Semi-automatic assessMent of Aortic Roots by Three-dimensional transoEsophageal echocaRdiography (SMARTER)

8 augustus 2016 bijgewerkt door: Bin Lu, Chinese Academy of Medical Sciences, Fuwai Hospital
The progress in surgery of the aortic root and the evolution of transcatheter aortic valve replacement as an alternative to surgical treatment in selected patients have refocused the need for quantitative imaging of the aortic root during transcatheter aortic valve replacement and valve-sparing aortic root surgery. In this study, we aim to assess the ability of semi-automated quantitative modeling (eSie Valves, Autovalve prototype version, Siemens Medical Solutions, USA) of the aortic valve and root in patients with clinical normal aortic valve and root, who are indicated for both 3D transesophageal echocardiography (TEE) and computed tomographic (CT) due to atrial fibrillation or patent foramen ovale. Measures of the aortic valve and root obtained by 2D TEE, 3D TEE and CT are compared, and the ability of the semi-automated 3D TEE modeling software is tested. Given the workflow advantages of automation, this 3D TEE approach may enhance the clinical adoption of routine 3-dimensional imaging beyond CT.

Studie Overzicht

Gedetailleerde beschrijving

Recent developments in aortic root interventions have focused on the need for 3-dimensional imaging of the aortic functional anatomy. The progress in surgery of the aortic root and the evolution of transcatheter aortic valve replacement as an alternative to surgical treatment in selected patients have refocused the need for quantitative imaging of the aortic root during transcatheter aortic valve replacement and valve-sparing aortic root surgery. In this study, we aim to assess the ability of semi-automated quantitative modeling (eSie Valves, Autovalve prototype version, Siemens Medical Solutions, USA) of the aortic valve and root in patients with clinical normal aortic valve and root, who are indicated for both 3D transesophageal echocardiography (TEE) and computed tomographic (CT) due to atrial fibrillation or patent foramen ovale. Measures of the aortic valve and root obtained by 2D TEE, 3D TEE and CT are compared, and the ability of the semi-automated 3D TEE modeling software is tested. Given the workflow advantages of automation, this 3D TEE approach may enhance the clinical adoption of routine 3-dimensional imaging beyond CT.

Studietype

Observationeel

Inschrijving (Werkelijk)

77

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Beijing
      • Beijing, Beijing, China, 100037
        • Fuwai Hospital

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

18 jaar tot 75 jaar (Volwassen, Oudere volwassene)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Bemonsteringsmethode

Niet-waarschijnlijkheidssteekproef

Studie Bevolking

Patients with clinical normal aortic valve and root, who are indicated for both transesophageal echocardiography (TEE) and computed tomographic (CT) due to atrial fibrillation or patent foramen ovale.

Beschrijving

Inclusion Criteria:

  • both transesophageal echocardiography (TEE) and computed tomographic (CT) are referred by cardiologists
  • apparent normal aortic valve and root structure
  • written consent

Exclusion Criteria:

  • post-operation of aortic valve
  • severe cardiomyopathy
  • cardiac functional insufficiency (NYHA III or IV)
  • contraindications for either TEE or cardiac CT angiography

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Observatiemodellen: Case-Alleen
  • Tijdsperspectieven: Prospectief

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Accuracy
Tijdsspanne: Through study completion, an average of 1 month
Compare semi-automatic assessment of 3D TEE to CT measurement
Through study completion, an average of 1 month

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Cost
Tijdsspanne: Through study completion, an average of 1 month
Compare cost between 3D TEE and CT
Through study completion, an average of 1 month
Labor time
Tijdsspanne: Through study completion, an average of 1 month
Compare labor time between 3D TEE and CT
Through study completion, an average of 1 month

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Studie stoel: Hao Wang, M.D., Fuwai Hospital

Publicaties en nuttige links

De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.

Algemene publicaties

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start

1 maart 2016

Primaire voltooiing (Werkelijk)

1 juli 2016

Studie voltooiing (Werkelijk)

1 augustus 2016

Studieregistratiedata

Eerst ingediend

21 maart 2016

Eerst ingediend dat voldeed aan de QC-criteria

25 maart 2016

Eerst geplaatst (Schatting)

31 maart 2016

Updates van studierecords

Laatste update geplaatst (Schatting)

9 augustus 2016

Laatste update ingediend die voldeed aan QC-criteria

8 augustus 2016

Laatst geverifieerd

1 augustus 2016

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

Ja

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .