- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT02724709
Semi-automatic assessMent of Aortic Roots by Three-dimensional transoEsophageal echocaRdiography (SMARTER)
8. srpna 2016 aktualizováno: Bin Lu, Chinese Academy of Medical Sciences, Fuwai Hospital
The progress in surgery of the aortic root and the evolution of transcatheter aortic valve replacement as an alternative to surgical treatment in selected patients have refocused the need for quantitative imaging of the aortic root during transcatheter aortic valve replacement and valve-sparing aortic root surgery.
In this study, we aim to assess the ability of semi-automated quantitative modeling (eSie Valves, Autovalve prototype version, Siemens Medical Solutions, USA) of the aortic valve and root in patients with clinical normal aortic valve and root, who are indicated for both 3D transesophageal echocardiography (TEE) and computed tomographic (CT) due to atrial fibrillation or patent foramen ovale.
Measures of the aortic valve and root obtained by 2D TEE, 3D TEE and CT are compared, and the ability of the semi-automated 3D TEE modeling software is tested.
Given the workflow advantages of automation, this 3D TEE approach may enhance the clinical adoption of routine 3-dimensional imaging beyond CT.
Přehled studie
Postavení
Dokončeno
Podmínky
Detailní popis
Recent developments in aortic root interventions have focused on the need for 3-dimensional imaging of the aortic functional anatomy.
The progress in surgery of the aortic root and the evolution of transcatheter aortic valve replacement as an alternative to surgical treatment in selected patients have refocused the need for quantitative imaging of the aortic root during transcatheter aortic valve replacement and valve-sparing aortic root surgery.
In this study, we aim to assess the ability of semi-automated quantitative modeling (eSie Valves, Autovalve prototype version, Siemens Medical Solutions, USA) of the aortic valve and root in patients with clinical normal aortic valve and root, who are indicated for both 3D transesophageal echocardiography (TEE) and computed tomographic (CT) due to atrial fibrillation or patent foramen ovale.
Measures of the aortic valve and root obtained by 2D TEE, 3D TEE and CT are compared, and the ability of the semi-automated 3D TEE modeling software is tested.
Given the workflow advantages of automation, this 3D TEE approach may enhance the clinical adoption of routine 3-dimensional imaging beyond CT.
Typ studie
Pozorovací
Zápis (Aktuální)
77
Kontakty a umístění
Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.
Studijní místa
-
-
Beijing
-
Beijing, Beijing, Čína, 100037
- Fuwai Hospital
-
-
Kritéria účasti
Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.
Kritéria způsobilosti
Věk způsobilý ke studiu
18 let až 75 let (Dospělý, Starší dospělý)
Přijímá zdravé dobrovolníky
Ne
Pohlaví způsobilá ke studiu
Všechno
Metoda odběru vzorků
Vzorek nepravděpodobnosti
Studijní populace
Patients with clinical normal aortic valve and root, who are indicated for both transesophageal echocardiography (TEE) and computed tomographic (CT) due to atrial fibrillation or patent foramen ovale.
Popis
Inclusion Criteria:
- both transesophageal echocardiography (TEE) and computed tomographic (CT) are referred by cardiologists
- apparent normal aortic valve and root structure
- written consent
Exclusion Criteria:
- post-operation of aortic valve
- severe cardiomyopathy
- cardiac functional insufficiency (NYHA III or IV)
- contraindications for either TEE or cardiac CT angiography
Studijní plán
Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.
Jak je studie koncipována?
Detaily designu
- Observační modely: Pouze případ
- Časové perspektivy: Budoucí
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Accuracy
Časové okno: Through study completion, an average of 1 month
|
Compare semi-automatic assessment of 3D TEE to CT measurement
|
Through study completion, an average of 1 month
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Cost
Časové okno: Through study completion, an average of 1 month
|
Compare cost between 3D TEE and CT
|
Through study completion, an average of 1 month
|
|
Labor time
Časové okno: Through study completion, an average of 1 month
|
Compare labor time between 3D TEE and CT
|
Through study completion, an average of 1 month
|
Spolupracovníci a vyšetřovatelé
Zde najdete lidi a organizace zapojené do této studie.
Spolupracovníci
Vyšetřovatelé
- Studijní židle: Hao Wang, M.D., Fuwai Hospital
Publikace a užitečné odkazy
Osoba odpovědná za zadávání informací o studiu tyto publikace poskytuje dobrovolně. Mohou se týkat čehokoli, co souvisí se studiem.
Obecné publikace
- Garcia-Martin A, Lazaro-Rivera C, Fernandez-Golfin C, Salido-Tahoces L, Moya-Mur JL, Jimenez-Nacher JJ, Casas-Rojo E, Aquila I, Gonzalez-Gomez A, Hernandez-Antolin R, Zamorano JL. Accuracy and reproducibility of novel echocardiographic three-dimensional automated software for the assessment of the aortic root in candidates for thanscatheter aortic valve replacement. Eur Heart J Cardiovasc Imaging. 2016 Jul;17(7):772-8. doi: 10.1093/ehjci/jev204. Epub 2015 Aug 27.
- Calleja A, Thavendiranathan P, Ionasec RI, Houle H, Liu S, Voigt I, Sai Sudhakar C, Crestanello J, Ryan T, Vannan MA. Automated quantitative 3-dimensional modeling of the aortic valve and root by 3-dimensional transesophageal echocardiography in normals, aortic regurgitation, and aortic stenosis: comparison to computed tomography in normals and clinical implications. Circ Cardiovasc Imaging. 2013 Jan 1;6(1):99-108. doi: 10.1161/CIRCIMAGING.112.976993. Epub 2012 Dec 10.
- Chambers JB, Myerson SG, Rajani R, Morgan-Hughes GJ, Dweck MR. Multimodality imaging in heart valve disease. Open Heart. 2016 Mar 8;3(1):e000330. doi: 10.1136/openhrt-2015-000330. eCollection 2016.
- Hahn RT, Little SH, Monaghan MJ, Kodali SK, Williams M, Leon MB, Gillam LD. Recommendations for comprehensive intraprocedural echocardiographic imaging during TAVR. JACC Cardiovasc Imaging. 2015 Mar;8(3):261-287. doi: 10.1016/j.jcmg.2014.12.014.
- Zhang M, Wan L, Liu K, Wu W, Li H, Wang Y, Lu B, Wang H. Aortic roots assessment by an automated three-dimensional transesophageal echocardiography: an intra-individual comparison. Int J Cardiovasc Imaging. 2019 Nov;35(11):2029-2036. doi: 10.1007/s10554-019-01664-z. Epub 2019 Jul 11.
Termíny studijních záznamů
Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.
Hlavní termíny studia
Začátek studia
1. března 2016
Primární dokončení (Aktuální)
1. července 2016
Dokončení studie (Aktuální)
1. srpna 2016
Termíny zápisu do studia
První předloženo
21. března 2016
První předloženo, které splnilo kritéria kontroly kvality
25. března 2016
První zveřejněno (Odhad)
31. března 2016
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Odhad)
9. srpna 2016
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
8. srpna 2016
Naposledy ověřeno
1. srpna 2016
Více informací
Termíny související s touto studií
Další relevantní podmínky MeSH
Další identifikační čísla studie
- 2016-096
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Ano
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .