Investigating the Relationship Between Measures of the Hearing Nerve and Speech Perception Outcomes in Adult Nexa Cochlear Implant Recipients (NODE-SDN)

November 16, 2026 updated by: Cochlear

Prospective, Interventional, Multicentre Feasibility Investigation Evaluating Objective Measures and Clinical Outcomes in Adult Nexa® Cochlear Implant Recipients

This study aims to learn more about the information that can be obtained directly from measurements through a Nexa cochlear implant during and after surgery. Researchers will investigate whether these measurements can help understand how the implant is interacting with the inner ear and hearing nerve, where the electrodes are positioned inside the cochlea, and potentially how the implant should be programmed and how well a person detects sounds.

The study will also evaluate how well two methods agree in determining the position of the electrode contacts relative to the anatomy of the inner ear and the hearing nerve. One method uses measurements after surgery made through the implant itself. The other uses medical Computed Tomography(CT) imaging made after the surgery. The information collected will also contribute to a clinical research database that may be used to support future research and development. Participants will be told about this potential future use when they provide consent.

Study Overview

Status

Not yet recruiting

Intervention / Treatment

Study Type

Interventional

Enrollment (Estimated)

200

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Contact Backup

Study Locations

    • Victoria
      • East Melbourne, Victoria, Australia, 3002
        • The University of Melbourne, Royal Victorian Eye and Ear Hospital
        • Principal Investigator:
          • Stephen O'Leary, MBBS, PhD, FRACS
    • Antwerp
      • Wilrijk, Antwerp, Belgium, 2610
        • Sint Augustinus ENT European Institute for ORL-HNS
        • Principal Investigator:
          • Andrzej Zarowski, MD
    • Lower Saxony
      • Hanover, Lower Saxony, Germany, 30625
        • Medizinische Hochschule Hannover
        • Principal Investigator:
          • Andreas Büchner, PhD
    • Missouri
      • St Louis, Missouri, United States, 63141
        • Washington University School of Medicine Ear, Nose & Throat Centre
        • Principal Investigator:
          • Amit Walia, MD
    • Utah
      • Salt Lake City, Utah, United States, 84132
        • University of Utah Hospitals and Clinics
        • Principal Investigator:
          • Craig Buchman, MD

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  1. Aged 18 years or older (no upper age limit).
  2. Candidate for CI1032 cochlear implantation as per the local sensorineural hearing loss criteria.
  3. Sufficient proficiency in the language used to conduct the study procedures, as determined by the investigator.
  4. Availability of pre-op CT scan of the cochlear region meeting quality requirements as determined by the sponsor.
  5. Willing and able to provide written informed consent and to comply with all requirements of the protocol.

Exclusion Criteria:

  1. Previous cochlear implantation in the same ear.
  2. Cochlear implant in the contralateral ear.
  3. Have an unaided air conduction pure tone average (average of unaided thresholds at 0.5, 1, 2 and 4 kHz) ≤40 dB HL in the contralateral ear measured within the last 12 months
  4. Severe or greater sensorineural hearing loss prior to 2 years of age, as documented in medical history.
  5. Deafness due to lesions of the auditory nerve or central auditory pathway.
  6. Cochlear ossification or anatomical anomaly precluding full electrode array insertion.
  7. Diagnosis of auditory neuropathy.
  8. Additional conditions preventing or restricting participation in the audiological evaluations, as determined by the investigator.
  9. Pregnant or breastfeeding women.
  10. Unrealistic expectations on the part of the subject regarding the potential benefits, risks, and limitations of the surgical procedure and device.
  11. Unable or unwilling to comply with the requirements of the clinical investigation as determined by the Investigator.
  12. Investigator site personnel directly affiliated with this study and/or their immediate families; immediate family is defined as a spouse, parent, child, or sibling.
  13. Cochlear employees or employees of Contract Research Organisations or contractors engaged by Cochlear for the purposes of this investigation.
  14. Current participation, or participation in another interventional clinical study/trial in the past 30 days, involving an investigational drug or device (unless determined by the Sponsor to not impact this investigation).

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Diagnostic
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Cochlear implant recipients

Adult participants receiving a commercial Cochlear Nucleus Nexa cochlear implant, who undergo additional investigational objective measure procedures performed intra- and post-operatively.

Participants will be tested with intra- and post-operative objective measures, including Transimpedance Matrix (TIM) and Neural Response telemetry (NRT) recordings, using monopolar and focused multipolar stimulation.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Correlation Between CT-Derived Electrode-to-Modiolus Distance and MAP T-Levels
Time Frame: Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation

The correlation between electrode-to-modiolus distance (in millimeters, mm) derived from postoperative computed tomography (CT) imaging and cochlear implant MAP threshold (T) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between electrode position and MAP T-levels.

Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation
Correlation Between CT-Derived Electrode-to-Modiolus Distance and MAP C-Levels
Time Frame: Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation

The correlation between electrode-to-modiolus distance (in millimeters, mm) derived from postoperative CT imaging and cochlear implant MAP maximum comfortable (C) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between electrode position and MAP C-levels.

Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation
Correlation Between CT-Derived Electrode-to-Modiolus Distance and Aided Pure-Tone Thresholds
Time Frame: Postoperative CT assessment and aided hearing assessment at 6 months post-activation.

The correlation between electrode-to-modiolus distance (in millimeters, mm) derived from postoperative CT imaging and aided pure-tone thresholds (in dBHL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between electrode position and aided hearing thresholds.

Postoperative CT assessment and aided hearing assessment at 6 months post-activation.
Correlation Between Monopolar T-NRT Thresholds and MAP T-Levels
Time Frame: At 6 months post-activation.

The correlation between monopolar telemetry neural response threshold (T-NRT) measurements and cochlear implant MAP threshold (T) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between monopolar T-NRT thresholds and MAP T-levels.

At 6 months post-activation.
Correlation Between Monopolar T-NRT Thresholds and MAP C-Levels
Time Frame: At 6 months post-activation.

The correlation between monopolar telemetry neural response threshold (T-NRT) measurements and cochlear implant MAP maximum comfortable (C) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between monopolar T-NRT thresholds and MAP C-levels.

At 6 months post-activation.
Correlation Between Monopolar T-NRT Thresholds and Aided Pure-Tone Thresholds
Time Frame: At 6 months post-activation.

The correlation between monopolar telemetry neural response threshold (T-NRT) measurements (in current level, CL) and aided pure-tone thresholds (in dBHL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between monopolar T-NRT thresholds and aided hearing thresholds.

At 6 months post-activation.
Correlation Between Focused T-NRT Thresholds and MAP T-Levels
Time Frame: At 6 months post-activation.

The correlation between focused telemetry neural response threshold (T-NRT) measurements (in current level, CL) and cochlear implant MAP threshold (T) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between focused T-NRT thresholds and MAP T-levels.

At 6 months post-activation.
Correlation Between Focused T-NRT Thresholds and MAP C-Levels
Time Frame: At 6 months post-activation.

The correlation between focused telemetry neural response threshold (T-NRT) measurements (in current level, CL) and cochlear implant MAP maximum comfortable (C) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals. will be reported to characterize the strength and direction of the association between focused T-NRT thresholds and MAP C-levels.

At 6 months post-activation.
Correlation Between Focused T-NRT Thresholds and Aided Pure-Tone Thresholds
Time Frame: At 6 months post-activation.

The correlation between focused telemetry neural response threshold (T-NRT) measurements (in current level, CL) and aided pure-tone thresholds (in dBHL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between focused T-NRT thresholds and aided hearing thresholds.

At 6 months post-activation.

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Mean Absolute Error Between TIM-Derived and CT-Derived Electrode-to-Modiolus Distance
Time Frame: At 6 months post-activation

Postoperative electrode-to-modiolus distance for individual electrode contacts will be determined using postoperative computed tomography (CT) imaging and using Transimpedance Matrix (TIM) measurements analysed with an algorithm. The mean absolute error between paired TIM-derived and CT-derived electrode-to-modiolus distance measurements will be reported in millimetres (mm).

At 6 months post-activation

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

January 1, 2027

Primary Completion (Estimated)

August 1, 2028

Study Completion (Estimated)

August 1, 2028

Study Registration Dates

First Submitted

November 9, 2026

First Submitted That Met QC Criteria

November 16, 2026

First Posted (Actual)

November 23, 2026

Study Record Updates

Last Update Posted (Actual)

November 23, 2026

Last Update Submitted That Met QC Criteria

November 16, 2026

Last Verified

November 1, 2026

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

Yes

product manufactured in and exported from the U.S.

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Subscribe