Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Investigating the Relationship Between Measures of the Hearing Nerve and Speech Perception Outcomes in Adult Nexa Cochlear Implant Recipients (NODE-SDN)

16 novembre 2026 aggiornato da: Cochlear

Prospective, Interventional, Multicentre Feasibility Investigation Evaluating Objective Measures and Clinical Outcomes in Adult Nexa® Cochlear Implant Recipients

This study aims to learn more about the information that can be obtained directly from measurements through a Nexa cochlear implant during and after surgery. Researchers will investigate whether these measurements can help understand how the implant is interacting with the inner ear and hearing nerve, where the electrodes are positioned inside the cochlea, and potentially how the implant should be programmed and how well a person detects sounds.

The study will also evaluate how well two methods agree in determining the position of the electrode contacts relative to the anatomy of the inner ear and the hearing nerve. One method uses measurements after surgery made through the implant itself. The other uses medical Computed Tomography(CT) imaging made after the surgery. The information collected will also contribute to a clinical research database that may be used to support future research and development. Participants will be told about this potential future use when they provide consent.

Panoramica dello studio

Stato

Non ancora reclutamento

Intervento / Trattamento

Tipo di studio

Interventistico

Iscrizione (Stimato)

200

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Backup dei contatti dello studio

Luoghi di studio

    • Victoria
      • East Melbourne, Victoria, Australia, 3002
        • The University of Melbourne, Royal Victorian Eye and Ear Hospital
        • Investigatore principale:
          • Stephen O'Leary, MBBS, PhD, FRACS
    • Antwerp
      • Wilrijk, Antwerp, Belgio, 2610
        • Sint Augustinus ENT European Institute for ORL-HNS
        • Investigatore principale:
          • Andrzej Zarowski, MD
    • Lower Saxony
      • Hanover, Lower Saxony, Germania, 30625
        • Medizinische Hochschule Hannover
        • Investigatore principale:
          • Andreas Büchner, PhD
    • Missouri
      • St Louis, Missouri, Stati Uniti, 63141
        • Washington University School of Medicine Ear, Nose & Throat Centre
        • Investigatore principale:
          • Amit Walia, MD
    • Utah
      • Salt Lake City, Utah, Stati Uniti, 84132
        • University of Utah Hospitals and Clinics
        • Investigatore principale:
          • Craig Buchman, MD

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  1. Aged 18 years or older (no upper age limit).
  2. Candidate for CI1032 cochlear implantation as per the local sensorineural hearing loss criteria.
  3. Sufficient proficiency in the language used to conduct the study procedures, as determined by the investigator.
  4. Availability of pre-op CT scan of the cochlear region meeting quality requirements as determined by the sponsor.
  5. Willing and able to provide written informed consent and to comply with all requirements of the protocol.

Exclusion Criteria:

  1. Previous cochlear implantation in the same ear.
  2. Cochlear implant in the contralateral ear.
  3. Have an unaided air conduction pure tone average (average of unaided thresholds at 0.5, 1, 2 and 4 kHz) ≤40 dB HL in the contralateral ear measured within the last 12 months
  4. Severe or greater sensorineural hearing loss prior to 2 years of age, as documented in medical history.
  5. Deafness due to lesions of the auditory nerve or central auditory pathway.
  6. Cochlear ossification or anatomical anomaly precluding full electrode array insertion.
  7. Diagnosis of auditory neuropathy.
  8. Additional conditions preventing or restricting participation in the audiological evaluations, as determined by the investigator.
  9. Pregnant or breastfeeding women.
  10. Unrealistic expectations on the part of the subject regarding the potential benefits, risks, and limitations of the surgical procedure and device.
  11. Unable or unwilling to comply with the requirements of the clinical investigation as determined by the Investigator.
  12. Investigator site personnel directly affiliated with this study and/or their immediate families; immediate family is defined as a spouse, parent, child, or sibling.
  13. Cochlear employees or employees of Contract Research Organisations or contractors engaged by Cochlear for the purposes of this investigation.
  14. Current participation, or participation in another interventional clinical study/trial in the past 30 days, involving an investigational drug or device (unless determined by the Sponsor to not impact this investigation).

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Diagnostico
  • Assegnazione: N / A
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: Cochlear implant recipients

Adult participants receiving a commercial Cochlear Nucleus Nexa cochlear implant, who undergo additional investigational objective measure procedures performed intra- and post-operatively.

Participants will be tested with intra- and post-operative objective measures, including Transimpedance Matrix (TIM) and Neural Response telemetry (NRT) recordings, using monopolar and focused multipolar stimulation.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Correlation Between CT-Derived Electrode-to-Modiolus Distance and MAP T-Levels
Lasso di tempo: Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation

The correlation between electrode-to-modiolus distance (in millimeters, mm) derived from postoperative computed tomography (CT) imaging and cochlear implant MAP threshold (T) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between electrode position and MAP T-levels.

Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation
Correlation Between CT-Derived Electrode-to-Modiolus Distance and MAP C-Levels
Lasso di tempo: Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation

The correlation between electrode-to-modiolus distance (in millimeters, mm) derived from postoperative CT imaging and cochlear implant MAP maximum comfortable (C) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between electrode position and MAP C-levels.

Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation
Correlation Between CT-Derived Electrode-to-Modiolus Distance and Aided Pure-Tone Thresholds
Lasso di tempo: Postoperative CT assessment and aided hearing assessment at 6 months post-activation.

The correlation between electrode-to-modiolus distance (in millimeters, mm) derived from postoperative CT imaging and aided pure-tone thresholds (in dBHL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between electrode position and aided hearing thresholds.

Postoperative CT assessment and aided hearing assessment at 6 months post-activation.
Correlation Between Monopolar T-NRT Thresholds and MAP T-Levels
Lasso di tempo: At 6 months post-activation.

The correlation between monopolar telemetry neural response threshold (T-NRT) measurements and cochlear implant MAP threshold (T) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between monopolar T-NRT thresholds and MAP T-levels.

At 6 months post-activation.
Correlation Between Monopolar T-NRT Thresholds and MAP C-Levels
Lasso di tempo: At 6 months post-activation.

The correlation between monopolar telemetry neural response threshold (T-NRT) measurements and cochlear implant MAP maximum comfortable (C) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between monopolar T-NRT thresholds and MAP C-levels.

At 6 months post-activation.
Correlation Between Monopolar T-NRT Thresholds and Aided Pure-Tone Thresholds
Lasso di tempo: At 6 months post-activation.

The correlation between monopolar telemetry neural response threshold (T-NRT) measurements (in current level, CL) and aided pure-tone thresholds (in dBHL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between monopolar T-NRT thresholds and aided hearing thresholds.

At 6 months post-activation.
Correlation Between Focused T-NRT Thresholds and MAP T-Levels
Lasso di tempo: At 6 months post-activation.

The correlation between focused telemetry neural response threshold (T-NRT) measurements (in current level, CL) and cochlear implant MAP threshold (T) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between focused T-NRT thresholds and MAP T-levels.

At 6 months post-activation.
Correlation Between Focused T-NRT Thresholds and MAP C-Levels
Lasso di tempo: At 6 months post-activation.

The correlation between focused telemetry neural response threshold (T-NRT) measurements (in current level, CL) and cochlear implant MAP maximum comfortable (C) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals. will be reported to characterize the strength and direction of the association between focused T-NRT thresholds and MAP C-levels.

At 6 months post-activation.
Correlation Between Focused T-NRT Thresholds and Aided Pure-Tone Thresholds
Lasso di tempo: At 6 months post-activation.

The correlation between focused telemetry neural response threshold (T-NRT) measurements (in current level, CL) and aided pure-tone thresholds (in dBHL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between focused T-NRT thresholds and aided hearing thresholds.

At 6 months post-activation.

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Mean Absolute Error Between TIM-Derived and CT-Derived Electrode-to-Modiolus Distance
Lasso di tempo: At 6 months post-activation

Postoperative electrode-to-modiolus distance for individual electrode contacts will be determined using postoperative computed tomography (CT) imaging and using Transimpedance Matrix (TIM) measurements analysed with an algorithm. The mean absolute error between paired TIM-derived and CT-derived electrode-to-modiolus distance measurements will be reported in millimetres (mm).

At 6 months post-activation

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

1 gennaio 2027

Completamento primario (Stimato)

1 agosto 2028

Completamento dello studio (Stimato)

1 agosto 2028

Date di iscrizione allo studio

Primo inviato

9 novembre 2026

Primo inviato che soddisfa i criteri di controllo qualità

16 novembre 2026

Primo Inserito (Effettivo)

23 novembre 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

23 novembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

16 novembre 2026

Ultimo verificato

1 novembre 2026

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

Sì

prodotto fabbricato ed esportato dagli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi