Correlation Study of Imaging Data Acquired During CABG With Data Acquired in the Cath Lab (PERSEUS)

23 augusti 2019 uppdaterad av: Dr Ashesh N. Buch, East Carolina University

Collaborative Pilot Study to Determine the Correlation Between Intra-Operative Observations Using SPY® Near Infra-Red Imaging and Cardiac Catheterization Laboratory Physiological Assessment of Lesion Severity (PERSEUS Pilot Study)

Visual assessment of a coronary artery narrowing (called stenosis) seen on angiography is conventionally used to infer how likely the stenosis will limit blood flow (called ischemia) under conditions of increased demand (e.g exercise). This is based on animal work and data from humans with simple single vessel disease with no co-existing conditions. These data have been extrapolated to more complex patients/ complex disease but clearly over-simplifies the situation in the majority of patients cardiologists treat.

Pivotal work by DeBruyne, Pils and colleagues in the 90's convincingly showed that pressure derived measurements, called FFR, from the coronary artery during a cardiac catheterization, more accurately identify stenoses that would cause ischemia compared to visual assessment alone. A strategy of FFR guided coronary stenting with drug eluting stents significantly improved outcomes and reduced costs compared to visual assessment alone (FAME trial). Deferring treatment based on FFR has been shown to be safe (DEFER Trial). FFR has excellent sensitivity and specificity. A FFR of <=0.80 was used as this identified ischemia causing lesions 90% of the time. Therefore, the concept of FFR guided percutaneous revascularisation and treatment deferral has a robust evidence base to support it.

Coronary bypass grafting (CABG) is traditionally based solely on a visual assessment of angiography images. SPY® Infrared Fluorescence Angiography (NIRF, FDA approved 2005) is used by some cardiac surgeons to assess the patency of bypass grafts in real-time in the operating room, as a surrogate for immediate traditional coronary angiography. Dr. Ferguson observed that regional myocardial perfusion (RMP) image data was also captured in these video sequences.

Study Hypotheses:

  1. In patients who are likely CABG candidates, target vessel epicardial coronary arteries (TVECAs) with FFR > 0.80 will not demonstrate an increase in RMP despite an anatomically patent bypass conduit during SPY® imaging.
  2. In TVECAs with an increase in RMP during SPY® imaging, cardiac catheter laboratory measures of coronary physiology from that TVECA, namely one or a combination of FFR, CFR, HSR and HMR, will correlate with the SPY® data on myocardial perfusion, and suggest a potential mechanism for this physiologic response to TVECA grafting.

Studieöversikt

Studietyp

Interventionell

Inskrivning (Faktisk)

1

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

    • North Carolina
      • Greenville, North Carolina, Förenta staterna, 27834
        • East Carolina Heart Institute at Vidant Medical Center

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

18 år till 80 år (Vuxen, Äldre vuxen)

Tar emot friska volontärer

Nej

Kön som är behöriga för studier

Allt

Beskrivning

Inclusion Criteria:

  • Age >18<80
  • Patients with stable angina or NSTEMI with total CK rise of <1000 U/litre who after planned coronary angiography are going to be referred for CABG and have at least one vessel with a visual 40-80% stenosis that is interrogated with intracoronary physiology

Exclusion Criteria:

  • Emergent status, or Cardiogenic shock
  • LVEF <40%
  • History of actively malignant disease
  • Patient needing concomitant valvular surgery or other cardiac structural reconstructive surgery
  • As is standard of care, those vessels that are extremely tortuous, very small caliber and/or heavily calcified would not have such wires passed down them. Furthermore, those vessels that are 80-90+% stenosed, with <TIMI 3 flow, which we would not normally pass a diagnostic physiology pressure wire, would not be studied with ComboXT wire.

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Diagnostisk
  • Tilldelning: N/A
  • Interventionsmodell: Enskild gruppuppgift
  • Maskning: Ingen (Open Label)

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Övrig: Patients referred for CABG
  • Patients who after undergoing standard of care diagnostic coronary angiography will be referred for CABG
  • ComboMap XT Guidewire
  • 'SPY' NIRF During CABG
Intracoronary pressure and flow measurements
FDA approved use of injection of indocyanine green for the purposes of performing pre and post coronary grafting graft patency and perfusion assessment with the SPY near infra red fluorescence system

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Correlation Analysis
Tidsram: 18 months
Correlation between anatomy, functional anatomy, FFR, SPY® RMP change, and the presence or absence of imaged competitive flow
18 months

Andra resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Correlation Analysis
Tidsram: 18 months
Correlation analysis between anatomy, functional anatomy, FFR, CFR, HMR and SPY® perfusion data for each TVECA and perfusion territory.
18 months
Instantaneous Wave Free Ratio (iFR)
Tidsram: 18 months
Offline analysis of de-identified encrypted data for each TVECA interrogated with ComboMap XT wire by Dr Justin Davies's research group, Imperial College, London for iFR determination. Correlation analysis between iFR and presence or absence of imaged competitive flow and intra-operative RMP data on SPY® NIRF
18 months
Wave Intensity Analysis (WIA)
Tidsram: 18 months
Offline wave wave intensity analysis (WIA) of de-identified encrypted data for each TVECA interrogated with ComboMap XT wire by Dr Justin Davies's research group, Imperial College, London. Correlation analysis between WIA data and presence or absence of imaged competitive flow and intra-operative RMP data on SPY® NIRF
18 months

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Utredare

  • Huvudutredare: Ashesh N Buch, MBChB, MD, East Carolina University
  • Huvudutredare: T. Bruce Ferguson, MD, East Carolina University

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart

1 december 2014

Primärt slutförande (Faktisk)

30 mars 2018

Avslutad studie (Faktisk)

30 mars 2019

Studieregistreringsdatum

Först inskickad

12 maj 2014

Först inskickad som uppfyllde QC-kriterierna

12 maj 2014

Första postat (Uppskatta)

14 maj 2014

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

28 augusti 2019

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

23 augusti 2019

Senast verifierad

1 augusti 2019

Mer information

Termer relaterade till denna studie

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Ja

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .