- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT02138305
Correlation Study of Imaging Data Acquired During CABG With Data Acquired in the Cath Lab (PERSEUS)
Collaborative Pilot Study to Determine the Correlation Between Intra-Operative Observations Using SPY® Near Infra-Red Imaging and Cardiac Catheterization Laboratory Physiological Assessment of Lesion Severity (PERSEUS Pilot Study)
Visual assessment of a coronary artery narrowing (called stenosis) seen on angiography is conventionally used to infer how likely the stenosis will limit blood flow (called ischemia) under conditions of increased demand (e.g exercise). This is based on animal work and data from humans with simple single vessel disease with no co-existing conditions. These data have been extrapolated to more complex patients/ complex disease but clearly over-simplifies the situation in the majority of patients cardiologists treat.
Pivotal work by DeBruyne, Pils and colleagues in the 90's convincingly showed that pressure derived measurements, called FFR, from the coronary artery during a cardiac catheterization, more accurately identify stenoses that would cause ischemia compared to visual assessment alone. A strategy of FFR guided coronary stenting with drug eluting stents significantly improved outcomes and reduced costs compared to visual assessment alone (FAME trial). Deferring treatment based on FFR has been shown to be safe (DEFER Trial). FFR has excellent sensitivity and specificity. A FFR of <=0.80 was used as this identified ischemia causing lesions 90% of the time. Therefore, the concept of FFR guided percutaneous revascularisation and treatment deferral has a robust evidence base to support it.
Coronary bypass grafting (CABG) is traditionally based solely on a visual assessment of angiography images. SPY® Infrared Fluorescence Angiography (NIRF, FDA approved 2005) is used by some cardiac surgeons to assess the patency of bypass grafts in real-time in the operating room, as a surrogate for immediate traditional coronary angiography. Dr. Ferguson observed that regional myocardial perfusion (RMP) image data was also captured in these video sequences.
Study Hypotheses:
- In patients who are likely CABG candidates, target vessel epicardial coronary arteries (TVECAs) with FFR > 0.80 will not demonstrate an increase in RMP despite an anatomically patent bypass conduit during SPY® imaging.
- In TVECAs with an increase in RMP during SPY® imaging, cardiac catheter laboratory measures of coronary physiology from that TVECA, namely one or a combination of FFR, CFR, HSR and HMR, will correlate with the SPY® data on myocardial perfusion, and suggest a potential mechanism for this physiologic response to TVECA grafting.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
North Carolina
-
Greenville, North Carolina, Estados Unidos, 27834
- East Carolina Heart Institute at Vidant Medical Center
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Age >18<80
- Patients with stable angina or NSTEMI with total CK rise of <1000 U/litre who after planned coronary angiography are going to be referred for CABG and have at least one vessel with a visual 40-80% stenosis that is interrogated with intracoronary physiology
Exclusion Criteria:
- Emergent status, or Cardiogenic shock
- LVEF <40%
- History of actively malignant disease
- Patient needing concomitant valvular surgery or other cardiac structural reconstructive surgery
- As is standard of care, those vessels that are extremely tortuous, very small caliber and/or heavily calcified would not have such wires passed down them. Furthermore, those vessels that are 80-90+% stenosed, with <TIMI 3 flow, which we would not normally pass a diagnostic physiology pressure wire, would not be studied with ComboXT wire.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Diagnóstico
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Otro: Patients referred for CABG
|
Intracoronary pressure and flow measurements
FDA approved use of injection of indocyanine green for the purposes of performing pre and post coronary grafting graft patency and perfusion assessment with the SPY near infra red fluorescence system
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Correlation Analysis
Periodo de tiempo: 18 months
|
Correlation between anatomy, functional anatomy, FFR, SPY® RMP change, and the presence or absence of imaged competitive flow
|
18 months
|
Otras medidas de resultado
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Correlation Analysis
Periodo de tiempo: 18 months
|
Correlation analysis between anatomy, functional anatomy, FFR, CFR, HMR and SPY® perfusion data for each TVECA and perfusion territory.
|
18 months
|
|
Instantaneous Wave Free Ratio (iFR)
Periodo de tiempo: 18 months
|
Offline analysis of de-identified encrypted data for each TVECA interrogated with ComboMap XT wire by Dr Justin Davies's research group, Imperial College, London for iFR determination.
Correlation analysis between iFR and presence or absence of imaged competitive flow and intra-operative RMP data on SPY® NIRF
|
18 months
|
|
Wave Intensity Analysis (WIA)
Periodo de tiempo: 18 months
|
Offline wave wave intensity analysis (WIA) of de-identified encrypted data for each TVECA interrogated with ComboMap XT wire by Dr Justin Davies's research group, Imperial College, London.
Correlation analysis between WIA data and presence or absence of imaged competitive flow and intra-operative RMP data on SPY® NIRF
|
18 months
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Ashesh N Buch, MBChB, MD, East Carolina University
- Investigador principal: T. Bruce Ferguson, MD, East Carolina University
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- UMCIRB 13-001949
- PERSEUS I (Otro número de subvención/financiamiento: Volcano Corporation 120313)
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .