A Safety and Effectiveness Study of the Supira System in Patients Undergoing HRPCI - CE Study (SUPPORT CE)

February 10, 2026 updated by: Supira Medical

The SUPPORT CE Study: A Safety and Effectiveness Study of the SUpira System in Patients Undergoing High-Risk Percutaneous COronaRy InTervention (HRPCI)

The objective of this study is to evaluate the safety and effectiveness of utilizing the Supira System to provide hemodynamic support during HRPCI.

Study Overview

Status

Withdrawn

Intervention / Treatment

Detailed Description

The Supira System is a temporary (≤ 4 hours) ventricular support device indicated for use during elective or urgent high-risk percutaneous coronary interventions (HRPCI) performed in hemodynamically stable patients with severe coronary artery disease when a heart team, including a cardiac surgeon, has determined HRPCI is the appropriate therapeutic option.

Use of the Supira System in these patients may prevent hemodynamic instability which can result from repeat episodes of reversible myocardial ischemia that occur during planned temporary coronary occlusions and may reduce peri- and postprocedural adverse events

Study Type

Interventional

Phase

  • Not Applicable

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  1. Age ≥18 years and ≤90 years
  2. Hemodynamically stable and will undergo elective or urgent (not emergent) HRPCI, where hemodynamic support is deemed necessary as determined by the institutional Heart Team.
  3. Informed consent granted by the patient or legally authorized representative

Exclusion Criteria:

  1. Cardiogenic shock or acutely decompensated pre-existing chronic heart failure a. Note: Cardiogenic shock is defined as: systemic hypotension (systolic blood pressure [BP] <90 mmHg or the need for inotropes/pressors to maintain a systolic BP >90 mmHg) plus one of the following: any requirement for inotropes/pressors prior to arrival at the catheterization laboratory, clinical evidence of end-organ hypoperfusion or use of IABP or any other circulatory support device at time of screening.
  2. Stroke within 6 months of the index procedure, or any prior stroke with permanent neurologic deficit
  3. Evidence of left ventricular thrombus as assessed by Transthoracic Echocardiogram (TTE)
  4. Aortic valvular disease or regurgitation categorized as moderate or greater (≥ 2+ on a 4-grade scale as assessed on TTE)
  5. Aortic valve stenosis categorized as moderate or greater (gradient >20 mmHg or valve area <1.5 cm2 as assessed on TTE)
  6. Previous aortic valve replacement or repair
  7. Ascending or descending aortic dissection or aortic aneurysm >4.5 cm
  8. Aortic and iliofemoral anatomical conditions that preclude safe delivery and placement of the investigational device
  9. Presence of decompensated liver disease; severe liver dysfunction (Child class C)
  10. Ongoing renal replacement therapy with dialysis
  11. Infection of the proposed procedural access site or active systemic infection requiring ongoing antibiotic therapy
  12. Heparin-induced thrombocytopenia, current or any prior occurrences
  13. Known hypersensitivity to intravenous contrast agents that cannot be adequately pre-medicated or known hypersensitivity to heparin, aspirin, adenosine diphosphate (ADP) receptor inhibitors, or nitinol
  14. Known or suspected coagulopathy or abnormal coagulation parameters (defined as platelet count ≤ 100,000/mm³ or spontaneous International Normalized Ratio (INR) ≥ 1.5 or known fibrinogen ≤ 1.5 g/L)
  15. Any condition or scheduled surgery that will require discontinuation of antiplatelet and/or anticoagulant therapy within 90 days of the index procedure
  16. Planned coronary intervention within 30 days prior or post index procedure
  17. Breastfeeding or pregnant or planning to become pregnant within 90 days of the HRPCI procedure
  18. Currently participating in active follow-up phase of another clinical study of an investigational drug or device or planning to enroll in such a study within 90 days of the HRPCI procedure
  19. Active COVID-related infection or prior COVID-19 diagnosis with sequelae that could confound endpoint assessments
  20. Other medical, social, or psychological problems that would have them be considered in any way to be part of a vulnerable population. This includes individuals who may have difficulty providing informed consent or are at a higher risk of coercion or undue influence, individuals permanently incapable of giving informed consent, and individuals whose ability to comply with study procedures may be compromised, in the opinion of the Investigator

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Supira System
Ventricular support indicated for use during elective or urgent high-risk percutaneous coronary interventions.
The Supira System is a minimally invasive, miniaturized percutaneous ventricular assist (pVAD) system that is intended to provide temporary (≤4 hours) hemodynamic support to patients undergoing a high-risk percutaneous coronary intervention (HRPCI). The Catheter is inserted percutaneously via the femoral artery, across the aortic valve, and into the left ventricle under fluoroscopic guidance, with a portion remaining in the ascending aorta. The left ventricle is unloaded by pumping blood from the ventricle into the ascending aorta and systemic circulation.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Successful initiation and maintenance of hemodynamic support
Time Frame: 90 days from procedure

A composite endpoint of safety and effectiveness outcomes, evaluated at 90 days, comprises the following outcomes:

  • All-cause death
  • Myocardial infarction (MI)
  • Stroke or transient ischemic attack (TIA)
  • Unplanned repeat revascularization
  • Major bleeding (BARC ³ 3)
  • Major vascular complications (MCS-ARC defined)
  • Sustained hypotension during mechanical circulatory support
90 days from procedure

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Procedural Success
Time Frame: 90 days from procedure

Freedom from:

  1. Major bleeding (BARC ³ 3)
  2. Major vascular complications (MCS-ARC defined)
  3. Sustained hypotension during mechanical circulatory support
  4. Need for mechanical circulatory support beyond the index procedure
90 days from procedure

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

January 1, 2024

Primary Completion (Estimated)

September 1, 2026

Study Completion (Estimated)

September 1, 2026

Study Registration Dates

First Submitted

August 19, 2024

First Submitted That Met QC Criteria

August 19, 2024

First Posted (Actual)

August 21, 2024

Study Record Updates

Last Update Posted (Actual)

February 12, 2026

Last Update Submitted That Met QC Criteria

February 10, 2026

Last Verified

February 1, 2026

More Information

Terms related to this study

Other Study ID Numbers

  • CP-10006

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

Yes

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.