Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Correlation Study of Imaging Data Acquired During CABG With Data Acquired in the Cath Lab (PERSEUS)

23. srpna 2019 aktualizováno: Dr Ashesh N. Buch, East Carolina University

Collaborative Pilot Study to Determine the Correlation Between Intra-Operative Observations Using SPY® Near Infra-Red Imaging and Cardiac Catheterization Laboratory Physiological Assessment of Lesion Severity (PERSEUS Pilot Study)

Visual assessment of a coronary artery narrowing (called stenosis) seen on angiography is conventionally used to infer how likely the stenosis will limit blood flow (called ischemia) under conditions of increased demand (e.g exercise). This is based on animal work and data from humans with simple single vessel disease with no co-existing conditions. These data have been extrapolated to more complex patients/ complex disease but clearly over-simplifies the situation in the majority of patients cardiologists treat.

Pivotal work by DeBruyne, Pils and colleagues in the 90's convincingly showed that pressure derived measurements, called FFR, from the coronary artery during a cardiac catheterization, more accurately identify stenoses that would cause ischemia compared to visual assessment alone. A strategy of FFR guided coronary stenting with drug eluting stents significantly improved outcomes and reduced costs compared to visual assessment alone (FAME trial). Deferring treatment based on FFR has been shown to be safe (DEFER Trial). FFR has excellent sensitivity and specificity. A FFR of <=0.80 was used as this identified ischemia causing lesions 90% of the time. Therefore, the concept of FFR guided percutaneous revascularisation and treatment deferral has a robust evidence base to support it.

Coronary bypass grafting (CABG) is traditionally based solely on a visual assessment of angiography images. SPY® Infrared Fluorescence Angiography (NIRF, FDA approved 2005) is used by some cardiac surgeons to assess the patency of bypass grafts in real-time in the operating room, as a surrogate for immediate traditional coronary angiography. Dr. Ferguson observed that regional myocardial perfusion (RMP) image data was also captured in these video sequences.

Study Hypotheses:

  1. In patients who are likely CABG candidates, target vessel epicardial coronary arteries (TVECAs) with FFR > 0.80 will not demonstrate an increase in RMP despite an anatomically patent bypass conduit during SPY® imaging.
  2. In TVECAs with an increase in RMP during SPY® imaging, cardiac catheter laboratory measures of coronary physiology from that TVECA, namely one or a combination of FFR, CFR, HSR and HMR, will correlate with the SPY® data on myocardial perfusion, and suggest a potential mechanism for this physiologic response to TVECA grafting.

Přehled studie

Typ studie

Intervenční

Zápis (Aktuální)

1

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

    • North Carolina
      • Greenville, North Carolina, Spojené státy, 27834
        • East Carolina Heart Institute at Vidant Medical Center

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

18 let až 80 let (Dospělý, Starší dospělý)

Přijímá zdravé dobrovolníky

Ne

Pohlaví způsobilá ke studiu

Všechno

Popis

Inclusion Criteria:

  • Age >18<80
  • Patients with stable angina or NSTEMI with total CK rise of <1000 U/litre who after planned coronary angiography are going to be referred for CABG and have at least one vessel with a visual 40-80% stenosis that is interrogated with intracoronary physiology

Exclusion Criteria:

  • Emergent status, or Cardiogenic shock
  • LVEF <40%
  • History of actively malignant disease
  • Patient needing concomitant valvular surgery or other cardiac structural reconstructive surgery
  • As is standard of care, those vessels that are extremely tortuous, very small caliber and/or heavily calcified would not have such wires passed down them. Furthermore, those vessels that are 80-90+% stenosed, with <TIMI 3 flow, which we would not normally pass a diagnostic physiology pressure wire, would not be studied with ComboXT wire.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Diagnostický
  • Přidělení: N/A
  • Intervenční model: Přiřazení jedné skupiny
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Jiný: Patients referred for CABG
  • Patients who after undergoing standard of care diagnostic coronary angiography will be referred for CABG
  • ComboMap XT Guidewire
  • 'SPY' NIRF During CABG
Intracoronary pressure and flow measurements
FDA approved use of injection of indocyanine green for the purposes of performing pre and post coronary grafting graft patency and perfusion assessment with the SPY near infra red fluorescence system

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Correlation Analysis
Časové okno: 18 months
Correlation between anatomy, functional anatomy, FFR, SPY® RMP change, and the presence or absence of imaged competitive flow
18 months

Další výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Correlation Analysis
Časové okno: 18 months
Correlation analysis between anatomy, functional anatomy, FFR, CFR, HMR and SPY® perfusion data for each TVECA and perfusion territory.
18 months
Instantaneous Wave Free Ratio (iFR)
Časové okno: 18 months
Offline analysis of de-identified encrypted data for each TVECA interrogated with ComboMap XT wire by Dr Justin Davies's research group, Imperial College, London for iFR determination. Correlation analysis between iFR and presence or absence of imaged competitive flow and intra-operative RMP data on SPY® NIRF
18 months
Wave Intensity Analysis (WIA)
Časové okno: 18 months
Offline wave wave intensity analysis (WIA) of de-identified encrypted data for each TVECA interrogated with ComboMap XT wire by Dr Justin Davies's research group, Imperial College, London. Correlation analysis between WIA data and presence or absence of imaged competitive flow and intra-operative RMP data on SPY® NIRF
18 months

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Vrchní vyšetřovatel: Ashesh N Buch, MBChB, MD, East Carolina University
  • Vrchní vyšetřovatel: T. Bruce Ferguson, MD, East Carolina University

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia

1. prosince 2014

Primární dokončení (Aktuální)

30. března 2018

Dokončení studie (Aktuální)

30. března 2019

Termíny zápisu do studia

První předloženo

12. května 2014

První předloženo, které splnilo kritéria kontroly kvality

12. května 2014

První zveřejněno (Odhad)

14. května 2014

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

28. srpna 2019

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

23. srpna 2019

Naposledy ověřeno

1. srpna 2019

Více informací

Termíny související s touto studií

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ano

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Klinické studie na ComboMap XT Guidewire

Předplatit