Endovascular Coiling Using Target Tetra® Coils for Small Intracranial Aneurysm

December 11, 2023 updated by: Yonsei University

Safety and Efficacy of Endovascular Coiling Using Target Tetra® Coils for Small Intracranial Aneurysm: Prospective, Open-label, Single Arm, Single Center Study

The goal of this study was to verify the safety and effectiveness of Target Tetra® Detachable Coil in the endovascular embolization treatment of small intracranial aneurysm (≤5mm).

Study Overview

Status

Not yet recruiting

Detailed Description

The study is a Prospective Single-arm Single-center Registry that aims to assess the safety and efficacy of the Target Tetra Coils in the endovascular treatment of small intracranial aneurysms (≤5mm). The study is not designed as intervention or treatment study. The investigators will enroll up to 100 participants at the single center.

  • Enrollment of patients: The following process is carried out for patients who have consented to participate in the study among non-ruptured or ruptured cerebral aneurysm patients selected based on the inclusion and exclusion criteria.

    • Before the procedure, the following items are verified:

      • Informed consent form
      • Demographic information
      • Past medical history and family history
      • Vital signs
      • Electrocardiogram (ECG) results (results from within the previous 12 weeks before the screening visit can be used)
      • Laboratory test results (results from within the previous 12 weeks before the screening visit can be used): WBC, RBC, Hb, Hct, platelet count, PT INR, aPTT, cholesterol, ALP, AST, ALT, albumin, total bilirubin, total protein, BUN, creatinine, eGFR*, Urine-HCG†, FBS, triglycerides, LDL, PRU (VerifyNow test), and ARU (VerifyNow test) *eGFR = (140 - age) x (weight/72) x Creatinine

        • Pregnancy test (if applicable)
      • Imaging findings (results from within the previous 1 year before the screening visit can be used)
      • Adverse events
      • Concomitant medications/therapies
      • Pre-procedure modified Rankin Scale (mRS) assessment

        ③ Following the established method, coil embolization is performed under general anesthesia, and mechanical or technical failures of the Target Tetra® Detachable Coil occurring during the treatment are investigated.

      • Failure to advance or insert
      • Stretch
      • Disconnection
      • Detachment failure
      • Material deformation
      • Difficult to remove
      • Peeled or delaminated device
      • Premature detachment ④ During the procedure and within 30 days post-procedure, neurological and non-neurological complications are investigated.
      • Neurological complications

        -Any cause of death

        • Any intracranial thromboembolism (asymptomatic or symptomatic)
        • Any intracranial hemorrhage including aneurysm perforation
        • Any intracranial vessel injury
        • Miscellaneous: any ocular hemorrhage
      • Non-neurological complications

        -Puncture site complication requiring any intervention

        -Pseudoaneurysm

        -Arteriovenous (AV) fistula

        -Hematoma requiring transfusion

        -Retroperitoneal hemorrhage

        -Arterial dissection

        • Thromboembolism including limb ischemia
        • Miscellaneous: infection, vessel rupture/perforation
        • Complications related to general anesthesia

          • After the procedure, the occlusion rate of cerebral aneurysms (modified Raymond Scale; complete occlusion, neck remnant, sac remnant) and packing density are evaluated.
      • Modified Raymond Scale
      • Packing Density Packing Density = Volume of coils placed in the aneurysm / Volume of the aneurysm measured on a 3D workstation (%) The above process is conducted through the open-source Angiosuite application.

        ⑥ Characteristics of cerebral aneurysms in patients who have been treated with Target Tetra® Detachable Coils in over 70% of the total packing density are identified.

        ⑦ Clinical outcomes (mRS) are evaluated at 1 month, 6 months, 12 months of follow-up.

<Modified Rankin Scale score>

⑧ At 6 months, 12 months, the occlusion rate of cerebral aneurysms (Modified Raymond Scale) and recurrence are assessed by at least two neurosurgery specialists using 3T-MR angiography or cerebral angiography.

⑨ Patients who have not been treated with Target Tetra® Detachable Coils in over 70% of the total packing density are excluded from the analysis.

The independent Study Monitoring will be regularly proceed and processed on the basis of the permission of instituitional review board.

Study Type

Observational

Enrollment (Estimated)

100

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

N/A

Sampling Method

Non-Probability Sample

Study Population

Adult patients with small-sized intracranial aneurysms measuring 5mm or less require endovascular coil embolization treatment.

Description

Inclusion Criteria:

  1. Adults aged 19 to 80 years
  2. Patients with intracranial aneurysms suitable for endovascular embolization therapy with a maximum diameter of 5mm or less
  3. Including both ruptured and unruptured intracranial aneurysms
  4. Patients for whom the use of Target Tetra® coil is expected in endovascular coil embolization therapy
  5. Patients who have undergone balloon-assisted coiling or adjunctive stent placement during coil embolization
  6. Subjects who have received an explanation of the clinical study and provided written consent to participate in the study

Exclusion Criteria:

  1. Age below 18 or above 81 years
  2. Infectious, dissecting, traumatic, or mycotic aneurysms
  3. Patients who have undergone surgical or endovascular treatment for the target intracranial aneurysm
  4. Patients in whom vascular access to the target intracranial aneurysm is not possible due to conditions such as moyamoya disease, dural arteriovenous malformation, significant atherosclerotic stenosis, or severe vessel tortuosity
  5. Patients with ruptured intracranial aneurysms classified as Hunt and Hess grade 5 (deep coma)
  6. Patients with hypersensitivity reactions to the materials used in the coils, such as platinum, tungsten, nickel, or stainless steel
  7. Patients with serious adverse reactions to contrast agents
  8. Patients who are unable to complete planned follow-up observations due to expected short-term survival or comorbidities
  9. Female patients who are pregnant (positive pregnancy test) or planning pregnancy within 12 months after coil placement, or breastfeeding
  10. Patients with significant renal dysfunction or uncorrected coagulation disorders

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Cohorts and Interventions

Group / Cohort
Tetral Coil Group
Intracranial Aneurysm patients who treated with Target Tetra® coils (70% or more of packing density)

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Time Frame
Anerysm Occlusion Grade : Procedure day Occlusion Grade
Time Frame: Procedure day
Procedure day
Anerysm Occlusion Grade : 6 month Occlusion Grade
Time Frame: 6 months(±30 days) from procedure date
6 months(±30 days) from procedure date
Anerysm Occlusion Grade : 12 month Occulsion Grade
Time Frame: 12 months(±30 days) from procedure date
12 months(±30 days) from procedure date
Aneurysm Packing Density : Packing Density
Time Frame: Procedure day
Procedure day

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Neurological complications
Time Frame: Procedure, 1 month from procedure date
Neurological complications related to the use of the device during the procedure
Procedure, 1 month from procedure date
Non-neurological complications
Time Frame: Procedure, 1 month from procedure date
Non-neurological complications related to the use of the device during the procedure
Procedure, 1 month from procedure date
Device-related events
Time Frame: procedure date
Device-related events during the procedure (malfunction, stretching, early detachment, etc.)
procedure date
Clinical outcomes
Time Frame: Procedure, 1 month, 6 months, 12 months from procedure date
Clinical outcomes observed during the follow-up perio
Procedure, 1 month, 6 months, 12 months from procedure date
Incidence of recurrence and retreatment
Time Frame: Procedure, 6 months, 12 months from procedure date
Incidence of recurrence and retreatment during the follow-up period
Procedure, 6 months, 12 months from procedure date

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Keunyoung PARK, M.D.PhD., Department of Neurosurgery, Yonsei University College of Medicine, Severance Hospital

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

December 1, 2023

Primary Completion (Estimated)

March 1, 2026

Study Completion (Estimated)

March 1, 2026

Study Registration Dates

First Submitted

September 26, 2023

First Submitted That Met QC Criteria

September 26, 2023

First Posted (Actual)

October 3, 2023

Study Record Updates

Last Update Posted (Actual)

December 18, 2023

Last Update Submitted That Met QC Criteria

December 11, 2023

Last Verified

December 1, 2023

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Subscribe