraceptive Implants (REVALID03)
A Prospective, Single-centre, Non-comparative Feasibility Investigation to Evaluate Performance and Safety of RemovAid ™ Retrieval Device When Used for Removal of Palpable Subdermal Contraceptive Rod Implants
The safety and efficacy of a subdermal implant retrieval device (RemovAid) is investigated in a population of 25 women seeking removal of their palpable contraceptive implants.
The primary endpoint of the device is to evaluate the performance of the device, specifically its success rate in removing palpable contraceptive implants. The device shall be able to fixate at least 80% of palpable implants, and successfully remove at least 90% of these implants.
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
Similar to the REVALID and REVALID02 investigations, the REVALID03 investigation aims to recruit a total of 25 women with a palpable contraceptive implant due for removal, in order to obtain at least 20 successful fixations.
The implant retrieval device aims to standardize and simplify the implant removal procedure. There is no comparator in the investigation. Descriptive data will be recorded, all recruited subjects will be exposed to the investigational medical device (IMD) The primary endpoint is the percentage of fixated implants that are successfully removed without the use of additional tools.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Stockholm, Sweden, 17176
- Karolinska University Hospital
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Female age 18 or older
- Willing to remove a palpable subdermal Implanon/ Nexplanon CI
- Willing and able to give written informed consent for participation in the investigation
- Willing to provide follow-up information according to the Clinical Investigators brochure
Exclusion Criteria:
- Known allergy to local anaesthetic (lidocaine/lignocaine) or disinfectant (chlorhexidine).
- Active skin lesion over the CI.
- The Investigator considers the subject unlikely to comply with investigational procedures, restrictions and requirements.
- Any contraindication for removal of the PI, as judged by the Investigator.
- Any disorders or medications that might affect coagulation, as judged by the Investigator.
- Any conditions suspected to affect healing or increase risk of infection (e.g. keloid tendency, diabetes or any upper arm dermatological condition that may affect upper arm healing)
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Supportive Care
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: RemovAid arm
RemovAid arm - All subjects have their implant removed by the RemovAid device |
The RemovAid device is used for removal
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Successful removal of implant
Time Frame: 15 minutes
|
The percentage of fixated implants that are successfully removed by the device without the use of additional tools
|
15 minutes
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Frequency, severity, causality and outcome of adverse events (AEs)
Time Frame: 1 week
|
Both Anticipated and unanticipated AEs will be recorded, both immediately following the intervention and at follow-up
|
1 week
|
|
Pain during procedure: Visual Analogue Scale
Time Frame: 15 minutes
|
Mean pain score (maximum pain intensity during the procedure) indicated by the subject on a Visual Analogue Scale 0-100 mm ruler, assuming that anaesthesia has been properly administered.
Higher values represent a worse outcome.
|
15 minutes
|
|
Success of fixation of implant
Time Frame: 5 minutes
|
Percentage of palpable implants where the implant could be seen and/or felt on both sides of the clamp after maximum three attempts of fixation.
80% or more is considered success.
|
5 minutes
|
|
Duration of procedure
Time Frame: 25 minutes
|
Mean time from making incision until implant is removed, and first touching subject with the device until implant extracted
|
25 minutes
|
|
Technical functionality of device determined by an operators questionnaire
Time Frame: 5 minutes
|
Fulfilment of pre-defined technical requirements, as documented on an operator functionality questionnaire.
The questionnaire consists of a range of yes/no questions to device functionality
|
5 minutes
|
|
Operators impression of the device
Time Frame: 5 minutes
|
The operator's global impression of the IMD will be assessed using a scale 1-5, where 5 is excellent and 1= poor
|
5 minutes
|
|
Subject satisfaction: 5- point scale
Time Frame: 5 minutes
|
The subject's global assessment of satisfaction with the procedure will be assessed using a scale of 1-5, where 5 is excellent
|
5 minutes
|
Collaborators and Investigators
Sponsor
Collaborators
Publications and helpful links
General Publications
- Committee on Adolescent Health Care Long-Acting Reversible Contraception Working Group, The American College of Obstetricians and Gynecologists. Committee opinion no. 539: adolescents and long-acting reversible contraception: implants and intrauterine devices. Obstet Gynecol. 2012 Oct;120(4):983-8. doi: 10.1097/AOG.0b013e3182723b7d.
- Mansour D, Mommers E, Teede H, Sollie-Eriksen B, Graesslin O, Ahrendt HJ, Gemzell-Danielsson K. Clinician satisfaction and insertion characteristics of a new applicator to insert radiopaque Implanon: an open-label, noncontrolled, multicenter trial. Contraception. 2010 Sep;82(3):243-9. doi: 10.1016/j.contraception.2010.04.007. Epub 2010 May 18.
- Mommers E, Blum GF, Gent TG, Peters KP, Sordal TS, Marintcheva-Petrova M. Nexplanon, a radiopaque etonogestrel implant in combination with a next-generation applicator: 3-year results of a noncomparative multicenter trial. Am J Obstet Gynecol. 2012 Nov;207(5):388.e1-6. doi: 10.1016/j.ajog.2012.08.002. Epub 2012 Aug 10.
- Webb AM. Why go to Tiger Country? A report of two cases of Implanon removal. J Fam Plann Reprod Health Care. 2006 Jul;32(3):193-4. doi: 10.1783/147118906777888233. No abstract available.
- Levine JP, Sinofsky FE, Christ MF; Implanon US Study Group. Assessment of Implanon insertion and removal. Contraception. 2008 Nov;78(5):409-17. doi: 10.1016/j.contraception.2008.06.016. Epub 2008 Sep 18.
- Funk S, Miller MM, Mishell DR Jr, Archer DF, Poindexter A, Schmidt J, Zampaglione E; Implanon US Study Group. Safety and efficacy of Implanon, a single-rod implantable contraceptive containing etonogestrel. Contraception. 2005 May;71(5):319-26. doi: 10.1016/j.contraception.2004.11.007.
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
- REVALID03
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.