Correlation Study of Imaging Data Acquired During CABG With Data Acquired in the Cath Lab (PERSEUS)
Collaborative Pilot Study to Determine the Correlation Between Intra-Operative Observations Using SPY® Near Infra-Red Imaging and Cardiac Catheterization Laboratory Physiological Assessment of Lesion Severity (PERSEUS Pilot Study)
Visual assessment of a coronary artery narrowing (called stenosis) seen on angiography is conventionally used to infer how likely the stenosis will limit blood flow (called ischemia) under conditions of increased demand (e.g exercise). This is based on animal work and data from humans with simple single vessel disease with no co-existing conditions. These data have been extrapolated to more complex patients/ complex disease but clearly over-simplifies the situation in the majority of patients cardiologists treat.
Pivotal work by DeBruyne, Pils and colleagues in the 90's convincingly showed that pressure derived measurements, called FFR, from the coronary artery during a cardiac catheterization, more accurately identify stenoses that would cause ischemia compared to visual assessment alone. A strategy of FFR guided coronary stenting with drug eluting stents significantly improved outcomes and reduced costs compared to visual assessment alone (FAME trial). Deferring treatment based on FFR has been shown to be safe (DEFER Trial). FFR has excellent sensitivity and specificity. A FFR of <=0.80 was used as this identified ischemia causing lesions 90% of the time. Therefore, the concept of FFR guided percutaneous revascularisation and treatment deferral has a robust evidence base to support it.
Coronary bypass grafting (CABG) is traditionally based solely on a visual assessment of angiography images. SPY® Infrared Fluorescence Angiography (NIRF, FDA approved 2005) is used by some cardiac surgeons to assess the patency of bypass grafts in real-time in the operating room, as a surrogate for immediate traditional coronary angiography. Dr. Ferguson observed that regional myocardial perfusion (RMP) image data was also captured in these video sequences.
Study Hypotheses:
- In patients who are likely CABG candidates, target vessel epicardial coronary arteries (TVECAs) with FFR > 0.80 will not demonstrate an increase in RMP despite an anatomically patent bypass conduit during SPY® imaging.
- In TVECAs with an increase in RMP during SPY® imaging, cardiac catheter laboratory measures of coronary physiology from that TVECA, namely one or a combination of FFR, CFR, HSR and HMR, will correlate with the SPY® data on myocardial perfusion, and suggest a potential mechanism for this physiologic response to TVECA grafting.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
North Carolina
-
Greenville, North Carolina, Stati Uniti, 27834
- East Carolina Heart Institute at Vidant Medical Center
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Age >18<80
- Patients with stable angina or NSTEMI with total CK rise of <1000 U/litre who after planned coronary angiography are going to be referred for CABG and have at least one vessel with a visual 40-80% stenosis that is interrogated with intracoronary physiology
Exclusion Criteria:
- Emergent status, or Cardiogenic shock
- LVEF <40%
- History of actively malignant disease
- Patient needing concomitant valvular surgery or other cardiac structural reconstructive surgery
- As is standard of care, those vessels that are extremely tortuous, very small caliber and/or heavily calcified would not have such wires passed down them. Furthermore, those vessels that are 80-90+% stenosed, with <TIMI 3 flow, which we would not normally pass a diagnostic physiology pressure wire, would not be studied with ComboXT wire.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Diagnostico
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Altro: Patients referred for CABG
|
Intracoronary pressure and flow measurements
FDA approved use of injection of indocyanine green for the purposes of performing pre and post coronary grafting graft patency and perfusion assessment with the SPY near infra red fluorescence system
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Correlation Analysis
Lasso di tempo: 18 months
|
Correlation between anatomy, functional anatomy, FFR, SPY® RMP change, and the presence or absence of imaged competitive flow
|
18 months
|
Altre misure di risultato
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Correlation Analysis
Lasso di tempo: 18 months
|
Correlation analysis between anatomy, functional anatomy, FFR, CFR, HMR and SPY® perfusion data for each TVECA and perfusion territory.
|
18 months
|
|
Instantaneous Wave Free Ratio (iFR)
Lasso di tempo: 18 months
|
Offline analysis of de-identified encrypted data for each TVECA interrogated with ComboMap XT wire by Dr Justin Davies's research group, Imperial College, London for iFR determination.
Correlation analysis between iFR and presence or absence of imaged competitive flow and intra-operative RMP data on SPY® NIRF
|
18 months
|
|
Wave Intensity Analysis (WIA)
Lasso di tempo: 18 months
|
Offline wave wave intensity analysis (WIA) of de-identified encrypted data for each TVECA interrogated with ComboMap XT wire by Dr Justin Davies's research group, Imperial College, London.
Correlation analysis between WIA data and presence or absence of imaged competitive flow and intra-operative RMP data on SPY® NIRF
|
18 months
|
Collaboratori e investigatori
Sponsor
Investigatori
- Investigatore principale: Ashesh N Buch, MBChB, MD, East Carolina University
- Investigatore principale: T. Bruce Ferguson, MD, East Carolina University
Studiare le date dei record
Studia le date principali
Inizio studio
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- UMCIRB 13-001949
- PERSEUS I (Altro numero di sovvenzione/finanziamento: Volcano Corporation 120313)
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Disfunsione dell'arteria coronaria
-
I.R.C.C.S Ospedale Galeazzi-Sant'AmbrogioReclutamentoCoronary Artery DiseaseItalia
-
Tel-Aviv Sourasky Medical CenterCompletatoSoggetti consecutivi che sono idonei per una coronaria | Angioplastica di de Novo Lesion(s) in Native Coronary | Le arterie dovrebbero essere sottoposte a screening per l'idoneità. | Un numero totale di 200 pazienti che soddisfano la selezione | Criteri e disponibilità a firmare il consenso... e altre condizioniIsraele
Prove cliniche su ComboMap XT Guidewire
-
Medtronic Cardiac Rhythm and Heart FailureMedtronic Bakken Research CenterCompletatoAttacco ischemico transitorio sintomatico criptogenetico | Ictus ischemico criptogeneticoOlanda, Stati Uniti, Francia, Belgio, Germania, Svezia, Italia, Austria, Canada, Danimarca, Finlandia, Grecia, Slovacchia, Spagna
-
Tissue Regenix LtdReclutamento
-
Institut für Pharmakologie und Präventive MedizinEstimate, GmbHCompletatoMalfunzionamento della valvola polmonareBelgio, Canada, Svizzera
-
Xalud Therapeutics, Inc.CompletatoArtrosi, ginocchioStati Uniti
-
Edwards LifesciencesCompletatoStenosi della valvola aorticaGiappone
-
Lawson Health Research InstituteRitirato
-
Kennemer GasthuisMedtronicSconosciutoArresto cardiacoOlanda
-
TRX OrthopedicsRitiratoLesioni al ginocchio | Ricostruzione del legamento crociato anteriore (LCA).Stati Uniti
-
Edwards LifesciencesCompletatoMalattie cardiache | Malattia cardiovascolare | Anomalie congenite | Difetti cardiaci, congeniti | Insufficienza della valvola polmonare | Stenosi della valvola polmonareStati Uniti
-
Xalud Therapeutics, Inc.CompletatoArtrosi, ginocchioAustralia, Stati Uniti