Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Investigating the Relationship Between Measures of the Hearing Nerve and Speech Perception Outcomes in Adult Nexa Cochlear Implant Recipients (NODE-SDN)

16. november 2026 opdateret af: Cochlear

Prospective, Interventional, Multicentre Feasibility Investigation Evaluating Objective Measures and Clinical Outcomes in Adult Nexa® Cochlear Implant Recipients

This study aims to learn more about the information that can be obtained directly from measurements through a Nexa cochlear implant during and after surgery. Researchers will investigate whether these measurements can help understand how the implant is interacting with the inner ear and hearing nerve, where the electrodes are positioned inside the cochlea, and potentially how the implant should be programmed and how well a person detects sounds.

The study will also evaluate how well two methods agree in determining the position of the electrode contacts relative to the anatomy of the inner ear and the hearing nerve. One method uses measurements after surgery made through the implant itself. The other uses medical Computed Tomography(CT) imaging made after the surgery. The information collected will also contribute to a clinical research database that may be used to support future research and development. Participants will be told about this potential future use when they provide consent.

Studieoversigt

Status

Ikke rekrutterer endnu

Intervention / Behandling

Undersøgelsestype

Interventionel

Tilmelding (Anslået)

200

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiekontakt

Undersøgelse Kontakt Backup

Studiesteder

    • Victoria
      • East Melbourne, Victoria, Australien, 3002
        • The University of Melbourne, Royal Victorian Eye and Ear Hospital
        • Ledende efterforsker:
          • Stephen O'Leary, MBBS, PhD, FRACS
    • Antwerp
      • Wilrijk, Antwerp, Belgien, 2610
        • Sint Augustinus ENT European Institute for ORL-HNS
        • Ledende efterforsker:
          • Andrzej Zarowski, MD
    • Missouri
      • St Louis, Missouri, Forenede Stater, 63141
        • Washington University School of Medicine Ear, Nose & Throat Centre
        • Ledende efterforsker:
          • Amit Walia, MD
    • Utah
      • Salt Lake City, Utah, Forenede Stater, 84132
        • University of Utah Hospitals and Clinics
        • Ledende efterforsker:
          • Craig Buchman, MD
    • Lower Saxony
      • Hanover, Lower Saxony, Tyskland, 30625
        • Medizinische Hochschule Hannover
        • Ledende efterforsker:
          • Andreas Büchner, PhD

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år og ældre (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  1. Aged 18 years or older (no upper age limit).
  2. Candidate for CI1032 cochlear implantation as per the local sensorineural hearing loss criteria.
  3. Sufficient proficiency in the language used to conduct the study procedures, as determined by the investigator.
  4. Availability of pre-op CT scan of the cochlear region meeting quality requirements as determined by the sponsor.
  5. Willing and able to provide written informed consent and to comply with all requirements of the protocol.

Exclusion Criteria:

  1. Previous cochlear implantation in the same ear.
  2. Cochlear implant in the contralateral ear.
  3. Have an unaided air conduction pure tone average (average of unaided thresholds at 0.5, 1, 2 and 4 kHz) ≤40 dB HL in the contralateral ear measured within the last 12 months
  4. Severe or greater sensorineural hearing loss prior to 2 years of age, as documented in medical history.
  5. Deafness due to lesions of the auditory nerve or central auditory pathway.
  6. Cochlear ossification or anatomical anomaly precluding full electrode array insertion.
  7. Diagnosis of auditory neuropathy.
  8. Additional conditions preventing or restricting participation in the audiological evaluations, as determined by the investigator.
  9. Pregnant or breastfeeding women.
  10. Unrealistic expectations on the part of the subject regarding the potential benefits, risks, and limitations of the surgical procedure and device.
  11. Unable or unwilling to comply with the requirements of the clinical investigation as determined by the Investigator.
  12. Investigator site personnel directly affiliated with this study and/or their immediate families; immediate family is defined as a spouse, parent, child, or sibling.
  13. Cochlear employees or employees of Contract Research Organisations or contractors engaged by Cochlear for the purposes of this investigation.
  14. Current participation, or participation in another interventional clinical study/trial in the past 30 days, involving an investigational drug or device (unless determined by the Sponsor to not impact this investigation).

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Diagnostisk
  • Tildeling: N/A
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: Cochlear implant recipients

Adult participants receiving a commercial Cochlear Nucleus Nexa cochlear implant, who undergo additional investigational objective measure procedures performed intra- and post-operatively.

Participants will be tested with intra- and post-operative objective measures, including Transimpedance Matrix (TIM) and Neural Response telemetry (NRT) recordings, using monopolar and focused multipolar stimulation.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Correlation Between CT-Derived Electrode-to-Modiolus Distance and MAP T-Levels
Tidsramme: Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation

The correlation between electrode-to-modiolus distance (in millimeters, mm) derived from postoperative computed tomography (CT) imaging and cochlear implant MAP threshold (T) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between electrode position and MAP T-levels.

Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation
Correlation Between CT-Derived Electrode-to-Modiolus Distance and MAP C-Levels
Tidsramme: Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation

The correlation between electrode-to-modiolus distance (in millimeters, mm) derived from postoperative CT imaging and cochlear implant MAP maximum comfortable (C) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between electrode position and MAP C-levels.

Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation
Correlation Between CT-Derived Electrode-to-Modiolus Distance and Aided Pure-Tone Thresholds
Tidsramme: Postoperative CT assessment and aided hearing assessment at 6 months post-activation.

The correlation between electrode-to-modiolus distance (in millimeters, mm) derived from postoperative CT imaging and aided pure-tone thresholds (in dBHL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between electrode position and aided hearing thresholds.

Postoperative CT assessment and aided hearing assessment at 6 months post-activation.
Correlation Between Monopolar T-NRT Thresholds and MAP T-Levels
Tidsramme: At 6 months post-activation.

The correlation between monopolar telemetry neural response threshold (T-NRT) measurements and cochlear implant MAP threshold (T) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between monopolar T-NRT thresholds and MAP T-levels.

At 6 months post-activation.
Correlation Between Monopolar T-NRT Thresholds and MAP C-Levels
Tidsramme: At 6 months post-activation.

The correlation between monopolar telemetry neural response threshold (T-NRT) measurements and cochlear implant MAP maximum comfortable (C) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between monopolar T-NRT thresholds and MAP C-levels.

At 6 months post-activation.
Correlation Between Monopolar T-NRT Thresholds and Aided Pure-Tone Thresholds
Tidsramme: At 6 months post-activation.

The correlation between monopolar telemetry neural response threshold (T-NRT) measurements (in current level, CL) and aided pure-tone thresholds (in dBHL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between monopolar T-NRT thresholds and aided hearing thresholds.

At 6 months post-activation.
Correlation Between Focused T-NRT Thresholds and MAP T-Levels
Tidsramme: At 6 months post-activation.

The correlation between focused telemetry neural response threshold (T-NRT) measurements (in current level, CL) and cochlear implant MAP threshold (T) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between focused T-NRT thresholds and MAP T-levels.

At 6 months post-activation.
Correlation Between Focused T-NRT Thresholds and MAP C-Levels
Tidsramme: At 6 months post-activation.

The correlation between focused telemetry neural response threshold (T-NRT) measurements (in current level, CL) and cochlear implant MAP maximum comfortable (C) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals. will be reported to characterize the strength and direction of the association between focused T-NRT thresholds and MAP C-levels.

At 6 months post-activation.
Correlation Between Focused T-NRT Thresholds and Aided Pure-Tone Thresholds
Tidsramme: At 6 months post-activation.

The correlation between focused telemetry neural response threshold (T-NRT) measurements (in current level, CL) and aided pure-tone thresholds (in dBHL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between focused T-NRT thresholds and aided hearing thresholds.

At 6 months post-activation.

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Mean Absolute Error Between TIM-Derived and CT-Derived Electrode-to-Modiolus Distance
Tidsramme: At 6 months post-activation

Postoperative electrode-to-modiolus distance for individual electrode contacts will be determined using postoperative computed tomography (CT) imaging and using Transimpedance Matrix (TIM) measurements analysed with an algorithm. The mean absolute error between paired TIM-derived and CT-derived electrode-to-modiolus distance measurements will be reported in millimetres (mm).

At 6 months post-activation

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Sponsor

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Anslået)

1. januar 2027

Primær færdiggørelse (Anslået)

1. august 2028

Studieafslutning (Anslået)

1. august 2028

Datoer for studieregistrering

Først indsendt

9. november 2026

Først indsendt, der opfyldte QC-kriterier

16. november 2026

Først opslået (Faktiske)

23. november 2026

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

23. november 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

16. november 2026

Sidst verificeret

1. november 2026

Mere information

Begreber relateret til denne undersøgelse

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ja

produkt fremstillet i og eksporteret fra U.S.A.

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Abonner